A novel ion selective PVC membrane electrode for determination of propranolol in pharmaceutical formulation

被引:32
|
作者
Aboul-Enein, HY
Sun, XX
机构
[1] King Faisal Specialist Hosp & Res Ctr, Dept Biol & Med Res, Pharmaceut Anal Lab, Riyadh 11211, Saudi Arabia
[2] Jiangsu Inst Petrochem Technol, Dept Chem Technol, Changzhou 213016, Peoples R China
关键词
propranolol; ion-selective electrode; potentiometry; analysis of drugs; pharmaceutical analysis; chemical sensors;
D O I
10.1051/analusis:2000156
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel ion selective PVC membrane electrode for determination of propranolol is developed. Silicotungstic acid is used as the counter ion and diisononyl phthalate (DNP) used as the plastizer. The electrode exhibits excellent potential response properties, showing a Nernstian response in the concentration of 3.0 x 10(-6) similar to 2.6 x 10(-2) M with the slope of 54.7 mV per decade, shorter conditioning time (similar to 3 h), fast response time (40 s), a lower limit of detection (1.0 x 10(-7) M). The electrode is successfully used for the analysis of propranolol in pharmaceutical formulation with the recoveries of 99.2 similar to 102.6 %, by using a direct potentiometric method and which does not require tedious sample preparation.