Spatialization of Chinese R-410A emissions from the room air-conditioning sector

被引:0
|
作者
Wu, Pengcheng [1 ,2 ]
Zhang, Li [2 ,3 ]
Yao, Bo [4 ,5 ]
Cai, Bofeng [2 ]
Zhu, Yifang [3 ]
Liu, Hui [6 ]
Wang, Pengling [7 ]
Liu, Lisha [8 ]
Dou, Yanwei [9 ]
Yan, Han [10 ]
Liu, Yijun [11 ]
Xie, Zixuan [12 ]
Pang, Lingyun [2 ]
Cao, Libin [2 ]
Ren, Yimeng [13 ]
Bo, Xin [14 ]
机构
[1] Sun Yat Sen Univ, Sch Publ Hlth, Guangzhou 510080, Guangdong, Peoples R China
[2] Chinese Acad Environm Planning, Ctr Carbon Neutral, Beijing 100012, Peoples R China
[3] Univ Calif Los Angeles, Inst Environm & Sustainabil, Dept Environm Sci & Engn, Los Angeles, CA 90095 USA
[4] Fudan Univ, Dept Atmospher & Ocean Sci, Songhu Rd 2005, Shanghai 200438, Peoples R China
[5] Fudan Univ, Inst Atmospher Sci, Songhu Rd 2005, Shanghai 200438, Peoples R China
[6] Wuhan Univ, Sch Resource & Environm Sci, Wuhan 430072, Peoples R China
[7] Natl Climate Ctr, Beijing 100081, Peoples R China
[8] Univ New South Wales, Water Res Ctr, Sydney, NSW 2052, Australia
[9] China Household Elect Appliances Assoc, Beijing 100010, Peoples R China
[10] Taikang Asset Management Co LTD, Beijing 100033, Peoples R China
[11] Shanghai Jiao Tong Univ, Sch Environm Sci & Engn, Shanghai 200240, Peoples R China
[12] Washington Univ, Dept Energy Environm & Chem Engn, St Louis, MO 63130 USA
[13] Renmin Univ China, Sch Stat, Beijing 100872, Peoples R China
[14] Beijing Univ Chem Technol, Dept Environm Sci & Engn, Beijing 100029, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
High-resolution; R-410A emissions; Hydrofluorocarbons; Room air-conditioning; Spatialization; Proxy factors; HYDROFLUOROCARBON EMISSIONS; HFC EMISSIONS; NIGHTTIME; INVENTORIES; HFC-410A; IMAGERY;
D O I
10.1007/s10668-022-02264-z
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Hydrofluorocarbons (HFCs) are strong greenhouse gases and regulated by the Montreal Protocol as substitutes of ozone depletion substances. Currently, Chinese HFC emissions keep increasing, and the inventory is only on a national or city level. A high-resolution gridded HFC emission inventory is needed to develop HFC reduction policy and phase-down schedule. We developed a method by integrating point sources with longitude and latitude information and area sources using the proxy factor to explore the distribution of R-410A [a mixture of HFC-32 (CH2F2) and HFC-125 (C2HF5)] emissions from the room air-conditioning sector on a 10 x 10 km(2) grid scale. Variety of regression models (including the principal component analysis, multiple linear regressions, stepwise regressions, and linear regression), analysis scale (national level and provincial level), and data dimensions (the proxy factor and unit-area value) were tested. The gross domestic product was found as the optimal proxy factor and used to spatialize R-410A emissions at a high-resolution scale. Compared to the national-level analysis, model evaluation parameters were largely improved for the provincial-level regression analysis, including root-mean-square error (from 20.96 to 11.35), normalized mean bias (from 0.16 to - 0.01), normalized mean error (from 0.45 to 0.20), mean absolute error (from 11.27 to 4.97), correlation coefficient (from 0.91 to 0.97), and relative error (from 39% to 76%), suggesting a better performance for the provincial-level analysis. This study provides a cost-effective method to establish fine-resolution HFC inventory. Meanwhile, high-resolution emissions grid data could be further applied to implement site-specific management of low-carbon development.
引用
收藏
页码:5263 / 5281
页数:19
相关论文
共 50 条
  • [31] Vacuum swing adsorption for R-32 recovery from R-410A refrigerant blend
    Ribeiro, Rui P. P. L.
    Sosa, Julio E.
    Araujo, Joao M. M.
    Pereiro, Ana B.
    Mota, Jose P. B.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 150 : 253 - 264
  • [32] Room airflow distributions and ventilation characteristics by personal air-conditioning system
    Han, HT
    Choi, SH
    Jang, KJ
    Chung, KS
    Park, YC
    Yee, JJ
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 1113 - 1120
  • [33] Simulation of oxygen enrichment characteristics and effect in hypoxia air-conditioning room
    Wang H.-Y.
    Liu Y.-S.
    Zhang C.-Z.
    Chen F.-X.
    Ma X.-J.
    Li C.-W.
    Gongcheng Kexue Xuebao/Chinese Journal of Engineering, 2019, 41 (08): : 1061 - 1073
  • [34] LIMITATION OF NOISE FROM AIR-CONDITIONING SYSTEMS
    LUSARDI, G
    ERGONOMICS, 1969, 12 (05) : 816 - &
  • [35] Regenerated noise from air-conditioning ducts
    Corkill, A.
    1978, 45 (10):
  • [36] Vacuum swing adsorption for R-32 recovery from R-410A refrigerant blend
    Ribeiro, Rui P. P. L.
    Sosa, Julio E.
    Araujo, Joao M. M.
    Pereiro, Ana B.
    Mota, Jose P. B.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 150 : 253 - 264
  • [37] ISOLATION OF LEPTOSPIRES FROM AN AIR-CONDITIONING PLANT
    RIS, DR
    HAMEL, KL
    NEW ZEALAND MEDICAL JOURNAL, 1979, 90 (643) : 212 - 212
  • [38] HEAT RECOVERY AIR-CONDITIONING FROM WELTEMP
    不详
    REFRIGERATION AND AIR CONDITIONING, 1973, 76 (898): : 28 - 28
  • [39] Modeling and experimental study on the performance of an inverter air conditioner using R-410A with evaporatively cooled condenser
    Sarntichartsak, Pongsakorn
    Thepa, Sirichai
    APPLIED THERMAL ENGINEERING, 2013, 51 (1-2) : 597 - 610
  • [40] Two-phase pressure drop of air-water and R-410A in small horizontal tubes
    Chen, IY
    Yang, KS
    Chang, YJ
    Wang, CC
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2001, 27 (07) : 1293 - 1299