Optimal Protocol for Contrast-enhanced Free-running 5D Whole-heart Coronary MR Angiography at 3T

被引:7
|
作者
Ishida, Masaki [1 ]
Yerly, Jerome [2 ,3 ,4 ]
Ito, Haruno [1 ]
Takafuji, Masafumi [1 ]
Nakamori, Shiro [5 ]
Takase, Shinichi [1 ]
Ichiba, Yoshito [6 ]
Komori, Yoshiaki [6 ]
Dohi, Kaoru [5 ]
Piccini, Davide [2 ,3 ,4 ,7 ]
Bastiaansen, Jessica A. M. [2 ,3 ,4 ,8 ]
Stuber, Matthias [2 ,3 ,4 ]
Sakuma, Hajime [1 ]
机构
[1] Mie Univ Hosp, Dept Radiol, 2-174 Edobashi, Tsu, Mie 5148507, Japan
[2] Lausanne Univ Hosp CHUV, Dept Diagnost & Intervent Radiol, Lausanne, Switzerland
[3] Univ Lausanne UNIL, Lausanne, Switzerland
[4] Ctr Biomed Imaging CIBM, Lausanne, Switzerland
[5] Mie Univ Hosp, Dept Cardiol, Tsu, Mie, Japan
[6] Siemens Healthcare KK, Tokyo, Japan
[7] Siemens Healthcare AG, Adv Clin Imaging Technol, Lausanne, Switzerland
[8] Univ Bern, Dept Diagnost Intervent & Pediat Radiol DIPR, Inselspital Bern Univ Hosp, Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
contrast medium; coronary Magnetic Resonance angiography; fat suppression; free-running framework; gradient echo; VISUALIZATION;
D O I
10.2463/mrms.tn.2022-0086
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Free-running 5D whole-heart coronary MR angiography (MRA) is gaining in popularity because it reduces scanning complexity by removing the need for specific slice orientations, respiratory gating, or cardiac triggering. At 3T, a gradient echo (GRE) sequence is preferred in combination with contrast injection. However, neither the injection scheme of the gadolinium (Gd) contrast medium, the choice of the RF excitation angle, nor the dedicated image reconstruction parameters have been established for 3T GRE free-running 5D whole-heart coronary MRA. In this study, a Gd injection scheme, RF excitation angles of lipid-insensitive binominal off-resonance RF excitation (LIBRE) pulse for valid fat suppression and continuous data acquisition, and compressed-sensing reconstruction regularization parameters were optimized for contrast-enhanced free-running 5D whole-heart coronary MRA using a GRE sequence at 3T. Using this optimized protocol, contrast-enhanced free-running 5D whole-heart coronary MRA using a GRE sequence is feasible with good image quality at 3T.
引用
收藏
页码:225 / 237
页数:13
相关论文
共 50 条
  • [21] Intracranial time-resolved contrast-enhanced MR angiography at 3T
    Cashen, TA
    Carr, JC
    Shin, W
    Walker, MT
    Futterer, SF
    Shaibani, A
    McCarthy, FM
    Carroll, TJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (04) : 822 - 829
  • [22] Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0 T - Comparison with steady-state free precession technique at 1.5 T
    Liu, Xin
    Bi, Xiaoming
    Huang, Jie
    Jerecic, Renate
    Carr, James
    Li, Debiao
    INVESTIGATIVE RADIOLOGY, 2008, 43 (09) : 663 - 668
  • [23] Evaluation of Dural Arteriovenous Fistulas with 4D Contrast-Enhanced MR Angiography at 3T
    Nishimura, S.
    Hirai, T.
    Sasao, A.
    Kitajima, M.
    Morioka, M.
    Kai, Y.
    Omori, Y.
    Okuda, T.
    Murakami, R.
    Fukuoka, H.
    Awai, K.
    Kuratsu, J. -I.
    Yamashita, Y.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (01) : 80 - 85
  • [24] Whole-Heart Contrast-Enhanced Coronary Magnetic Resonance Angiography Using Gradient Echo Interleaved EPI
    Bhat, Himanshu
    Zuehlsdorff, Sven
    Bi, Xiaoming
    Li, Debiao
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (06) : 1388 - 1395
  • [25] 102 Diagnostic value of contrast-enhanced whole-heart coronary MRA at 3 Tesla
    Qi Yang
    Debiao Li
    Xiaoming Bi
    Jing An
    Qiang Zhang
    Renate Jerecic
    Kuncheng Li
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [26] Carotid Artery Stenosis: Comparison of 3D Time-of-Flight MR Angiography and Contrast-Enhanced MR Angiography at 3T
    Platzek, Ivan
    Sieron, Dominik
    Wiggermann, Philipp
    Laniado, Michael
    RADIOLOGY RESEARCH AND PRACTICE, 2014, 2014
  • [27] Influence of Applying Nitroglycerin in Whole-Heart Free-Breathing 3D Coronary MR Angiography
    Jin, Hang
    Zeng, Meng-Su
    Ge, Mei-Ying
    Ma, Jian-Ying
    Chen, Cai-Zhong
    Shen, Ji-Zhang
    Li, Ren-Chen
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (04) : 927 - 932
  • [28] Comparison of free-running whole-heart 5D and 4D flow imaging to standard 2D phase contrast in patients with right-sided congenital heart disease
    Rutz, Tobias
    Estelle, Tenisch
    Falcao, Mariana
    Faessler, Sara
    Christopher, Roy
    David, Rodrigues
    Liliana, M. A.
    Markl, Michael
    Stuber, Matthias
    Piccini, Davide
    Schwitter, Juerg
    Prsa, Milan
    SWISS MEDICAL WEEKLY, 2023, 153 : 62S - 62S
  • [29] Contrast-Enhanced Whole-Heart Coronary MRA using Gadofosveset: 3.0 T versus 1.5 T
    Prompona, Maria
    Cyran, Clemens
    Nikolaou, Konstantin
    Bauner, Kerstin
    Reiser, Maximilian
    Huber, Armin
    ACADEMIC RADIOLOGY, 2010, 17 (07) : 862 - 870
  • [30] Self-Tracking of Contrast Kinetics for Automatic Triggering of Contrast-Enhanced Whole-Heart Coronary Magnetic Resonance Angiography
    Bhat, Himanshu
    Lai, Peng
    Li, Debiao
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (04) : 809 - 816