Virtual pretreatment patient-specific quality assurance of volumetric modulated arc therapy using deep learning

被引:3
|
作者
Yoganathan, S. A. [1 ]
Ahmed, Sharib [1 ]
Paloor, Satheesh [1 ]
Torfeh, Tarraf [1 ]
Aouadi, Souha [1 ]
Al-Hammadi, Noora [1 ]
Hammoud, Rabih [1 ]
机构
[1] Hamad Med Corp, Natl Ctr Canc Care & Res NCCCR, Dept Radiat Oncol, POB 3050, Doha, Qatar
关键词
automatic; deep learning; gamma evaluation; QA; VMAT; ERROR-DETECTION; IMRT QA; RADIOMIC ANALYSIS; CLASSIFICATION; PREDICTION;
D O I
10.1002/mp.16567
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundAutomatic patient-specific quality assurance (PSQA) is recently explored using artificial intelligence approaches, and several studies reported the development of machine learning models for predicting the gamma pass rate (GPR) index only. PurposeTo develop a novel deep learning approach using a generative adversarial network (GAN) to predict the synthetic measured fluence. Methods and materialsA novel training method called "dual training," which involves the training of the encoder and decoder separately, was proposed and evaluated for cycle GAN (cycle-GAN) and conditional GAN (c-GAN). A total of 164 VMAT treatment plans, including 344 arcs (training data: 262, validation data: 30, and testing data: 52) from various treatment sites, were selected for prediction model development. For each patient, portal-dose-image-prediction fluence from TPS was used as input, and measured fluence from EPID was used as output/response for model training. Predicted GPR was derived by comparing the TPS fluence with the synthetic measured fluence generated by the DL models using gamma evaluation of criteria 2%/2 mm. The performance of dual training was compared against the traditional single-training approach. In addition, we also developed a separate classification model specifically designed to detect automatically three types of errors (rotational, translational, and MU-scale) in the synthetic EPID-measured fluence. ResultsOverall, the dual training improved the prediction accuracy of both cycle-GAN and c-GAN. Predicted GPR results of single training were within 3% for 71.2% and 78.8% of test cases for cycle-GAN and c-GAN, respectively. Moreover, similar results for dual training were 82.7% and 88.5% for cycle-GAN and c-GAN, respectively. The error detection model showed high classification accuracy (>98%) for detecting errors related to rotational and translational errors. However, it struggled to differentiate the fluences with "MU scale error" from "error-free" fluences. ConclusionWe developed a method to automatically generate the synthetic measured fluence and identify errors within them. The proposed dual training improved the PSQA prediction accuracy of both the GAN models, with c-GAN demonstrating superior performance over the cycle-GAN. Our results indicate that the c-GAN with dual training approach combined with error detection model, can accurately generate the synthetic measured fluence for VMAT PSQA and identify the errors. This approach has the potential to pave the way for virtual patient-specific QA of VMAT treatments.
引用
收藏
页码:7891 / 7903
页数:13
相关论文
共 50 条
  • [31] Correlation between patient-specific quality assurance in volumetric modulated arc therapy and 2D dose image features
    Yixiao Guo
    Jinyan Hu
    Yang Li
    Juntao Ran
    Hongyi Cai
    Scientific Reports, 13
  • [32] Correlation between patient-specific quality assurance in volumetric modulated arc therapy and 2D dose image features
    Guo, Yixiao
    Hu, Jinyan
    Li, Yang
    Ran, Juntao
    Cai, Hongyi
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [33] Patient-Specific Quality Assurance Using Monte Carlo Dose Calculation and Elekta Log Files for Prostate Volumetric-Modulated Arc Therapy
    Katsuta, Yoshiyuki
    Kadoya, Noriyuki
    Fujita, Yukio
    Shimizu, Eiji
    Matsunaga, Kenichi
    Sawada, Kinya
    Matsushita, Haruo
    Majima, Kazuhiro
    Jingu, Keiichi
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2017, 16 (06) : 1220 - 1225
  • [34] Electronic Portal Imaging Device in Pre-Treatment Patient-Specific Quality Assurance of volumetric-modulated arc therapy delivery
    Lau, M. L.
    Abdullah, R.
    Jayamani, J.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 22
  • [35] Machine Log File and Calibration Errors-based Patient-specific Quality Assurance (QA) for Volumetric Modulated Arc Therapy (VMAT)
    Ma, Yangguang
    Mou, Xuanqin
    Beeraka, Narasimha M.
    Guo, Yuexin
    Liu, Junqi
    Dai, Jianrong
    Fan, Ruitai
    CURRENT PHARMACEUTICAL DESIGN, 2023, 29 (34) : 2738 - 2751
  • [36] Evaluating IMRT and Volumetric Arc Therapy Patient-Specific Quality Assurance by Using Octavius 4D System
    Lee, H.
    Jen, Y.
    MEDICAL PHYSICS, 2014, 41 (06) : 258 - 258
  • [37] Correlation analysis between 2D and 3D patient-specific quality assurance for volumetric modulated arc therapy
    Sharma, S.
    Sharma, D.
    Subramani, V.
    Gopishankar, N.
    Bhaskar, S.
    Pathy, S.
    Kumar, P.
    Thulkar, S.
    Chander, S.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2023, 21 (04): : 685 - 691
  • [38] Treatment plan complexity quantification for predicting gamma passing rates in patient-specific quality assurance for stereotactic volumetric modulated arc therapy
    Xue, Xudong
    Luan, Shunyao
    Ding, Yi
    Li, Xiangbin
    Li, Dan
    Wang, Jingya
    Ma, Chi
    Jiang, Man
    Wei, Wei
    Wang, Xiao
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (09):
  • [39] Quality assurance of volumetric modulated arc therapy using Elekta Synergy
    Haga, Akihiro
    Nakagawa, Keiichi
    Shiraishi, Kenshiro
    Itoh, Saori
    Terahara, Atsuro
    Yamashita, Hideomi
    Ohtomo, Kuni
    Saegusa, Shigeki
    Imae, Toshikazu
    Yoda, Kiyoshi
    Pellegrini, Roberto
    ACTA ONCOLOGICA, 2009, 48 (08) : 1193 - 1197
  • [40] Establishing an optimized patient-specific verification program for volumetric modulated arc therapy
    Serna, Alfredo
    Mata, Fernando
    Puchades, Vicente