Spatialization of Chinese R-410A emissions from the room air-conditioning sector

被引:0
|
作者
Wu, Pengcheng [1 ,2 ]
Zhang, Li [2 ,3 ]
Yao, Bo [4 ,5 ]
Cai, Bofeng [2 ]
Zhu, Yifang [3 ]
Liu, Hui [6 ]
Wang, Pengling [7 ]
Liu, Lisha [8 ]
Dou, Yanwei [9 ]
Yan, Han [10 ]
Liu, Yijun [11 ]
Xie, Zixuan [12 ]
Pang, Lingyun [2 ]
Cao, Libin [2 ]
Ren, Yimeng [13 ]
Bo, Xin [14 ]
机构
[1] Sun Yat Sen Univ, Sch Publ Hlth, Guangzhou 510080, Guangdong, Peoples R China
[2] Chinese Acad Environm Planning, Ctr Carbon Neutral, Beijing 100012, Peoples R China
[3] Univ Calif Los Angeles, Inst Environm & Sustainabil, Dept Environm Sci & Engn, Los Angeles, CA 90095 USA
[4] Fudan Univ, Dept Atmospher & Ocean Sci, Songhu Rd 2005, Shanghai 200438, Peoples R China
[5] Fudan Univ, Inst Atmospher Sci, Songhu Rd 2005, Shanghai 200438, Peoples R China
[6] Wuhan Univ, Sch Resource & Environm Sci, Wuhan 430072, Peoples R China
[7] Natl Climate Ctr, Beijing 100081, Peoples R China
[8] Univ New South Wales, Water Res Ctr, Sydney, NSW 2052, Australia
[9] China Household Elect Appliances Assoc, Beijing 100010, Peoples R China
[10] Taikang Asset Management Co LTD, Beijing 100033, Peoples R China
[11] Shanghai Jiao Tong Univ, Sch Environm Sci & Engn, Shanghai 200240, Peoples R China
[12] Washington Univ, Dept Energy Environm & Chem Engn, St Louis, MO 63130 USA
[13] Renmin Univ China, Sch Stat, Beijing 100872, Peoples R China
[14] Beijing Univ Chem Technol, Dept Environm Sci & Engn, Beijing 100029, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
High-resolution; R-410A emissions; Hydrofluorocarbons; Room air-conditioning; Spatialization; Proxy factors; HYDROFLUOROCARBON EMISSIONS; HFC EMISSIONS; NIGHTTIME; INVENTORIES; HFC-410A; IMAGERY;
D O I
10.1007/s10668-022-02264-z
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Hydrofluorocarbons (HFCs) are strong greenhouse gases and regulated by the Montreal Protocol as substitutes of ozone depletion substances. Currently, Chinese HFC emissions keep increasing, and the inventory is only on a national or city level. A high-resolution gridded HFC emission inventory is needed to develop HFC reduction policy and phase-down schedule. We developed a method by integrating point sources with longitude and latitude information and area sources using the proxy factor to explore the distribution of R-410A [a mixture of HFC-32 (CH2F2) and HFC-125 (C2HF5)] emissions from the room air-conditioning sector on a 10 x 10 km(2) grid scale. Variety of regression models (including the principal component analysis, multiple linear regressions, stepwise regressions, and linear regression), analysis scale (national level and provincial level), and data dimensions (the proxy factor and unit-area value) were tested. The gross domestic product was found as the optimal proxy factor and used to spatialize R-410A emissions at a high-resolution scale. Compared to the national-level analysis, model evaluation parameters were largely improved for the provincial-level regression analysis, including root-mean-square error (from 20.96 to 11.35), normalized mean bias (from 0.16 to - 0.01), normalized mean error (from 0.45 to 0.20), mean absolute error (from 11.27 to 4.97), correlation coefficient (from 0.91 to 0.97), and relative error (from 39% to 76%), suggesting a better performance for the provincial-level analysis. This study provides a cost-effective method to establish fine-resolution HFC inventory. Meanwhile, high-resolution emissions grid data could be further applied to implement site-specific management of low-carbon development.
引用
收藏
页码:5263 / 5281
页数:19
相关论文
共 50 条
  • [41] Evaluation of low-GWP and mildly flammable mixtures as new alternatives for R410A in air-conditioning and heat pump system
    Yu, Binbin
    Ouyang, Hongsheng
    Shi, Junye
    Liu, Wuchan
    Chen, Jiangping
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 121 : 95 - 104
  • [42] Impact of cool storage air-conditioning in commercial sector on power operation in Thailand
    Asian Inst of Technology, Bangkok, Thailand
    Energy Sources, 4 ([d]379-387):
  • [43] Study on technical and economical solutions for improving air-conditioning efficiency in building sector
    Ilie, Anica
    Dumitrescu, Rodica
    Girip, Alina
    Cublesan, Valentin
    SUSTAINABLE SOLUTIONS FOR ENERGY AND ENVIRONMENT, EENVIRO 2016, 2017, 112 : 537 - 544
  • [44] A research on change law of concentration of PM10 in an Air-conditioning Room
    Fan, Yuesheng
    Si, Pengfei
    Li, Angui
    Gong, Rui
    Li, Bowen
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [45] CENTRAL VS ROOM AIR-CONDITIONING FOR REDUCING EXPOSURE TO AIRBORNE FUNGUS SPORES
    PAN, PM
    BURGE, HA
    SU, HJ
    SPENGLER, JD
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1992, 89 (01) : 258 - 258
  • [46] Analysis with field synergy principle of air-conditioning room on four ventilation patterns
    Zheng, Wenheng
    Liu, Jiaping
    Zhang, Qing
    Wang, Yi
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1249 - 1254
  • [47] MACS FOR TELECOMMUNICATIONS EQUIPMENT ROOM - MULTI-UNIT AIR-CONDITIONING SYSTEM
    MATSUURA, F
    SUENAGA, T
    JAPAN TELECOMMUNICATIONS REVIEW, 1985, 27 (03): : 191 - 198
  • [48] STUDY OF R32 REFRIGERANT FOR RESIDENTIAL AIR-CONDITIONING APPLICATIONS
    Tu, X.
    Liang, X.
    Zhuang, R.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 812 - 819
  • [49] REEVALUATION OF AIR-CONDITIONING FROM THE POINT OF VIEW OF OTORHINOLARYNGOLOGY
    KINKADE, JM
    AMA ARCHIVES OF OTOLARYNGOLOGY, 1954, 60 (01): : 15 - 23
  • [50] The performance of the refrigerants R-134a, R-290, R404a, R-407c and R-410A in air conditioners and refrigerators
    Meyer, JP
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2001, 47 (08): : 366 - 373