Intraoperative three-dimensional navigation for pedicle screw placement

被引:32
|
作者
Grützner, PA
Beutler, T
Wendl, K
von Recum, J
Wentzensen, A
Nolte, LP
机构
[1] Heidelberg Univ, Klin Unfall & Wiederherstellungschirurg, Berufsgenossensch Unfallklin Ludwigshafen, D-67071 Ludwigshafen, Germany
[2] Univ Bern, ME Muller Res Ctr Orthopaed Surg, Inst Surg Technol & Biomechan, CH-3012 Bern, Switzerland
来源
CHIRURG | 2004年 / 75卷 / 10期
关键词
computer-assisted surgery; intraoperative imaging; SIREMOBIL Iso-C-3D; C-arm; navigation; pedicle screw;
D O I
10.1007/s00104-004-0944-3
中图分类号
R61 [外科手术学];
学科分类号
摘要
The mobile SIREMOBIL iso-C-3D C-arm (Siemens, Erlangen, Germany) is the first device permitting intraoperative, three-dimensional representation of bone structures. A high-resolution, isotropic 3D data cube in the isocenter with sides of approximately 12 cm is calculated simultaneously. The SIREMOBIL Iso-C-3D is linked to the navigation system. This makes it possible to transfer the generated 3D data directly to the linked navigation system without the need for surgeon-dependent registration. In this prospective clinical trial, we evaluated the accuracy of pedicle screw placement using this device. In 61 patients, a total of 302 pedicle screws were placed. Only in five cases (1.7%) were misplacements of >2 mm shown in postoperative control CT. The average fluoroscopy time was 1.28 +/- 0.56 min, and the average operative duration was 103.26 +/- 23.3 min. There were no postoperative neurological complications in any of the 30 patients. From these data, we conclude that Iso-C-3D navigation is a very accurate method for the placement of pedicle screws.
引用
收藏
页码:967 / 975
页数:13
相关论文
共 50 条
  • [1] Three-Dimensional Patient-Specific Guides for Intraoperative Navigation for Cortical Screw Trajectory Pedicle Fixation
    Kim, Jiwon
    Rajadurai, Jeremy
    Choy, Wen Jie
    Cassar, Lachlan
    Phan, Kevin
    Harris, Leigh
    Fiechter, Meinrad
    Mobbs, Ralph J.
    WORLD NEUROSURGERY, 2019, 122 : 674 - 679
  • [2] Assessing intraoperative pedicle screw placement accuracy using biplanar radiographs compared to three-dimensional imaging
    Gorgy, George
    Avrumova, Fedan
    Paschal, Philip K.
    Paschal, Gregory K.
    Carrino, John A.
    Lebl, Darren R.
    JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)
  • [3] Feasibility of mixed reality-based intraoperative three-dimensional image-guided navigation for atlanto-axial pedicle screw placement
    Wu, Xinghuo
    Liu, Rong
    Xu, Song
    Yang, Cao
    Yang, Shuhua
    Shao, Zengwu
    Li, Suyun
    Ye, Zhewei
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2019, 233 (12) : 1310 - 1317
  • [4] Three-dimensional Fluoroscopy-based Navigation for the Pedicle Screw Placement in Patients with Primary Invasive Spinal Tumors
    Jin, Bo
    Su, Yi-Bing
    Zhao, Ji-Zong
    CHINESE MEDICAL JOURNAL, 2016, 129 (21) : 2552 - 2558
  • [5] Three-dimensional Fluoroscopy-based Navigation for the Pedicle Screw Placement in Patients with Primary Invasive Spinal Tumors
    Bo Jin
    Yi-Bing Su
    Ji-Zong Zhao
    中华医学杂志英文版, 2016, 129 (21) : 2552 - 2558
  • [6] Design and basic research on accuracy of a novel individualized three-dimensional printed navigation template in atlantoaxial pedicle screw placement
    Chen, Xiao-Long
    Xie, Ya-Fen
    Li, Jian-Xin
    Wu, Wu
    Li, Guan-Nan
    Hu, Hui-Jing
    Wang, Xiao-Yun
    Meng, Zhao-Jian
    Wen, Yue-Feng
    Huang, Wen-Hua
    PLOS ONE, 2019, 14 (04):
  • [7] Accuracy of pedicle screw placement by fluoroscopy, a three-dimensional printed model, local electrical conductivity measurement device, and intraoperative computed tomography navigation in scoliosis patients
    Kudo, Hitoshi
    Wada, Kanichiro
    Kumagai, Gentaro
    Tanaka, Sunao
    Asari, Toru
    Ishibashi, Yasuyuki
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2021, 31 (03): : 563 - 569
  • [8] Accuracy of pedicle screw placement by fluoroscopy, a three-dimensional printed model, local electrical conductivity measurement device, and intraoperative computed tomography navigation in scoliosis patients
    Hitoshi Kudo
    Kanichiro Wada
    Gentaro Kumagai
    Sunao Tanaka
    Toru Asari
    Yasuyuki Ishibashi
    European Journal of Orthopaedic Surgery & Traumatology, 2021, 31 : 563 - 569
  • [9] Accuracy of upper thoracic pedicle screw placement using three-dimensional image guidance
    Bledsoe, Jonathan M.
    Fenton, Doug
    Fogelson, Jeremy L.
    Nottmeier, Eric W.
    SPINE JOURNAL, 2009, 9 (10): : 817 - 821
  • [10] Navigation an der Brust- und Lendenwirbelsäule mit dem 3D-BildwandlerIntraoperative three-dimensional navigation for pedicle screw placement
    P. A. Grützner
    T. Beutler
    K. Wendl
    J. von Recum
    A. Wentzensen
    L.-P. Nolte
    Der Chirurg, 2004, 75 : 967 - 975