Study on the optimal solution recirculation ratio of liquid desiccant dehumidification system based on matching rate evaluation

被引:6
|
作者
Zhang, Guangkai [1 ]
Xie, Jingchao [1 ]
Ji, Ying [1 ]
Du, Boyao [1 ]
Liu, Honggang [1 ]
Liu, Jiaping [1 ]
机构
[1] Beijing Univ Technol, Key Lab Green Built Environm & Energy Efficient Te, Beijing 100124, Peoples R China
基金
中国国家自然科学基金;
关键词
Solution recirculation ratio; Dehumidification; Matching; Liquid desiccant; Air conditioning; AIR-CONDITIONING SYSTEM; MASS-TRANSFER CORRELATIONS; PERFORMANCE ANALYSIS; COOLING SYSTEM; FLOW; ENERGY; DEHUMIDIFIER/REGENERATOR; OPTIMIZATION; TEMPERATURE; COUNTER;
D O I
10.1016/j.applthermaleng.2023.121770
中图分类号
O414.1 [热力学];
学科分类号
摘要
The recirculation of dehumidification and regeneration solutions has shown promising moisture removal rates and energy-saving effects in liquid desiccant dehumidification systems. The different combinations of dehumidification solution recirculation ratio and regeneration solution recirculation ratio under varying operating conditions can have different impacts on the system. Nevertheless, the system performance under full operating conditions has not been comprehensively studied. To address this research gap, this study proposes a liquid desiccant dehumidification system with a solution recirculation structure, defines a new evaluation index - matching rate, and conducts a parameterized study and optimization of the steady-state performance of the liquid desiccant dehumidification system with a solution recirculation structure within the range of solution recirculation ratios under all operating conditions, by integrating the system cooling capacity and energy effectiveness ratio. The performance of the system is studied by varying seven key parameters: dehumidification solution recirculation ratio, regeneration solution recirculation ratio, total solution mass flow rate, dehumidification solution inlet temperature, regeneration solution inlet temperature, and ambient air temperaturehumidity ratio. The results show that under design conditions, the solution recirculation ratio within the full operating range can process air to a range of 17.8 degrees C-18.5 degrees C and 12.5 g/kg-17.4 g/kg. The maximum system cooling capacity, energy effectiveness ratio and matching rate values are 21.5 kW, 0.21 and 0.42 respectively. The recommended (dehumidification solution recirculation ratio, regeneration solution recirculation ratio) schemes for high, medium and low demand of system cooling capacity are (0.7-0.9, 0-0.5), (0.4-0.6, 0-0.7) and (0-0.3, 0.4-0.7) respectively, based on the requirements of system cooling capacity.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Modeling of liquid desiccant cooling and dehumidification system based on artificial neural network
    Ou, Xianhua
    Cai, Wenjian
    He, Xiongxiong
    Zhang, Xin
    IECON 2020: THE 46TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2020, : 4810 - 4814
  • [22] Membrane-based packed-sheet liquid desiccant dehumidification system
    Elsafi, Amin M.
    Bahrami, Majid
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [23] The experimental study of dehumidification and regeneration processes in a fin and tube liquid desiccant system
    Indrawan, Wisnu
    Lubis, Arnas
    Nasruddin
    Alhamid, M. I.
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 39
  • [24] Membrane-based packed-sheet liquid desiccant dehumidification system
    Elsafi, Amin M.
    Bahrami, Majid
    Bahrami, Majid (mbahrami@sfu.ca), 1600, Elsevier Ltd (236):
  • [25] An Experimental Study on Dehumidification Characteristics according to Operating Conditions of Liquid Desiccant System
    Jeon, Dong-Soon
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2024, 48 (11) : 737 - 744
  • [26] Performance assessment of a membrane liquid desiccant dehumidification cooling system based on experimental investigations
    Chen, Ziwei
    Zhu, Jie
    Bai, Hongyu
    ENERGY AND BUILDINGS, 2017, 139 : 665 - 679
  • [27] The design and experimental investigation of membrane-based tubular liquid desiccant dehumidification system
    Kavasogullari, Baris
    Cihan, Ertugrul
    Demir, Hasan
    PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, 2023, 29 (04): : 303 - 313
  • [28] Experimental study on partially internally cooled dehumidification in liquid desiccant air conditioning system
    Gao, W. Z.
    Shi, Y. R.
    Cheng, Y. P.
    Sun, W. Z.
    ENERGY AND BUILDINGS, 2013, 61 : 202 - 209
  • [29] Performance study of the internally-cooled ultrasonic atomization liquid desiccant dehumidification system
    Yang, Zili
    Tao, Ruiyang
    Ni, Hui
    Zhong, Ke
    Lian, Zhiwei
    ENERGY, 2019, 175 : 745 - 757
  • [30] Experimental study on mass transfer performances of the ultrasonic atomization liquid desiccant dehumidification system
    Yang, Zili
    Lin, Beibei
    Zhang, Kaisheng
    Lian, Zhiwei
    ENERGY AND BUILDINGS, 2015, 93 : 126 - 136