共 50 条
Utilization of a novel PVC- optical sensor for high sensitive and selective determination of zinc ion in real samples
被引:8
|作者:
Alshehri, Reem F.
[1
]
El-Feky, Hesham H.
[2
]
Askar, Abdelrazek M.
[2
]
Amin, Alaa S.
[2
]
Aish, Mai
[3
]
机构:
[1] Taibah Univ, Coll Sci & Arts, Chem Dept, Medina, Saudi Arabia
[2] Benha Univ, Fac Sci, Chem Dept, Banha, Egypt
[3] Port Said Univ, Fac Sci, Chem Dept, Port Said, Egypt
关键词:
Optical Sensors;
Zinc determination;
Polymer inclusion membrane;
Arsenazo dyes;
Colorimetry;
Environmental analysis;
FLOW-INJECTION ANALYSIS;
SPECTROPHOTOMETRIC DETERMINATION;
BULK OPTODE;
FLUORESCENCE ENHANCEMENT;
CO-LIMITATION;
METAL-IONS;
TEST STRIP;
MEMBRANE;
ALUMINUM;
NEUROBIOLOGY;
D O I:
10.1016/j.saa.2023.123424
中图分类号:
O433 [光谱学];
学科分类号:
0703 ;
070302 ;
摘要:
A novel and highly specific bulk membrane optode was developed for the ultra-sensitive detection of zinc(II) in biological, pharmaceutical, and water samples. The polymer inclusion membrane (PIM) utilized in this study consists of 50% polyvinyl chloride (PVC) as a base polymer, 9.00% DOP (dioctylphthalate) as the plasticizer, and 40.0% D2EHPA (di(2-ethlyhexyl)phosphoric acid) as the carrier. To facilitate the spectrophotometric determination of zinc(II), a colorimetric reagent, namely 4-(2-arsonophenylazo) salicylic acid (APASA) {1.00%, m/v}, was employed. When Zn(II) was extracted into the PIM, it led to the creation of the zinc-D2EHPA complex. This complex then underwent a reaction with APASA, resulting in the formation of a red Zn -APASA complex with a maximum absorption wavelength (lambda max) of 558 nm. To optimize the response of the optode, a central composite design was employed, considering variables such as the amount of additive and reagent, response time, and pH. When operated under the specific optimal conditions, the sensor demonstrated a limit of quantification (LOQ) of 0.74 ng/mL (equivalent to 1.17 x 10-8 M) and a limit of detection (LOD) of 0.22 ng/mL (equivalent to 3.44 x 10- 9 M). The optode membrane demonstrated excellent reproducibility, stability, and a relatively long lifespan, making it suitable for precise and accurate monitoring of Zn(II) ion content. Regeneration of the optode was achieved effectively using 0.25 nitric acid solution, and its response exhibited reversibility and reproducibility, showed a relative standard deviation of less than 1.33%. Moreover, the PIM-APASA optode exhibited a high level of effectiveness in accurately determining the presence of Zn(II) ions in real environmental samples.
引用
收藏
页数:11