Surgical Navigation System for Pedicle Screw Placement Based on Mixed Reality

被引:1
|
作者
Hwang, Seokbin [1 ]
Lee, Suk-joong [2 ,3 ]
Kim, Sungmin [4 ]
机构
[1] Univ Ulsan, Dept Elect Elect & Comp Engn, 93 Daehak Ro, Ulsan 44610, South Korea
[2] Gyeongsang Natl Univ, Coll Med, Dept Orthopaed Surg, 11 Samjeongja Ro, Chang Won, Gyeongsangnam D, South Korea
[3] Gyeongsang Natl Univ, Changwon Hosp, 11 Samjeongja Ro, Chang Won, Gyeongsangnam D, South Korea
[4] Univ Ulsan, Dept Biomed Engn, 93 Daehak Ro, Ulsan 44610, South Korea
基金
新加坡国家研究基金会;
关键词
HoloLens; mixed reality; pedicle screw placement; surgical navigation; ACCURACY; METAANALYSIS;
D O I
10.1007/s12555-023-0083-6
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Inaccurate screw insertion has been a major concern in pedicle screw placement in spinal surgery because of the potential for postoperative complications. Efforts to improve screw insertion have led to the development of novel surgical navigation systems. However, current surgical navigation systems have several problems in that the attention of surgeons is frequently interrupted during surgery, and complications occur in their depth perception because of the limitations of 2D monitors. This study proposes a surgical navigation system to address these issues using mixed reality (MR)-based smart glasses. We developed a navigation system that provides 3D visualization of the surgical tool with respect to the patient's anatomy. It utilizes preoperative surgical planning data to provide visual feedback and guidance. An orthopedic surgeon performed pedicle screw placement with the navigation system in two different environments, using Microsoft HoloLens (HoloLens) and a 2D monitor. The results were evaluated according to procedural time, translational error, angular error, and clinical accuracy. The mean procedural time was 111.3 +/- 52.7 s with the HoloLens and 192.1 +/- 104.0 s with the 2D monitor. The mean translational error was 2.14 +/- 1.13 mm at the entry and 3.14 +/- 0.90 mm at the target with HoloLens. With the 2D monitor, the mean translational error was 2.10 +/- 0.97 mm and 3.41 +/- 2.16 mm at the entry and the target, respectively. The mean angular error was 6.44 +/- 1.94 deg with HoloLens and 7.14 +/- 4.20 deg with the 2D monitor. All screws were inserted intrapedicularly in both environments. The navigation system enables free visualization, reflects the human eye's perspective, and retains the advantages of MR-based smart glasses. A navigation system compatible with minimally invasive surgery should be developed in the future.
引用
收藏
页码:3983 / 3993
页数:11
相关论文
共 50 条
  • [41] Accuracy of pedicle screw placement based on preoperative computed tomography versus intraoperative data set acquisition for spinal navigation system
    Liu, Hao
    Chen, Weikai
    Liu, Tao
    Meng, Bin
    Yang, Huilin
    JOURNAL OF ORTHOPAEDIC SURGERY, 2017, 25 (02):
  • [42] Effectiveness of the Thoracic Pedicle Screw Placement Using the Virtual Surgical Training System: A Cadaver Study
    Hou, Yang
    Lin, Yanping
    Shi, Jiangang
    Chen, Huajiang
    Yuan, Wen
    OPERATIVE NEUROSURGERY, 2018, 15 (06) : 677 - 685
  • [43] Pedicle-screw placement
    Perkins, PG
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (10): : 1515 - 1515
  • [44] Tracked Ultrasound Snapshots in Percutaneous Pedicle Screw Placement Navigation: A Feasibility Study
    Ungi, Tamas
    Moult, Eric
    Schwab, Joseph H.
    Fichtinger, Gabor
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (12) : 4047 - 4055
  • [45] REDUCTION IN PEDICLE SCREW PLACEMENT TIME WITH A GUIDEWIRELESS PEDICLE SCREW SYSTEM FOR MINIMALLY INVASIVE SPINE SURGERY
    Greenleaf, R.
    Grossi, P.
    Erb, M.
    El-Sayegh, R.
    Pracyk, J. B.
    Marcini, A.
    VALUE IN HEALTH, 2021, 24 : S126 - S126
  • [46] Pediatric Lumbar Pedicle Screw Placement Using Navigation TemplatesA Cadaveric Study
    Xing Wang
    Jun Shi
    Shojie Zhang
    Zhifeng Zhang
    Xiaohe Li
    Zhijun Li
    Indian Journal of Orthopaedics, 2017, 51 : 468 - 473
  • [47] Pediatric Lumbar Pedicle Screw Placement Using Navigation Templates A Cadaveric Study
    Wang, Xing
    Shi, Jun
    Zhang, Shojie
    Zhang, Zhifeng
    Li, Xiaohe
    Li, Zhijun
    INDIAN JOURNAL OF ORTHOPAEDICS, 2017, 51 (04) : 468 - 473
  • [48] Guideline for Thoracolumbar Pedicle Screw Placement Assisted by Orthopaedic Surgical Robot
    Tian, Wei
    Liu, Ya-jun
    Liu, Bo
    He, Da
    Wu, Jing-ye
    Han, Xiao-guang
    Zhao, Jing-wei
    Fan, Ming-xing
    Cai, Lin
    Cao, Xiang-yang
    Fang, Huan-sheng
    Gao, Chun-zheng
    Hao, Ding-jun
    Hu, Yong-cheng
    Li, Ming
    Li, Chun-xia
    Li, Chun-de
    Li, Kai-nan
    Liao, Yi
    Liu, Hao
    Liu, Bao-ge
    Liu, Jun
    Liu, Shi-dong
    Liu, Xin-yu
    Liu, Ya-Jun
    Ma, Xin-long
    Shen, Cai-liang
    Shen, Hong-xing
    Song, Yue-ming
    Sun, Tian-sheng
    Wang, Yue
    Xia, Ya-yi
    Xu, Jian-zhong
    Yang, Hui-lin
    Yang, Xue-jun
    Yin, Guo-yong
    Zhang, Shu-dong
    Zhang, Wei-guo
    Zhao, Yu
    Zhu, Yue
    ORTHOPAEDIC SURGERY, 2019, 11 (02) : 153 - 159
  • [49] Vertebral templates combined with augmented reality technology for guidance of pedicle screw placement
    Wu, Zhanglei
    Wang, Shuyi
    Chen, Zan
    Zhang, Can
    Shao, Hongran
    Fu, Xiaoni
    Ma, Bangfeng
    Yu, Jiaqi
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2022, 15 (12): : 414 - 422
  • [50] Augmented reality-navigated pedicle screw placement: a cadaveric pilot study
    José Miguel Spirig
    Simon Roner
    Florentin Liebmann
    Philipp Fürnstahl
    Mazda Farshad
    European Spine Journal, 2021, 30 : 3731 - 3737