A novel ion selective PVC membrane electrode for determination of propranolol in pharmaceutical formulation

被引:32
|
作者
Aboul-Enein, HY
Sun, XX
机构
[1] King Faisal Specialist Hosp & Res Ctr, Dept Biol & Med Res, Pharmaceut Anal Lab, Riyadh 11211, Saudi Arabia
[2] Jiangsu Inst Petrochem Technol, Dept Chem Technol, Changzhou 213016, Peoples R China
关键词
propranolol; ion-selective electrode; potentiometry; analysis of drugs; pharmaceutical analysis; chemical sensors;
D O I
10.1051/analusis:2000156
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel ion selective PVC membrane electrode for determination of propranolol is developed. Silicotungstic acid is used as the counter ion and diisononyl phthalate (DNP) used as the plastizer. The electrode exhibits excellent potential response properties, showing a Nernstian response in the concentration of 3.0 x 10(-6) similar to 2.6 x 10(-2) M with the slope of 54.7 mV per decade, shorter conditioning time (similar to 3 h), fast response time (40 s), a lower limit of detection (1.0 x 10(-7) M). The electrode is successfully used for the analysis of propranolol in pharmaceutical formulation with the recoveries of 99.2 similar to 102.6 %, by using a direct potentiometric method and which does not require tedious sample preparation.
引用
收藏
页码:855 / 858
页数:4
相关论文
共 50 条
  • [41] PVC membrane ion selective electrode for the determination of pentachlorophenol in water, wood and soil using tetrazolium pentachlorophenolate
    Abbas, MN
    Mostafa, GAE
    Homoda, AMA
    TALANTA, 2001, 55 (03) : 647 - 656
  • [42] CHLORATE ION-SELECTIVE ELECTRODE OF PVC MATRIX MEMBRANE TYPE
    FUKAMACHI, K
    ISHIBASHI, N
    BUNSEKI KAGAKU, 1977, 26 (01) : 69 - 72
  • [43] EXPERIMENTS WITH PVC MATRIX MEMBRANE CALCIUM ION-SELECTIVE ELECTRODE
    BIRCH, BJ
    CRAGGS, A
    MOODY, GJ
    THOMAS, JDR
    JOURNAL OF CHEMICAL EDUCATION, 1978, 55 (11) : 740 - 741
  • [44] Propranolol hydrochloride-selective membrane electrode and their application to pharmaceutical preparations and biological fluids
    El-Tohamy, Maha
    El-Maamly, Magda
    Shalaby, Abdalla
    BULLETIN OF PHARMACEUTICAL SCIENCES, 2006, 29 : 488 - 500
  • [45] PVC membrane ion selective electrodes for determination of cationic surfactants
    Devi, Sunaina
    Chattopadhyaya, M. C.
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2011, 88 (11) : 1745 - 1749
  • [47] Determination of diclofenac in pharmaceutical preparations using a novel PVC membrane sensor
    Hassan, SSM
    Mahmoud, WH
    Elmosallamy, MAF
    Almarzooqi, MH
    PHARMAZIE, 2003, 58 (01): : 29 - 31
  • [48] Novel PVC membrane uranyl ion-selective sensor
    Saleh, MB
    Soliman, EM
    Gaber, AAA
    Ahmed, SA
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01) : 199 - 205
  • [49] Venlafaxine Determination in Pharmaceutical Formulation and Serum by Ion-Selective Electrodes
    Mansour, Marwa F.
    Abd El-Moety, Mona M.
    El Kady, Ehab F.
    El Guindi, N. M.
    Van Schepdael, Ann
    Aly, S. M. El-Moghazy
    CURRENT PHARMACEUTICAL DESIGN, 2018, 24 (22) : 2625 - 2630
  • [50] LIQUID MEMBRANE-ELECTRODE FOR SELECTIVE DETERMINATION OF SALICYLATE IN PHARMACEUTICAL PREPARATIONS
    HASSAN, SSM
    HAMADA, MA
    ANALYST, 1988, 113 (11) : 1709 - 1713