Effect of Implant-Abutment Connection Type on Bone Around Dental Implants in Long-Term Observation: Internal Cone Versus Internal Hex

被引:15
|
作者
Szyszkowski, Adam [1 ]
Kozakiewicz, Marcin [1 ]
机构
[1] Med Univ Lodz, Dept Maxillofacial Surg, Ul Cynarskiego 4-27, PL-92447 Lodz, Poland
关键词
marginal bone loss; dental implants; dental digital radiography; MORSE TAPER IMPLANTS; IN-VITRO EVALUATION; STRESS-DISTRIBUTION; MICROGAP LOCATION; MICROBIAL LEAKAGE; INTERFACE; BACTERIAL; JOINT; MICROLEAKAGE; RESISTANCE;
D O I
10.1097/ID.0000000000000905
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to evaluate the influence of the implant-abutment connection type on the bone level around dental implants in long-term observation and the survival rate for the different types of implant-abutment connections. Materials and Methods: Two groups of implants made of titanium grade 23 alloy and with sandblasted and acid-etched (SLA) surface were included in the study: (a) the internal hex implant-abutment connection group (480 SPI dental implants; Alpha-Bio Tec, Petach Tikwa, Israel, 184 patients) and (b) the internal cone implant-abutment connection group (60 C1 dental implants; MIS Implant Technologies, Shlomi, Israel, 34 patients). Certain inclusion and exclusion criteria were applied. Marginal bone loss (MBL) around the dental implants was measured in intraoral radiographs taken with parallel technique with a film holder and by bite recording index. X-rays were performed at the moment of functional loading, and at 12, 24, 36, and 60 months after loading. The digital analysis was conducted using Dental Studio 2.0 computer software. Results: Average MBL was significantly lower in the conical connection compared with internal hex groupd0.68 +/- 0.59 versus 0.99 +/- 0.89 mm (12 months), 0.78 +/- 0.80 versus 1.12 +/- 1.00 mm (24 months), 0.83 +/- 0.87 versus 1.22 +/- 1.03 mm (36 months), and 0.96 +/- 1.02 versus 1.30 +/- 1.15 mm (60 months after loading). Both groups of implants achieved a 100% survival rate. Conclusion: The internal cone connection reduced bone resorption compared with the internal hex. Both groups of implants had a 100% survival rate.
引用
收藏
页码:430 / 436
页数:7
相关论文
共 40 条
  • [1] Long-term effect of implant-abutment connection type on marginal bone loss and survival of dental implants
    Kim, Young-Min
    Lee, Jong-Bin
    Um, Heung-Sik
    Chang, Beom-Seok
    Lee, Jae-Kwan
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2022, 52 (06): : 496 - 508
  • [2] Bacterial contamination along implant-abutment interface in external and internal-hex dental implants
    de Oliveira, Greison Rabelo
    Olate, Sergio
    Pozzer, Leandro
    Cavalieri-Pereira, Lucas
    Rodrigues-Chessa, Jaime G.
    Albergaria-Barbosa, Jose Ricardo
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2014, 7 (03): : 580 - 585
  • [3] Effect of the Coronal Wall Thickness of Dental Implants on the Screw Joint Stability in the Internal Implant-Abutment Connection
    Lee, Ji-Hye
    Huh, Yoon-Hyuk
    Park, Chan-Jin
    Cho, Lee-Ra
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (05) : 1058 - 1065
  • [4] Fracture Resistance of the Implant-Abutment Connection in Implants with Internal Hex and Internal Conical Connections Under Oblique Compressive Loading: An In Vitro Study
    Coppede, Abilio Ricciardi
    Bersani, Edmilson
    Chiarello de Mattos, Maria da Gloria
    Silveira Rodrigues, Renata Cristina
    de Mattias Sartori, Ivete Aparecida
    Ribeiro, Ricardo Faria
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2009, 22 (03) : 283 - 286
  • [5] A retrospective study of 12,538 internal conical connection implants focused on the long-term integrity of implant-abutment complexes
    Jin, Xiaoting
    Guan, Ye
    Ren, Jie
    Zhao, Yanwei
    Wang, Xiaoxiang
    He, Fuming
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (04) : 377 - 390
  • [6] The Effect of Internal Versus External Abutment Connection Modes on Crestal Bone Changes Around Dental Implants: A Radiographic Analyes
    Koo, Ki-Tae
    Lee, Eun-Jeong
    Kim, Jae-Yoon
    Seol, Yang-Jo
    Han, Jung Suk
    Kim, Tae-Il
    Lee, Yong Moo
    Ku, Young
    Wikesjoe, Ulf M. E.
    Rhyu, In-Chul
    JOURNAL OF PERIODONTOLOGY, 2012, 83 (09) : 1104 - 1109
  • [7] Tactile misfit detection ability at the implant-abutment interface of internal connection dental implants: an in-vitro study
    Molinero-Mourelle, Pedro
    Peter, Lukas
    Gaviria, Ana Sol
    Fonseca, Manrique
    Schimmel, Martin
    Katsoulis, Joannis
    ACTA ODONTOLOGICA SCANDINAVICA, 2023, 81 (08) : 591 - 596
  • [8] Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems
    Jo, Jae-Young
    Yang, Dong-Seok
    Huh, Jung-Bo
    Heo, Jae-Chan
    Yun, Mi-Jung
    Jeong, Chang-Mo
    JOURNAL OF ADVANCED PROSTHODONTICS, 2014, 6 (06): : 491 - 497
  • [9] Analysis of the abutment-implant platform gap in internal hex dental implants.
    Cardozo, Ricardo
    Olate, Sergio
    Navarro, Pablo
    Araya, Javier
    Gonzalez, Omar
    Carrasco, Juan
    Zenteno, Claudia
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (08): : 3336 - 3339
  • [10] The influence of prosthetic crown height and implant-abutment connection design selection on the long-term implant-abutment stability: A laboratory study
    Bagegni, Aimen
    Spies, Benedikt C.
    Kern, Matthias
    Hazard, Derek
    Kohal, Ralf
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 113