Study on the optimal solution recirculation ratio of liquid desiccant dehumidification system based on matching rate evaluation

被引:6
|
作者
Zhang, Guangkai [1 ]
Xie, Jingchao [1 ]
Ji, Ying [1 ]
Du, Boyao [1 ]
Liu, Honggang [1 ]
Liu, Jiaping [1 ]
机构
[1] Beijing Univ Technol, Key Lab Green Built Environm & Energy Efficient Te, Beijing 100124, Peoples R China
基金
中国国家自然科学基金;
关键词
Solution recirculation ratio; Dehumidification; Matching; Liquid desiccant; Air conditioning; AIR-CONDITIONING SYSTEM; MASS-TRANSFER CORRELATIONS; PERFORMANCE ANALYSIS; COOLING SYSTEM; FLOW; ENERGY; DEHUMIDIFIER/REGENERATOR; OPTIMIZATION; TEMPERATURE; COUNTER;
D O I
10.1016/j.applthermaleng.2023.121770
中图分类号
O414.1 [热力学];
学科分类号
摘要
The recirculation of dehumidification and regeneration solutions has shown promising moisture removal rates and energy-saving effects in liquid desiccant dehumidification systems. The different combinations of dehumidification solution recirculation ratio and regeneration solution recirculation ratio under varying operating conditions can have different impacts on the system. Nevertheless, the system performance under full operating conditions has not been comprehensively studied. To address this research gap, this study proposes a liquid desiccant dehumidification system with a solution recirculation structure, defines a new evaluation index - matching rate, and conducts a parameterized study and optimization of the steady-state performance of the liquid desiccant dehumidification system with a solution recirculation structure within the range of solution recirculation ratios under all operating conditions, by integrating the system cooling capacity and energy effectiveness ratio. The performance of the system is studied by varying seven key parameters: dehumidification solution recirculation ratio, regeneration solution recirculation ratio, total solution mass flow rate, dehumidification solution inlet temperature, regeneration solution inlet temperature, and ambient air temperaturehumidity ratio. The results show that under design conditions, the solution recirculation ratio within the full operating range can process air to a range of 17.8 degrees C-18.5 degrees C and 12.5 g/kg-17.4 g/kg. The maximum system cooling capacity, energy effectiveness ratio and matching rate values are 21.5 kW, 0.21 and 0.42 respectively. The recommended (dehumidification solution recirculation ratio, regeneration solution recirculation ratio) schemes for high, medium and low demand of system cooling capacity are (0.7-0.9, 0-0.5), (0.4-0.6, 0-0.7) and (0-0.3, 0.4-0.7) respectively, based on the requirements of system cooling capacity.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Model-based investigation of a heat pump driven, internally cooled liquid desiccant dehumidification system
    Liu, Jun
    Zhang, Tao
    Liu, Xiaohua
    BUILDING AND ENVIRONMENT, 2018, 143 : 431 - 442
  • [42] Investigation on capacity matching in a heat pump and hollow fiber membrane-based two-stage liquid desiccant hybrid air dehumidification system
    Zhang, Ning
    Yin, Shao-You
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 84 : 128 - 138
  • [43] A hybrid flue gas heat recovery system based on vapor compression refrigeration and liquid desiccant dehumidification
    Zhang, Xiaoyue
    Wu, Junda
    Li, Zhen
    Chen, Yongmei
    ENERGY CONVERSION AND MANAGEMENT, 2019, 195 : 157 - 166
  • [44] Performance evaluation of a heat pump-driven liquid desiccant dehumidification system integrated with fresh air supply
    Li, Wenzhang
    Yin, Yonggao
    Wang, Yikai
    ENERGY AND BUILDINGS, 2022, 275
  • [45] A heat pump driven and hollow fiber membrane-based liquid desiccant air dehumidification system: A transient performance study
    Zhang, Ning
    Zhang, Li-Zhi
    Xu, Jian-Chang
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 67 : 143 - 156
  • [46] Transient performance study of an internally-cooled plate membrane liquid desiccant air dehumidification system
    Yang, Yu
    Yan, Junwei
    Zhou, Xuan
    Xiao, Liehui
    Huang, Si-Min
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 131 (131) : 87 - 100
  • [47] Study on desiccant solution control strategies for efficient liquid desiccant air conditioning system control performance
    Reddy, Siva Kumar Y.
    Balasubramanian, Karthik
    Chandramohan, V. P.
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2019, 25 (03) : 322 - 335
  • [48] Experimental and theoretical analysis of liquid desiccant dehumidification process based on an advanced hybrid air-conditioning system
    Chen, Yao
    Zhang, Xiaosong
    Yin, Yonggao
    APPLIED THERMAL ENGINEERING, 2016, 98 : 387 - 399
  • [49] Application of biomass-based wood shaving packing in a liquid desiccant dehumidification system - a source of sustainable energy
    Salins, Sampath Suranjan
    Reddy, S. V. Kota
    Kumar, Shiva
    Nair, Prasanth Sreekumaran
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2024, 43 (01)
  • [50] Investigation on a two-stage solar liquid-desiccant (LiBr) dehumidification system assisted by CaCl2 solution
    Xiong, Z. Q.
    Dai, Y. J.
    Wang, R. Z.
    APPLIED THERMAL ENGINEERING, 2009, 29 (5-6) : 1209 - 1215