Intraoperative three-dimensional navigation for pedicle screw placement

被引:32
|
作者
Grützner, PA
Beutler, T
Wendl, K
von Recum, J
Wentzensen, A
Nolte, LP
机构
[1] Heidelberg Univ, Klin Unfall & Wiederherstellungschirurg, Berufsgenossensch Unfallklin Ludwigshafen, D-67071 Ludwigshafen, Germany
[2] Univ Bern, ME Muller Res Ctr Orthopaed Surg, Inst Surg Technol & Biomechan, CH-3012 Bern, Switzerland
来源
CHIRURG | 2004年 / 75卷 / 10期
关键词
computer-assisted surgery; intraoperative imaging; SIREMOBIL Iso-C-3D; C-arm; navigation; pedicle screw;
D O I
10.1007/s00104-004-0944-3
中图分类号
R61 [外科手术学];
学科分类号
摘要
The mobile SIREMOBIL iso-C-3D C-arm (Siemens, Erlangen, Germany) is the first device permitting intraoperative, three-dimensional representation of bone structures. A high-resolution, isotropic 3D data cube in the isocenter with sides of approximately 12 cm is calculated simultaneously. The SIREMOBIL Iso-C-3D is linked to the navigation system. This makes it possible to transfer the generated 3D data directly to the linked navigation system without the need for surgeon-dependent registration. In this prospective clinical trial, we evaluated the accuracy of pedicle screw placement using this device. In 61 patients, a total of 302 pedicle screws were placed. Only in five cases (1.7%) were misplacements of >2 mm shown in postoperative control CT. The average fluoroscopy time was 1.28 +/- 0.56 min, and the average operative duration was 103.26 +/- 23.3 min. There were no postoperative neurological complications in any of the 30 patients. From these data, we conclude that Iso-C-3D navigation is a very accurate method for the placement of pedicle screws.
引用
收藏
页码:967 / 975
页数:13
相关论文
共 50 条
  • [31] Robot-assisted Percutaneous Pedicle Screw Placement Using Three-dimensional Fluoroscopy: A Preliminary Clinical Study
    Tian, Wei
    Fan, Ming-Xing
    Liu, Ya-Jun
    CHINESE MEDICAL JOURNAL, 2017, 130 (13) : 1617 - 1618
  • [32] Robot-assisted Percutaneous Pedicle Screw Placement Using Three-dimensional Fluoroscopy: A Preliminary Clinical Study
    Tian Wei
    Fan Ming-Xing
    Liu Ya-Jun
    中华医学杂志英文版, 2017, 130 (13) : 1617 - 1618
  • [33] Electrical stimulation for intraoperative evaluation of thoracic pedicle screw placement
    Shi, YB
    Binette, M
    Martin, WH
    Pearson, JM
    Hart, RA
    SPINE, 2003, 28 (06) : 595 - 601
  • [34] Computer-Assisted Surgery and Intraoperative Three-Dimensional Imaging for Screw Placement in Different Pelvic Regions
    Grossterlinden, Lars
    Nuechtern, Jakob
    Begemann, Philipp G. C.
    Fuhrhop, Ina
    Petersen, Jan P.
    Ruecker, Andreas
    Rupprecht, Martin
    Lehmann, Wolfgang
    Schumacher, Udo
    Rueger, Johannes M.
    Briem, Daniel
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 71 (04): : 926 - 932
  • [35] Occipital condyle screw placement and occipitocervical instrumentation using three-dimensional image-guided navigation
    Le, Tien V.
    Burkett, Clint
    Ramos, Edwin
    Uribe, Juan S.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2012, 19 (05) : 757 - 760
  • [36] Pedicle Screw Placement With O-arm and Stealth Navigation
    Patil, Suresh
    Lindley, Emily M.
    Burger, Evalina L.
    Yoshihara, Hiroyuki
    Patel, Vikas V.
    ORTHOPEDICS, 2012, 35 (01) : E61 - E65
  • [37] Comparison of three imaging and navigation systems regarding accuracy of pedicle screw placement in a sawbone model
    Nils Beisemann
    Jula Gierse
    Eric Mandelka
    Frank Hassel
    Paul A. Grützner
    Jochen Franke
    Sven Y. Vetter
    Scientific Reports, 12
  • [38] Comparison of three imaging and navigation systems regarding accuracy of pedicle screw placement in a sawbone model
    Beisemann, Nils
    Gierse, Jula
    Mandelka, Eric
    Hassel, Frank
    Gruetzner, Paul A.
    Franke, Jochen
    Vetter, Sven Y.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [39] Routine spinal navigation for thoraco-lumbar pedicle screw insertion using the O-arm three-dimensional imaging system improves placement accuracy
    Ling, Ji Min
    Dinesh, Shree Kumar
    Pang, Boon Chuan
    Chen, Min Wei
    Lim, Heng Lip
    Louange, Danny T.
    Yu, Chun Sing
    Wang, Chee Meng Ernest
    JOURNAL OF CLINICAL NEUROSCIENCE, 2014, 21 (03) : 493 - 498
  • [40] Placement of pedicle screws using three-dimensional fluoroscopy-based navigation in lumbar vertebrae with axial rotation
    Wei Tian
    Zhao Lang
    European Spine Journal, 2010, 19 : 1928 - 1935