Virtual pretreatment patient-specific quality assurance of volumetric modulated arc therapy using deep learning

被引:3
|
作者
Yoganathan, S. A. [1 ]
Ahmed, Sharib [1 ]
Paloor, Satheesh [1 ]
Torfeh, Tarraf [1 ]
Aouadi, Souha [1 ]
Al-Hammadi, Noora [1 ]
Hammoud, Rabih [1 ]
机构
[1] Hamad Med Corp, Natl Ctr Canc Care & Res NCCCR, Dept Radiat Oncol, POB 3050, Doha, Qatar
关键词
automatic; deep learning; gamma evaluation; QA; VMAT; ERROR-DETECTION; IMRT QA; RADIOMIC ANALYSIS; CLASSIFICATION; PREDICTION;
D O I
10.1002/mp.16567
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundAutomatic patient-specific quality assurance (PSQA) is recently explored using artificial intelligence approaches, and several studies reported the development of machine learning models for predicting the gamma pass rate (GPR) index only. PurposeTo develop a novel deep learning approach using a generative adversarial network (GAN) to predict the synthetic measured fluence. Methods and materialsA novel training method called "dual training," which involves the training of the encoder and decoder separately, was proposed and evaluated for cycle GAN (cycle-GAN) and conditional GAN (c-GAN). A total of 164 VMAT treatment plans, including 344 arcs (training data: 262, validation data: 30, and testing data: 52) from various treatment sites, were selected for prediction model development. For each patient, portal-dose-image-prediction fluence from TPS was used as input, and measured fluence from EPID was used as output/response for model training. Predicted GPR was derived by comparing the TPS fluence with the synthetic measured fluence generated by the DL models using gamma evaluation of criteria 2%/2 mm. The performance of dual training was compared against the traditional single-training approach. In addition, we also developed a separate classification model specifically designed to detect automatically three types of errors (rotational, translational, and MU-scale) in the synthetic EPID-measured fluence. ResultsOverall, the dual training improved the prediction accuracy of both cycle-GAN and c-GAN. Predicted GPR results of single training were within 3% for 71.2% and 78.8% of test cases for cycle-GAN and c-GAN, respectively. Moreover, similar results for dual training were 82.7% and 88.5% for cycle-GAN and c-GAN, respectively. The error detection model showed high classification accuracy (>98%) for detecting errors related to rotational and translational errors. However, it struggled to differentiate the fluences with "MU scale error" from "error-free" fluences. ConclusionWe developed a method to automatically generate the synthetic measured fluence and identify errors within them. The proposed dual training improved the PSQA prediction accuracy of both the GAN models, with c-GAN demonstrating superior performance over the cycle-GAN. Our results indicate that the c-GAN with dual training approach combined with error detection model, can accurately generate the synthetic measured fluence for VMAT PSQA and identify the errors. This approach has the potential to pave the way for virtual patient-specific QA of VMAT treatments.
引用
收藏
页码:7891 / 7903
页数:13
相关论文
共 50 条
  • [21] Simplification of head and neck volumetric modulated arc therapy patient-specific quality assurance, using a Delta4 PT
    Sasaki, Motoharu
    Sugimoto, Wataru
    Ikushima, Hitoshi
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (05) : 793 - 800
  • [22] Development of a deep learning-based error detection system without error dose maps in the patient-specific quality assurance of volumetric modulated arc therapy
    Kimura, Yuto
    Kadoya, Noriyuki
    Oku, Yohei
    Jingu, Keiichi
    JOURNAL OF RADIATION RESEARCH, 2023, 64 (04) : 728 - 737
  • [23] Efficient dose-volume histogram-based pretreatment patient-specific quality assurance methodology with combined deep learning and machine learning models for volumetric modulated arc radiotherapy
    Gong, Changfei
    Zhu, Kecheng
    Lin, Chengyin
    Han, Ce
    Lu, Zhongjie
    Chen, Yuanhua
    Yu, Changhui
    Hou, Liqiao
    Zhou, Yongqiang
    Yi, Jinling
    Ai, Yao
    Xiang, Xiaojun
    Xie, Congying
    Jin, Xiance
    MEDICAL PHYSICS, 2022, 49 (12) : 7779 - 7790
  • [24] Verification of patient specific quality assurance system for volumetric modulated arc therapy (VMAT)
    Amoabeng, Kwame Anokye
    Marthinsen, Anne Beate Langeland
    Hasford, Francis
    Tagoe, Samuel Nii Adu
    Anaafi, Evelyn
    HEALTH AND TECHNOLOGY, 2022, 12 (04) : 779 - 786
  • [25] Verification of patient specific quality assurance system for volumetric modulated arc therapy (VMAT)
    Kwame Anokye Amoabeng
    Anne Beate Langeland Marthinsen
    Francis Hasford
    Samuel Nii Adu Tagoe
    Evelyn Anaafi
    Health and Technology, 2022, 12 : 779 - 786
  • [26] Effect of dose grid resolution on the results of patient-specific quality assurance for intensity-modulated radiation therapy and volumetric modulated arc therapy
    Chun, M.
    Kim, J., I
    Oh, G. H.
    Wu, H. G.
    Park, J. M.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (03): : 521 - 530
  • [27] Error detection using a convolutional neural network with dose difference maps in patient-specific quality assurance for volumetric modulated arc therapy
    Kimura, Yuto
    Kadoya, Noriyuki
    Tomori, Seiji
    Oku, Yohei
    Jingu, Keiichi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 73 : 57 - 64
  • [28] Improvement Using Planomics Features on Prediction and Classification of Patient-Specific Quality Assurance Using Head and Neck Volumetric Modulated Arc Therapy Plan
    Li, Bing
    Chen, Junying
    Guo, Wei
    Mao, Ronghu
    Zheng, Xiaoli
    Cheng, Xiuyan
    Cui, Tiantian
    Lou, Zhaoyang
    Wang, Ting
    Li, Dingjie
    Tao, Hongyan
    Lei, Hongchang
    Ge, Hong
    FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [29] Cloud-Based Monte Carlo Patient-Specific Quality Assurance (QA) Method for Volumetric Modulated Arc Therapy (VMAT)
    Chen, X.
    Xing, L.
    Azcona, J.
    Luxton, G.
    Bush, K.
    MEDICAL PHYSICS, 2014, 41 (06) : 237 - 238
  • [30] Patient specific quality assurance of volumetric modulated arc therapy of synchronous bilateral breast cancer
    Zamo, Francis C. Djoumessi
    Njeh, Christopher F.
    Colliaux, Anthony
    Blot-Lafond, Valerie
    Moyo, M. Ndontchueng
    MEDICAL DOSIMETRY, 2024, 49 (03) : 177 - 184