摘要
A novel and highly specific bulk membrane optode was developed for the ultra-sensitive detection of zinc(II) in biological, pharmaceutical, and water samples. The polymer inclusion membrane (PIM) utilized in this study consists of 50% polyvinyl chloride (PVC) as a base polymer, 9.00% DOP (dioctylphthalate) as the plasticizer, and 40.0% D2EHPA (di(2-ethlyhexyl)phosphoric acid) as the carrier. To facilitate the spectrophotometric determination of zinc(II), a colorimetric reagent, namely 4-(2-arsonophenylazo) salicylic acid (APASA) {1.00%, m/v}, was employed. When Zn(II) was extracted into the PIM, it led to the creation of the zinc-D2EHPA complex. This complex then underwent a reaction with APASA, resulting in the formation of a red Zn -APASA complex with a maximum absorption wavelength (lambda max) of 558 nm. To optimize the response of the optode, a central composite design was employed, considering variables such as the amount of additive and reagent, response time, and pH. When operated under the specific optimal conditions, the sensor demonstrated a limit of quantification (LOQ) of 0.74 ng/mL (equivalent to 1.17 x 10-8 M) and a limit of detection (LOD) of 0.22 ng/mL (equivalent to 3.44 x 10- 9 M). The optode membrane demonstrated excellent reproducibility, stability, and a relatively long lifespan, making it suitable for precise and accurate monitoring of Zn(II) ion content. Regeneration of the optode was achieved effectively using 0.25 nitric acid solution, and its response exhibited reversibility and reproducibility, showed a relative standard deviation of less than 1.33%. Moreover, the PIM-APASA optode exhibited a high level of effectiveness in accurately determining the presence of Zn(II) ions in real environmental samples.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Determination of Neodymium(III) in Aqueous and Soil Samples with Use of a High-Sensitive and Selective Membrane Sensor
    Pourjavid, Mohammad Reza
    Yousefi, Seyed Reza
    Hosseini, Majid Haji
    Rezaee, Mohammad
    Razavi, Taherehsadat
    Sehat, Ali Akbari
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (06): : 5147 - 5162
  • [22] High sensitive determination of zinc with novel water-soluble small molecular fluorescent sensor
    Weng, Ying
    Chen, Zilin
    Wang, Fang
    Xue, Lin
    Jiang, Hua
    ANALYTICA CHIMICA ACTA, 2009, 647 (02) : 215 - 218
  • [23] Application of nickel zinc ferrite/graphene nanocomposite as a modifier for fabrication of a sensitive electrochemical sensor for determination of omeprazole in real samples
    Aflthami, Abbas
    Bahiraei, Atousa
    Madrakian, Tayyebeh
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2017, 495 : 1 - 8
  • [24] A novel PVC-membrane optical sensor for high sensitive and selective determination of Cu2 + ion based on synthesized (E)-N′-(Pyridin-2-ylmethylene)isonicotinohydrazide (vol 199, pg 483, 2014)
    Ghaedi, M.
    Shahamiri, A.
    Hajati, S.
    Mirtamizdoust, B.
    JOURNAL OF MOLECULAR LIQUIDS, 2015, 204 : 268 - 268
  • [25] Design of a novel optical sensor for determination of trace amounts of copper by UV/vis spectrophotometry in the real samples
    Pourbasheer, Eslam
    Morsali, Somayeh
    Banaei, Alireza
    Aghabalazadeh, Sajjad
    Ganjali, Mohammad Reza
    Norouzi, Parviz
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2015, 26 : 370 - 374
  • [26] Development of a selective and highly sensitive optical chemical sensor for determination of sulfaguanidine based on a novel mixed isopolymolybdates
    Najlaoui, D.
    Echabaane, M.
    Ben Khelifa, A.
    Rouis, A.
    OPTIK, 2021, 231
  • [27] A novel ion selective PVC membrane electrode for determination of propranolol in pharmaceutical formulation
    Aboul-Enein, HY
    Sun, XX
    ANALUSIS, 2000, 28 (09) : 855 - 858
  • [28] Sensitive and selective ion chromatographic method for the determination of trace beryllium in water samples
    Bashir, W
    Paull, B
    JOURNAL OF CHROMATOGRAPHY A, 2001, 910 (02) : 301 - 309
  • [29] Sol-gel derived highly selective optical sensor for sensitive determination of the mercury(II) ion in solution
    Yari, Abdollah
    Abdoli, Hamzeh Adelpour
    JOURNAL OF HAZARDOUS MATERIALS, 2010, 178 (1-3) : 713 - 717
  • [30] Development of a highly sensitive and selective optical chemical sensor for batch and flow-through determination of mercury ion
    Amini, M. K.
    Khezri, B.
    Firooz, A. R.
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 131 (02) : 470 - 478