Calibration-free blood pressure estimation based on a convolutional neural network

被引:0
|
作者
Cho, Jinwoo [1 ]
Shin, Hangsik [2 ,5 ]
Choi, Ahyoung [3 ,4 ]
机构
[1] Bud on Co Ltd, Seoul, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Digital Med, Seoul, South Korea
[3] Gachon Univ, Dept AI Software, Seongnam, South Korea
[4] Gachon Univ, Dept AI Software, Seongnam 13120, South Korea
[5] Univ Ulsan, Asan Med Ctr, Dept Digital Med, Coll Med, Seoul 05505, South Korea
基金
新加坡国家研究基金会;
关键词
blood pressure estimation; convolutional neural network; electrocardiogram; photoplethysmogram; wearable environment; PULSE TRANSIT-TIME; WAVE; VARIABILITY; DISPERSION; DURATION;
D O I
10.1111/psyp.14480
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
In this study, we conducted research on a deep learning-based blood pressure (BP) estimation model suitable for wearable environments. To measure BP while wearing a wearable watch, it needs to be considered that computing power for signal processing is limited and the input signals are subject to noise interference. Therefore, we employed a convolutional neural network (CNN) as the BP estimation model and utilized time-series electrocardiogram (ECG) and photoplethysmogram (PPG) signals, which are quantifiable in a wearable context. We generated periodic input signals and used differential and thresholding methods to decrease noise in the preprocessing step. We then applied a max-pooling technique with filter sizes of 2 x 1 and 5 x 1 within a 3-layer convolutional neural network to estimate BP. Our method was trained, validated, and tested using 2.4 million data samples from 49 patients in the intensive care unit. These samples, totaling 3.1 GB were obtained from the publicly accessible MIMIC database. As a result of a test with 480,000 data samples, the average root mean square error in BP estimation was 3.41, 5.80, and 2.78 mm Hg in the prediction of pulse pressure, systolic BP (SBP), and diastolic BP (DBP), respectively. The cumulative error percentage less than 5 mm Hg was 68% and 93% for SBP and DBP, respectively. In addition, the cumulative error percentage less than 15 mm Hg was 98% and 99% for SBP and DBP. Subsequently, we evaluated the impact of changes in input signal length (1 cycle vs. 30 s) and the introduction of noise on BP estimation results. The experimental results revealed that the length of the input signal did not significantly affect the performance of CNN-based analysis. When estimating BP using noise-added ECG signals, the mean absolute error (MAE) for SBP and DBP was 9.72 and 6.67 mm Hg, respectively. Meanwhile, when using noise-added PPG signals, the MAE for SBP and DBP was 26.85 and 14.00 mm Hg, respectively. Therefore, this study confirmed that using ECG signals rather than PPG signals is advantageous for noise reduction in a wearable environment. Besides, short sampling frames without calibration can be effective as input signals. Furthermore, it demonstrated that using a model suitable for information extraction rather than a specialized deep learning model for sequential data can yield satisfactory results in BP estimation.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Calibration-Free Footstep Frequency Estimation Using Structural Vibration
    Mirshekari, Mostafa
    Zhang, Pei
    Noh, Hae Young
    DYNAMICS OF CIVIL STRUCTURES, VOL 2, 2017, : 287 - 289
  • [42] Feature-Based Neural Network Approach for Oscillometric Blood Pressure Estimation
    Forouzanfar, Mohamad
    Dajani, Hilmi R.
    Groza, Voicu Z.
    Bolic, Miodrag
    Rajan, Sreeraman
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (08) : 2786 - 2796
  • [43] Cuffless blood pressure estimation based on composite neural network and graphics information
    Qiu, Ye
    Liu, Dongdong
    Yang, Guoyu
    Qi, Dezhen
    Lu, Yuer
    He, Qingzu
    Qian, Xiangyu
    Li, Xiang
    Cao, Yuping
    Shuai, Jianwei
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 70 (70)
  • [44] Calibration-free indicator of very small differences in gas pressure
    Robbelen, E
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1937, 81 : 1285 - 1285
  • [45] Fully automated, real-time, calibration-free, continuous noninvasive estimation of intracranial pressure in children
    Fanelli, Andrea
    Vonberg, Frederick W.
    LaRovere, Kerri L.
    Walsh, Brian K.
    Smith, Edward R.
    Robinson, Shenandoah
    Tasker, Robert C.
    Heldt, Thomas
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2019, 24 (05) : 509 - 519
  • [46] A Convolutional Neural Network-Based Relative Radiometric Calibration Method
    Li, Xutao
    Ye, Zhizi
    Ye, Yunming
    Hu, Xiuqing
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2022, 60
  • [47] Classification of Blood Pressure Levels Based on Photoplethysmogram and Electrocardiogram Signals with a Concatenated Convolutional Neural Network
    Fuadah, Yunendah Nur
    Lim, Ki Moo
    DIAGNOSTICS, 2022, 12 (11)
  • [48] Central Aortic Blood Pressure Waveform Estimation with a Temporal Convolutional Network
    Liu, Wenyan
    Du, Shuo
    Pang, Na
    Zhang, Liangyu
    Sun, Guozhe
    Xiao, Hanguang
    Zhao, Qi
    Xu, Lisheng
    Yao, Yudong
    Alastruey, Jordi
    Avolio, Alberto
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2023, 27 (07) : 3622 - 3632
  • [49] Convolutional neural network-based pose mapping estimation as an alternative to traditional hand-eye calibration
    Zhou, Kuai
    Huang, Xiang
    Li, Shuanggao
    Li, Gen
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (06):
  • [50] Remote Estimation of Continuous Blood Pressure by a Convolutional Neural Network Trained on Spatial Patterns of Facial Pulse Waves
    Iuchi, Kaito
    Miyazaki, Ryogo
    Cardoso, George C.
    Ogawa-Ochiai, Keiko
    Tsumura, Norimichi
    2022 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS, CVPRW 2022, 2022, : 2138 - 2144