Surgical Navigation System for Pedicle Screw Placement Based on Mixed Reality

被引:1
|
作者
Hwang, Seokbin [1 ]
Lee, Suk-joong [2 ,3 ]
Kim, Sungmin [4 ]
机构
[1] Univ Ulsan, Dept Elect Elect & Comp Engn, 93 Daehak Ro, Ulsan 44610, South Korea
[2] Gyeongsang Natl Univ, Coll Med, Dept Orthopaed Surg, 11 Samjeongja Ro, Chang Won, Gyeongsangnam D, South Korea
[3] Gyeongsang Natl Univ, Changwon Hosp, 11 Samjeongja Ro, Chang Won, Gyeongsangnam D, South Korea
[4] Univ Ulsan, Dept Biomed Engn, 93 Daehak Ro, Ulsan 44610, South Korea
基金
新加坡国家研究基金会;
关键词
HoloLens; mixed reality; pedicle screw placement; surgical navigation; ACCURACY; METAANALYSIS;
D O I
10.1007/s12555-023-0083-6
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Inaccurate screw insertion has been a major concern in pedicle screw placement in spinal surgery because of the potential for postoperative complications. Efforts to improve screw insertion have led to the development of novel surgical navigation systems. However, current surgical navigation systems have several problems in that the attention of surgeons is frequently interrupted during surgery, and complications occur in their depth perception because of the limitations of 2D monitors. This study proposes a surgical navigation system to address these issues using mixed reality (MR)-based smart glasses. We developed a navigation system that provides 3D visualization of the surgical tool with respect to the patient's anatomy. It utilizes preoperative surgical planning data to provide visual feedback and guidance. An orthopedic surgeon performed pedicle screw placement with the navigation system in two different environments, using Microsoft HoloLens (HoloLens) and a 2D monitor. The results were evaluated according to procedural time, translational error, angular error, and clinical accuracy. The mean procedural time was 111.3 +/- 52.7 s with the HoloLens and 192.1 +/- 104.0 s with the 2D monitor. The mean translational error was 2.14 +/- 1.13 mm at the entry and 3.14 +/- 0.90 mm at the target with HoloLens. With the 2D monitor, the mean translational error was 2.10 +/- 0.97 mm and 3.41 +/- 2.16 mm at the entry and the target, respectively. The mean angular error was 6.44 +/- 1.94 deg with HoloLens and 7.14 +/- 4.20 deg with the 2D monitor. All screws were inserted intrapedicularly in both environments. The navigation system enables free visualization, reflects the human eye's perspective, and retains the advantages of MR-based smart glasses. A navigation system compatible with minimally invasive surgery should be developed in the future.
引用
收藏
页码:3983 / 3993
页数:11
相关论文
共 50 条
  • [21] Design and validation of a surgical navigation system for brachytherapy based on mixed reality
    Zhou, Zeyang
    Yang, Zhiyong
    Jiang, Shan
    Zhang, Fujun
    Yan, Huzheng
    MEDICAL PHYSICS, 2019, 46 (08) : 3709 - 3718
  • [22] Surgical Navigation System for Hypertensive Intracerebral Hemorrhage Based on Mixed Reality
    Zeyang Zhou
    Zhiyong Yang
    Shan Jiang
    Jie Zhuo
    Tao Zhu
    Shixing Ma
    Journal of Digital Imaging, 2022, 35 (6) : 1530 - 1543
  • [23] Surgical Navigation System for Hypertensive Intracerebral Hemorrhage Based on Mixed Reality
    Zhou, Zeyang
    Yang, Zhiyong
    Jiang, Shan
    Zhuo, Jie
    Zhu, Tao
    Ma, Shixing
    CANCER MANAGEMENT AND RESEARCH, 2022, 14 : 1530 - 1543
  • [24] Augmented reality-based navigation increases precision of pedicle screw insertion
    Dennler, Cyrill
    Jaberg, Laurenz
    Spirig, Jose
    Agten, Christoph
    Gotschi, Tobias
    Furnstahl, Philipp
    Farshad, Mazda
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [25] Augmented reality-based navigation increases precision of pedicle screw insertion
    Cyrill Dennler
    Laurenz Jaberg
    José Spirig
    Christoph Agten
    Tobias Götschi
    Philipp Fürnstahl
    Mazda Farshad
    Journal of Orthopaedic Surgery and Research, 15
  • [26] An Augmented Reality-Based Interaction Scheme for Robotic Pedicle Screw Placement
    Voros, Viktor
    Li, Ruixuan
    Davoodi, Ayoob
    Wybaillie, Gauthier
    Vander Poorten, Emmanuel
    Niu, Kenan
    JOURNAL OF IMAGING, 2022, 8 (10)
  • [27] Pedicle Screw Placement With O-arm and Stealth Navigation
    Patil, Suresh
    Lindley, Emily M.
    Burger, Evalina L.
    Yoshihara, Hiroyuki
    Patel, Vikas V.
    ORTHOPEDICS, 2012, 35 (01) : E61 - E65
  • [28] Intraoperative three-dimensional navigation for pedicle screw placement
    Grützner, PA
    Beutler, T
    Wendl, K
    von Recum, J
    Wentzensen, A
    Nolte, LP
    CHIRURG, 2004, 75 (10): : 967 - 975
  • [29] Meta-analysis of fluoroscopic and navigation-based cervical pedicle screw placement
    Soliman, Mohamed A. R.
    Khan, Asham
    Pollina, John
    Mullin, Jeffrey P.
    JOURNAL OF NEUROSURGERY-SPINE, 2022, 36 (03) : 522 - 523
  • [30] Augmented reality navigated pedicle screw placement - a cadaveric study
    Spirig, Jose
    Roner, Simon
    Liebmann, Florentin
    Furnstahl, Philipp
    Farshad, Mazda
    SWISS MEDICAL WEEKLY, 2019, 149 : 20S - 20S