Optimal Protocol for Contrast-enhanced Free-running 5D Whole-heart Coronary MR Angiography at 3T

被引:7
|
作者
Ishida, Masaki [1 ]
Yerly, Jerome [2 ,3 ,4 ]
Ito, Haruno [1 ]
Takafuji, Masafumi [1 ]
Nakamori, Shiro [5 ]
Takase, Shinichi [1 ]
Ichiba, Yoshito [6 ]
Komori, Yoshiaki [6 ]
Dohi, Kaoru [5 ]
Piccini, Davide [2 ,3 ,4 ,7 ]
Bastiaansen, Jessica A. M. [2 ,3 ,4 ,8 ]
Stuber, Matthias [2 ,3 ,4 ]
Sakuma, Hajime [1 ]
机构
[1] Mie Univ Hosp, Dept Radiol, 2-174 Edobashi, Tsu, Mie 5148507, Japan
[2] Lausanne Univ Hosp CHUV, Dept Diagnost & Intervent Radiol, Lausanne, Switzerland
[3] Univ Lausanne UNIL, Lausanne, Switzerland
[4] Ctr Biomed Imaging CIBM, Lausanne, Switzerland
[5] Mie Univ Hosp, Dept Cardiol, Tsu, Mie, Japan
[6] Siemens Healthcare KK, Tokyo, Japan
[7] Siemens Healthcare AG, Adv Clin Imaging Technol, Lausanne, Switzerland
[8] Univ Bern, Dept Diagnost Intervent & Pediat Radiol DIPR, Inselspital Bern Univ Hosp, Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
contrast medium; coronary Magnetic Resonance angiography; fat suppression; free-running framework; gradient echo; VISUALIZATION;
D O I
10.2463/mrms.tn.2022-0086
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Free-running 5D whole-heart coronary MR angiography (MRA) is gaining in popularity because it reduces scanning complexity by removing the need for specific slice orientations, respiratory gating, or cardiac triggering. At 3T, a gradient echo (GRE) sequence is preferred in combination with contrast injection. However, neither the injection scheme of the gadolinium (Gd) contrast medium, the choice of the RF excitation angle, nor the dedicated image reconstruction parameters have been established for 3T GRE free-running 5D whole-heart coronary MRA. In this study, a Gd injection scheme, RF excitation angles of lipid-insensitive binominal off-resonance RF excitation (LIBRE) pulse for valid fat suppression and continuous data acquisition, and compressed-sensing reconstruction regularization parameters were optimized for contrast-enhanced free-running 5D whole-heart coronary MRA using a GRE sequence at 3T. Using this optimized protocol, contrast-enhanced free-running 5D whole-heart coronary MRA using a GRE sequence is feasible with good image quality at 3T.
引用
收藏
页码:225 / 237
页数:13
相关论文
共 50 条
  • [41] Profile Order and Time-Dependent Artifacts in Contrast-Enhanced Coronary MR Angiography at 3T: Origin and Prevention
    Kotys, Melanie S.
    Herzka, Daniel A.
    Vonken, Evert-Jan
    Ohayon, Jacques
    Heroux, Julie
    Gharib, Ahmed M.
    Stuber, Matthias
    Pettigrew, Roderic I.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (02) : 292 - 299
  • [42] Contrast-enhanced whole-heart coronary MRA at 3.0T for the evaluation of cardiac venous anatomy
    Ma, Heng
    Tang, Qing
    Yang, Qi
    Bi, Xiaoming
    Li, Han
    Ge, Lan
    Lin, Kai
    Xu, Dong
    Du, Xiangying
    Lu, Jie
    An, Jing
    Jin, Lixin
    Jerecic, Renate
    Li, Kuncheng
    Li, Debiao
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07): : 1003 - 1009
  • [43] Whole-heart contrast-enhanced coronary magnetic resonance angiography in less than 5 minutes using gradient echo interleaved EPI
    Himanshu Bhat
    Sven Zuehlsdorff
    Xiaoming Bi
    Xin Liu
    Renate Jerecic
    Debiao Li
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [44] Contrast-enhanced whole-heart coronary MRA at 3.0T for the evaluation of cardiac venous anatomy
    Heng Ma
    Qing Tang
    Qi Yang
    Xiaoming Bi
    Han Li
    Lan Ge
    Kai Lin
    Dong Xu
    Xiangying Du
    Jie Lu
    Jing An
    Lixin Jin
    Renate Jerecic
    Kuncheng Li
    Debiao Li
    The International Journal of Cardiovascular Imaging, 2011, 27 : 1003 - 1009
  • [45] 3D coronary MR angiography at 1.5 T: Volume-targeted versus whole-heart acquisition
    Jin, Hang
    Zeng, Meng-Su
    Ge, Mei-Ying
    Yun, Hong
    Yang, Shan
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (03) : 594 - 602
  • [46] Whole heart 3 D MR coronary angiography with and without extracellular contrast agent
    Dorota Piotrowska-Kownacka
    Lukasz Kownacki
    Grzegorz Opolski
    Leszek Krolicki
    Olgierd Rowinski
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [47] Follow-up of coiled cerebral aneurysms at 3T: Comparison of 3D time-of-flight MR angiography and contrast-enhanced MR angiography
    Anzalone, N.
    Scomazzoni, F.
    Cirillo, M.
    Righi, C.
    Simionato, F.
    Cadioli, M.
    Iadanza, A.
    Kirchin, M. A.
    Scotti, G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (08) : 1530 - 1536
  • [48] Accelerated time-resolved 3D contrast-enhanced MR angiography at 3T: clinical experience in 31 patients
    Frydrychowicz, Alex
    Bley, Thorsten A.
    Winterer, Jan T.
    Harloff, Andreas
    Langer, Mathias
    Hennig, Juergen
    Markl, Michael
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2006, 19 (04) : 187 - 195
  • [49] Accelerated time-resolved 3D contrast-enhanced MR angiography at 3T: clinical experience in 31 patients
    Alex Frydrychowicz
    Thorsten A. Bley
    Jan T. Winterer
    Andreas Harloff
    Mathias Langer
    Jürgen Hennig
    Michael Markl
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2006, 19 : 187 - 195
  • [50] A study of in vitro and in vivo MR of free-breathing whole-heart 3D coronary angiography using parallel imaging
    Jin, Hang
    Zeng, Meng-Su
    Ge, Mei-Ying
    Yang, Shan
    Chen, Cai-Zhong
    Shen, Ji-Zhang
    Li, Ren-Chen
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 : 121 - 129