Spatialization of Chinese R-410A emissions from the room air-conditioning sector

被引:0
|
作者
Wu, Pengcheng [1 ,2 ]
Zhang, Li [2 ,3 ]
Yao, Bo [4 ,5 ]
Cai, Bofeng [2 ]
Zhu, Yifang [3 ]
Liu, Hui [6 ]
Wang, Pengling [7 ]
Liu, Lisha [8 ]
Dou, Yanwei [9 ]
Yan, Han [10 ]
Liu, Yijun [11 ]
Xie, Zixuan [12 ]
Pang, Lingyun [2 ]
Cao, Libin [2 ]
Ren, Yimeng [13 ]
Bo, Xin [14 ]
机构
[1] Sun Yat Sen Univ, Sch Publ Hlth, Guangzhou 510080, Guangdong, Peoples R China
[2] Chinese Acad Environm Planning, Ctr Carbon Neutral, Beijing 100012, Peoples R China
[3] Univ Calif Los Angeles, Inst Environm & Sustainabil, Dept Environm Sci & Engn, Los Angeles, CA 90095 USA
[4] Fudan Univ, Dept Atmospher & Ocean Sci, Songhu Rd 2005, Shanghai 200438, Peoples R China
[5] Fudan Univ, Inst Atmospher Sci, Songhu Rd 2005, Shanghai 200438, Peoples R China
[6] Wuhan Univ, Sch Resource & Environm Sci, Wuhan 430072, Peoples R China
[7] Natl Climate Ctr, Beijing 100081, Peoples R China
[8] Univ New South Wales, Water Res Ctr, Sydney, NSW 2052, Australia
[9] China Household Elect Appliances Assoc, Beijing 100010, Peoples R China
[10] Taikang Asset Management Co LTD, Beijing 100033, Peoples R China
[11] Shanghai Jiao Tong Univ, Sch Environm Sci & Engn, Shanghai 200240, Peoples R China
[12] Washington Univ, Dept Energy Environm & Chem Engn, St Louis, MO 63130 USA
[13] Renmin Univ China, Sch Stat, Beijing 100872, Peoples R China
[14] Beijing Univ Chem Technol, Dept Environm Sci & Engn, Beijing 100029, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
High-resolution; R-410A emissions; Hydrofluorocarbons; Room air-conditioning; Spatialization; Proxy factors; HYDROFLUOROCARBON EMISSIONS; HFC EMISSIONS; NIGHTTIME; INVENTORIES; HFC-410A; IMAGERY;
D O I
10.1007/s10668-022-02264-z
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Hydrofluorocarbons (HFCs) are strong greenhouse gases and regulated by the Montreal Protocol as substitutes of ozone depletion substances. Currently, Chinese HFC emissions keep increasing, and the inventory is only on a national or city level. A high-resolution gridded HFC emission inventory is needed to develop HFC reduction policy and phase-down schedule. We developed a method by integrating point sources with longitude and latitude information and area sources using the proxy factor to explore the distribution of R-410A [a mixture of HFC-32 (CH2F2) and HFC-125 (C2HF5)] emissions from the room air-conditioning sector on a 10 x 10 km(2) grid scale. Variety of regression models (including the principal component analysis, multiple linear regressions, stepwise regressions, and linear regression), analysis scale (national level and provincial level), and data dimensions (the proxy factor and unit-area value) were tested. The gross domestic product was found as the optimal proxy factor and used to spatialize R-410A emissions at a high-resolution scale. Compared to the national-level analysis, model evaluation parameters were largely improved for the provincial-level regression analysis, including root-mean-square error (from 20.96 to 11.35), normalized mean bias (from 0.16 to - 0.01), normalized mean error (from 0.45 to 0.20), mean absolute error (from 11.27 to 4.97), correlation coefficient (from 0.91 to 0.97), and relative error (from 39% to 76%), suggesting a better performance for the provincial-level analysis. This study provides a cost-effective method to establish fine-resolution HFC inventory. Meanwhile, high-resolution emissions grid data could be further applied to implement site-specific management of low-carbon development.
引用
收藏
页码:5263 / 5281
页数:19
相关论文
共 50 条
  • [1] Spatialization of Chinese R-410A emissions from the room air-conditioning sector
    Pengcheng Wu
    Li Zhang
    Bo Yao
    Bofeng Cai
    Yifang Zhu
    Hui Liu
    Pengling Wang
    Lisha Liu
    Yanwei Dou
    Han Yan
    Yijun Liu
    Zixuan Xie
    Lingyun Pang
    Libin Cao
    Yimeng Ren
    Xin Bo
    Environment, Development and Sustainability, 2023, 25 : 5263 - 5281
  • [2] Dynamic characteristics of a R-410A split air-conditioning system
    Kim, MH
    Bullard, CW
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (07): : 652 - 659
  • [3] Transient Characteristics of Split Air-Conditioning Systems Using R-22 and R-410A as Refrigerants
    Kapadia, R. G.
    Jain, Sanjeev
    Agarwal, R. S.
    HVAC&R RESEARCH, 2009, 15 (03): : 617 - 649
  • [4] A case study of thermal analysis of a solar assisted absorption air-conditioning system using R-410A for domestic applications
    Rahman, Areeba
    Abas, Naeem
    Dilshad, Saad
    Saleem, Muhammad Shoaib
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 26
  • [5] Performance of R-410A Alternative Refrigerants in a Reciprocating Compressor Designed for Air Conditioning Applications
    Shrestha, Som S.
    Lenz, James R.
    Vineyard, Edward
    Mumpower, Kevin
    2016 ASHRAE ANNUAL CONFERENCE PAPERS, 2016,
  • [6] Historical and projected emissions of HCFC-22 and HFC-410A from China's room air conditioning sector
    Wang, Ziyuan
    Fang, Xuekun
    Li, Li
    Bie, Pengju
    Li, Zhifang
    Hu, Jianxin
    Zhang, Boya
    Zhang, Jianbo
    ATMOSPHERIC ENVIRONMENT, 2016, 132 : 30 - 35
  • [7] COMPUTER ROOM AIR-CONDITIONING
    GOLDBERG, N
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1973, 15 (10): : 60 - 67
  • [8] Performance Study of Double Pipe Internal Heat Exchanger in R-410a Air Conditioning System
    Djuanda
    INTERNATIONAL CONFERENCE ON THERMAL SCIENCE AND TECHNOLOGY (ICTST) 2017, 2018, 1984
  • [9] AIR-CONDITIONING IN COMPUTER ROOM
    WILSON, T
    DATA PROCESSING, 1969, 11 (02): : 167 - &
  • [10] Historical and projected HFC-410A emission from room air conditioning sector in China
    Liu, Lisha
    Dou, Yanwei
    Yao, Bo
    Bie, Pengju
    Wang, Lei
    Peng, Min
    Hu, Jianxin
    ATMOSPHERIC ENVIRONMENT, 2019, 212 : 194 - 200