Systemic observation and measurement of microgap formation in dental implant-abutment connection interface under fatigue

被引:0
|
作者
Mercan, Cigdem [2 ]
Bulutsuz, Asli Gunay [1 ]
Katiboglu, Ahmet Bulent [3 ]
机构
[1] Yildiz Tech Univ, TR-34349 Istanbul, Turkiye
[2] Istanbul Univ, Dent Fac, Istanbul, Turkiye
[3] Atlas Univ, Istanbul, Turkiye
关键词
microgap; fatigue test; experimental design; dental implant-abutment interface; measurement; IN-VITRO EVALUATION; BACTERIAL-COLONIZATION; STRESS-DISTRIBUTION; MICROBIAL LEAKAGE; 2-STAGE IMPLANTS; MARGINAL FIT; DIAMETER; LOAD; INFLAMMATION; MICROMOTION;
D O I
10.1515/mt-2023-0071
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Today, a variety of implant designs with different attachment types are widely used in dental implant systems to eliminate connection problems. However, there are still design issues that can significantly affect the long-term success of dental implants. One of these problems is the formation of a microgap in the abutment-implant interface, which can lead to abutment screw loosening, screw fracture, and abutment fracture under masticatory loading. In this in vitro study, the effects of gingival height, dental implant diameter, and abutment type (solid, digital, and ball) on microgap formation were observed after repetitive fatigue tests using an experimental design. After the tests, the optimal design factors were determined to minimize microgap formation. According to the results of the experimental design, the abutment type was found to be the most influential parameter on microgap formation. An implant diameter of 4.1 mm, the smallest gingival height of 0.5 mm, and a digital attachment combination were identified as the optimal design parameters based on the statistical approach (R-2 = 85.3 %).
引用
收藏
页码:1679 / 1685
页数:7
相关论文
共 50 条
  • [41] Development of a new quantitative gas permeability method for dental implant-abutment connection tightness assessment
    Torres, Jacques-Henri
    Mechali, Michael
    Romieu, Olivier
    Tramini, Paul
    Callas, Sylvie
    Cuisinier, Frederic J. G.
    Levallois, Bernard
    BIOMEDICAL ENGINEERING ONLINE, 2011, 10
  • [42] MICROGAP AND MICROMOTION AT THE IMPLANT ABUTMENT INTERFACE CAUSE MARGINAL BONE LOSS AROUND DENTAL IMPLANT BUT MORE EVIDENCE IS NEEDED
    Alqutaibi, Ahmed Yaseen
    Aboalrejal, Afaf Noman
    JOURNAL OF EVIDENCE-BASED DENTAL PRACTICE, 2018, 18 (02) : 171 - 172
  • [43] Implant-Abutment Contact Surfaces and Microgap Measurements of Different Implant Connections Under 3-Dimensional X-Ray Microtomography
    Scarano, Antonio
    Valbonetti, Luca
    Degidi, Marco
    Pecci, Raffaella
    Piattelli, Adriano
    de Oliveira, P. S.
    Perrotti, Vittoria
    IMPLANT DENTISTRY, 2016, 25 (05) : 656 - 662
  • [44] Bacterial contamination along implant-abutment interface in external and internal-hex dental implants
    de Oliveira, Greison Rabelo
    Olate, Sergio
    Pozzer, Leandro
    Cavalieri-Pereira, Lucas
    Rodrigues-Chessa, Jaime G.
    Albergaria-Barbosa, Jose Ricardo
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2014, 7 (03): : 580 - 585
  • [45] Does prophylactic application of doxycycline at the implant-abutment interface improve clinical outcomes of dental implants?
    Ali, Kamran
    McColl, Ewen
    EVIDENCE-BASED DENTISTRY, 2022, 23 (04) : 158 - 159
  • [46] Microleakage and mechanical behavior of conical vs. internal hexagon implant-abutment connection under a cyclic load fatigue test
    Lorusso, F.
    Lucchina, A. Greco
    Romano, F.
    Falisi, G.
    Di Carmine, M. S.
    Bugea, C.
    Scarano, A.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2023, 27 : 122 - 127
  • [47] Effects of Implant-Abutment Connection Type and Inter-Implant Distance on Inter-Implant Bone Stress and Microgap: Three-Dimensional Finite Element Analysis
    Matsuoka, Takashi
    Nakano, Tamaki
    Yamaguchi, Satoshi
    Ono, Shinji
    Watanabe, Shota
    Sato, Takumi
    Yatani, Hirofumi
    MATERIALS, 2021, 14 (09)
  • [48] Effect of the Coronal Wall Thickness of Dental Implants on the Screw Joint Stability in the Internal Implant-Abutment Connection
    Lee, Ji-Hye
    Huh, Yoon-Hyuk
    Park, Chan-Jin
    Cho, Lee-Ra
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (05) : 1058 - 1065
  • [49] Effect of Implant-Abutment Connection Type on Bone Around Dental Implants in Long-Term Observation: Internal Cone Versus Internal Hex
    Szyszkowski, Adam
    Kozakiewicz, Marcin
    IMPLANT DENTISTRY, 2019, 28 (05) : 430 - 436
  • [50] Biomechanical effects of dental implant diameter, connection type, and bone density on microgap formation and fatigue failure: A finite element analysis
    Lee, Hyeonjong
    Jo, Minhye
    Noh, Gunwoo
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 200