Calibration-free blood pressure estimation based on a convolutional neural network

被引:0
|
作者
Cho, Jinwoo [1 ]
Shin, Hangsik [2 ,5 ]
Choi, Ahyoung [3 ,4 ]
机构
[1] Bud on Co Ltd, Seoul, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Digital Med, Seoul, South Korea
[3] Gachon Univ, Dept AI Software, Seongnam, South Korea
[4] Gachon Univ, Dept AI Software, Seongnam 13120, South Korea
[5] Univ Ulsan, Asan Med Ctr, Dept Digital Med, Coll Med, Seoul 05505, South Korea
基金
新加坡国家研究基金会;
关键词
blood pressure estimation; convolutional neural network; electrocardiogram; photoplethysmogram; wearable environment; PULSE TRANSIT-TIME; WAVE; VARIABILITY; DISPERSION; DURATION;
D O I
10.1111/psyp.14480
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
In this study, we conducted research on a deep learning-based blood pressure (BP) estimation model suitable for wearable environments. To measure BP while wearing a wearable watch, it needs to be considered that computing power for signal processing is limited and the input signals are subject to noise interference. Therefore, we employed a convolutional neural network (CNN) as the BP estimation model and utilized time-series electrocardiogram (ECG) and photoplethysmogram (PPG) signals, which are quantifiable in a wearable context. We generated periodic input signals and used differential and thresholding methods to decrease noise in the preprocessing step. We then applied a max-pooling technique with filter sizes of 2 x 1 and 5 x 1 within a 3-layer convolutional neural network to estimate BP. Our method was trained, validated, and tested using 2.4 million data samples from 49 patients in the intensive care unit. These samples, totaling 3.1 GB were obtained from the publicly accessible MIMIC database. As a result of a test with 480,000 data samples, the average root mean square error in BP estimation was 3.41, 5.80, and 2.78 mm Hg in the prediction of pulse pressure, systolic BP (SBP), and diastolic BP (DBP), respectively. The cumulative error percentage less than 5 mm Hg was 68% and 93% for SBP and DBP, respectively. In addition, the cumulative error percentage less than 15 mm Hg was 98% and 99% for SBP and DBP. Subsequently, we evaluated the impact of changes in input signal length (1 cycle vs. 30 s) and the introduction of noise on BP estimation results. The experimental results revealed that the length of the input signal did not significantly affect the performance of CNN-based analysis. When estimating BP using noise-added ECG signals, the mean absolute error (MAE) for SBP and DBP was 9.72 and 6.67 mm Hg, respectively. Meanwhile, when using noise-added PPG signals, the MAE for SBP and DBP was 26.85 and 14.00 mm Hg, respectively. Therefore, this study confirmed that using ECG signals rather than PPG signals is advantageous for noise reduction in a wearable environment. Besides, short sampling frames without calibration can be effective as input signals. Furthermore, it demonstrated that using a model suitable for information extraction rather than a specialized deep learning model for sequential data can yield satisfactory results in BP estimation.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Calibration-Free BCI Based Control
    Grizou, Jonathan
    Iturrate, Inaki
    Montesano, Luis
    Oudeyer, Pierre-Yves
    Lopes, Manuel
    PROCEEDINGS OF THE TWENTY-EIGHTH AAAI CONFERENCE ON ARTIFICIAL INTELLIGENCE, 2014, : 1213 - 1220
  • [22] Cuff-Less High-Accuracy Calibration-Free Blood Pressure Estimation Using Pulse Transit Time
    Kachuee, Mohamad
    Kiani, Mohammad Mahdi
    Mohammadzade, Hoda
    Shabany, Mahdi
    2015 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2015, : 1006 - 1009
  • [23] PPG-Based Electronic Sensing System for Cuff-Less Calibration-Free Blood Pressure Estimation Using Machine Learning Algorithms
    Botrugno, Chiara
    Dell'Olio, Francesco
    2024 IEEE SENSORS APPLICATIONS SYMPOSIUM, SAS 2024, 2024,
  • [24] BLOOD PRESSURE ESTIMATION FROM PPG SIGNALS USING CONVOLUTIONAL NEURAL NETWORKS AND SIAMESE NETWORK
    Schlesinger, Oded
    Vigderhouse, Nitai
    Eytan, Danny
    Moshe, Yair
    2020 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2020, : 1135 - 1139
  • [25] Cuffless blood pressure estimation using chaotic features of photoplethysmograms and parallel convolutional neural network
    Khodabakhshi, Mohammad Bagher
    Eslamyeh, Naeem
    Sadredini, Seyede Zohreh
    Ghamari, Mohammad
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2022, 226
  • [26] Full-DOF calibration-free robotic hand-eye coordination based on fuzzy neural network
    Su, JB
    Pan, QL
    Luo, ZW
    ADVANCES IN NEURAL NETWORKS - ISNN 2004, PT 2, 2004, 3174 : 7 - 12
  • [27] Calibration-free IMU-based Kinematic State Estimation for Robotic Manipulators
    Fennel, Michael
    Driller, Lukas
    Zea, Antonio
    Hanebeck, Uwe D.
    2022 IEEE INTERNATIONAL CONFERENCE ON MULTISENSOR FUSION AND INTEGRATION FOR INTELLIGENT SYSTEMS (MFI), 2022,
  • [28] Approximate calibration-free trajectory reconstruction in a wireless network
    Almudevar, Anthony
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2008, 56 (07) : 3081 - 3088
  • [29] A Convolutional Neural Network Based Calibration Scheme for Pipelined ADC
    Liu, Hang
    Lu, Zhifei
    Ye, Xiaolei
    Xiao, Yao
    Peng, Yutao
    Zhang, Wei
    Tang, Yong
    Tang, He
    Peng, Xizhu
    2023 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, ISCAS, 2023,
  • [30] Cuff-less Blood Pressure Measurement Based on Deep Convolutional Neural Network
    Liu, ZengDing
    Miao, Fen
    Wang, Ruxin
    Liu, Jikui
    Wen, Bo
    Li, Ye
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 3775 - 3778