Systemic observation and measurement of microgap formation in dental implant-abutment connection interface under fatigue

被引:0
|
作者
Mercan, Cigdem [2 ]
Bulutsuz, Asli Gunay [1 ]
Katiboglu, Ahmet Bulent [3 ]
机构
[1] Yildiz Tech Univ, TR-34349 Istanbul, Turkiye
[2] Istanbul Univ, Dent Fac, Istanbul, Turkiye
[3] Atlas Univ, Istanbul, Turkiye
关键词
microgap; fatigue test; experimental design; dental implant-abutment interface; measurement; IN-VITRO EVALUATION; BACTERIAL-COLONIZATION; STRESS-DISTRIBUTION; MICROBIAL LEAKAGE; 2-STAGE IMPLANTS; MARGINAL FIT; DIAMETER; LOAD; INFLAMMATION; MICROMOTION;
D O I
10.1515/mt-2023-0071
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Today, a variety of implant designs with different attachment types are widely used in dental implant systems to eliminate connection problems. However, there are still design issues that can significantly affect the long-term success of dental implants. One of these problems is the formation of a microgap in the abutment-implant interface, which can lead to abutment screw loosening, screw fracture, and abutment fracture under masticatory loading. In this in vitro study, the effects of gingival height, dental implant diameter, and abutment type (solid, digital, and ball) on microgap formation were observed after repetitive fatigue tests using an experimental design. After the tests, the optimal design factors were determined to minimize microgap formation. According to the results of the experimental design, the abutment type was found to be the most influential parameter on microgap formation. An implant diameter of 4.1 mm, the smallest gingival height of 0.5 mm, and a digital attachment combination were identified as the optimal design parameters based on the statistical approach (R-2 = 85.3 %).
引用
收藏
页码:1679 / 1685
页数:7
相关论文
共 50 条
  • [21] Candida spp colonization of the dental implant-abutment interface: An in vitro study
    Calcaterra, R.
    Di Girolamo, M.
    Mirisola, C.
    Baggi, L.
    MYCOSES, 2012, 55 : 80 - 81
  • [22] Analysis of the Mechanical Behavior and Effect of Cyclic Fatigue on the Implant-Abutment Interface
    German Sandoval, Ramon
    Ortiz Magdaleno, Marine
    Sanchez Robles, Paula
    Zavala Alonso, Norma
    Romo Ramirez, Gabriel Fernando
    ODOVTOS INTERNATIONAL JOURNAL OF DENTAL SCIENCES, 2021, 23 (02) : 104 - 114
  • [23] Implant-abutment interface design affects fatigue and fracture strength of implants
    Steinebrunner, Lars
    Wolfart, Stefan
    Ludwig, Klaus
    Kern, Matthias
    CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (12) : 1276 - 1284
  • [24] Stability of implant-abutment connection in three different systems after fatigue test
    Bajoghli, Farshad
    Sabouhi, Mohmoud
    Pourali, Mohamad
    Davoudi, Amin
    THE JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2022, 22 (04) : 338 - 342
  • [25] Tactile misfit detection ability at the implant-abutment interface of internal connection dental implants: an in-vitro study
    Molinero-Mourelle, Pedro
    Peter, Lukas
    Gaviria, Ana Sol
    Fonseca, Manrique
    Schimmel, Martin
    Katsoulis, Joannis
    ACTA ODONTOLOGICA SCANDINAVICA, 2023, 81 (08) : 591 - 596
  • [26] Implant–abutment connections: influence of the design on the microgap and their fatigue and fracture behavior of dental implants
    F. J. Gil
    M. Herrero-Climent
    P. Lázaro
    J. V. Rios
    Journal of Materials Science: Materials in Medicine, 2014, 25 : 1825 - 1830
  • [27] Impact of implant-abutment connection and positioning of the machined collar/microgap on crestal bone level changes: a systematic review
    Schwarz, Frank
    Hegewald, Andrea
    Becker, Juergen
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (04) : 417 - 425
  • [28] Effects of different torque levels on the implant-abutment interface in a conical internal connection
    Alexandre Gehrke, Sergio
    Shibli, Jamil Awad
    Aramburu Junior, Jaime Sarda
    Mate Sanchez de Val, Jose Eduardo
    Luis Calvo-Girardo, Jose
    Dedavid, Berenice Anina
    BRAZILIAN ORAL RESEARCH, 2016, 30 (01):
  • [29] In Vitro Analysis of the Implant-Abutment Interface Connection and Bacterial Infiltration in Two Extraoral Implant Models
    de Souza, Ricardo Salgado
    Suffredini, Ivana Barbosa
    Cortizo, Daniela Lattuf
    Larsson, Anna
    Nannmark, Ulf
    Dib, Luciano Lauria
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (01) : 63 - 69
  • [30] Influence of Implant-Abutment Contact Surfaces and Prosthetic Screw Tightening on the Stress Concentration, Fatigue Life and Microgap Formation: A Finite Element Analysis
    Tribst, Joao Paulo Mendes
    Dal Piva, Amanda Maria de Oliveira
    da Silva-Concilio, Lais Regiane
    Ausiello, Pietro
    Kalman, Les
    ORAL, 2021, 1 (02): : 88 - 101