Investigation of an ejector-cascaded vapor compression-absorption refrigeration cycle powered by linear fresnel and organic rankine cycle

被引:9
|
作者
Askari, Ighball Baniasad [1 ]
Ghazizade-Ahsaee, Hossein [2 ]
Kasaeian, Alibakhsh [3 ]
机构
[1] Univ Zabol, Fac Engn, Dept Mech Engn, Zabol, Iran
[2] Tech & Vocat Univ TVU, Dept Mech Engn, Tehran, Iran
[3] Univ Tehran, Fac New Sci & Technol, Dept Renewable Energies & Environm, Tehran, Iran
关键词
Cascade refrigeration; Food storage; Solar field; Thermal energy storage; Thermoelectric; Ejector; THERMOELECTRIC GENERATOR; COOLING SYSTEM; PERFORMANCE-CHARACTERISTICS; THERMOECONOMIC ANALYSIS; FINANCIAL EVALUATION; BIOENERGY INDUSTRY; ECONOMIC-ANALYSIS; EXERGY ANALYSIS; SOLAR; ENERGY;
D O I
10.1007/s10668-022-02442-z
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The low-temperature cooling through the cascade compression-absorption refrigeration system with the solar thermal source is a promising technology to be used in food storage applications. This paper studies an integrated organic rankine cycle (ORC, toluene)/ejector-cascade compression (R1234yf)-absorption (LiBr-H2O) refrigeration system/thermo-electric generator (TEG) powered by the linear Fresnel solar collectors. The power generation of the ORC and TEGs was assumed to supply the electricity consumption of the system. A thermo-economic analysis was performed to determine the influence of different parameters on the system performance, heat transfer areas, solar field, and thermal energy storage (TES) system optimum sizes, and the levelized cost of the cooling energy (COC). The calculations were conducted for three locations to specify the influence of solar radiation level on the system sizes and COC. Based on the results, the energy and exergy efficiencies (eta(I) and eta(II)) vary from 38 to 50% and from 3.6 to 4.6%, respectively. Although the capital investment and complexity are the practical limitations, the cascade cycle coefficient of performance and the system overall efficiency improvement were obtained as 27.02% and 51.19%% over the cycle without ejector and TEG reported in the previous research studies. Also, for three locations with highest, medium, and lowest solar radiation levels, the minimum COC (and annual solar share) was obtained as 0.049-0.062 $/kWh (36-74%), 0.068-0.079 $/kWh (32-55%), and 0.145-0.158 $/kWh (18-27%), respectively, for different TES capacities and capital costs. Moreover, the TEG modules are capable of supplying nearly 27% of the total power consumption of the system. For two regions located in Iran and United Arab Emirates, the COC of the fuel-based system becomes equal to that of the solar-based system if the conventional fuel prices in United Arab Emirates and Iran are increased by 202% and 316%, respectively.
引用
收藏
页码:9439 / 9484
页数:46
相关论文
共 50 条
  • [41] The performance assessment of a combined organic Rankine-vapor compression refrigeration cycle aided hydrogen liquefaction
    Kaska, Onder
    Yilmaz, Ceyhun
    Bor, Onur
    Tokgoz, Nehir
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2018, 43 (44) : 20192 - 20202
  • [42] Comprehensive analysis of a novel power and cooling cogeneration system based on organic Rankine cycle and ejector refrigeration cycle
    Yu, Wei
    Wang, Huitao
    Ge, Zhong
    ENERGY CONVERSION AND MANAGEMENT, 2021, 232
  • [43] THE VAPOUR COMPRESSION-ABSORPTION TWO STAGE REFRIGERATION CYCLE AND ITS COMPARISON WITH ALTERNATIVE CYCLES
    Cimsit, Canan
    Ozturk, Ilhan Tekin
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2014, 34 (01) : 19 - 26
  • [44] Performance analysis of a novel organic Rankine cycle with a vapor-liquid ejector
    Chen, Jianyong
    Huang, Yisheng
    Niu, Zhiting
    Chen, Ying
    Luo, Xianglong
    ENERGY CONVERSION AND MANAGEMENT, 2018, 157 : 382 - 395
  • [45] Thermal analysis of a novel configuration of double effect absorption system cascaded with ejector and injection enhanced compression refrigeration cycle
    Siddique, Sefat Mahmud
    Uzzaman, M. Muhtasim
    Ehsan, M. Monjurul
    Khan, Yasin
    ENERGY CONVERSION AND MANAGEMENT, 2025, 326
  • [46] Performance assessment of a solar based novel combined cycle using vapor compression-absorption refrigeration system for trigeneration application
    Khan, Yunis
    Singh, Pawan Kumar
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2025,
  • [47] Ejector and Vapor Injection Enhanced Novel Compression-Absorption Cascade Refrigeration Systems: A Thermodynamic Parametric and Refrigerant Analysis
    Khan, Yasin
    Faruque, Md Walid
    Nabil, Mahdi Hafiz
    Ehsan, M. Monjurul
    ENERGY CONVERSION AND MANAGEMENT, 2023, 289
  • [48] Performance of a combined organic Rankine cycle and vapor compression cycle for heat activated cooling
    Wang, Hailei
    Peterson, Richard
    Harada, Kevin
    Miller, Erik
    Ingram-Goble, Robbie
    Fisher, Luke
    Yih, James
    Ward, Chris
    ENERGY, 2011, 36 (01) : 447 - 458
  • [49] Assessment of single rotor expander-compressor device in combined organic Rankine cycle (ORC) and vapor compression refrigeration cycle (VCR)
    Alshammari, Saif
    Kadam, Sambhaji T.
    Yu, Zhibin
    ENERGY, 2023, 282
  • [50] Thermodynamic and Thermo-economic Analysis of Integrated Organic Rankine Cycle for Waste Heat Recovery from Vapor Compression Refrigeration Cycle
    Asim, Muhammad
    Leung, Michael K. H.
    Shan, Zhiqiang
    Li, Yingying
    Leung, Dennis Y. C.
    Ni, Meng
    LEVERAGING ENERGY TECHNOLOGIES AND POLICY OPTIONS FOR LOW CARBON CITIES, 2017, 143 : 192 - 198