Performance of a heat recovery ventilation system for controlling human exposure to airborne particles in a residential building

被引:4
|
作者
Park, Seongjun [1 ]
Lee, Shinhye [2 ]
Yeo, Myoung-Souk [2 ,3 ]
Rim, Donghyun [1 ]
机构
[1] Penn State Univ, Dept Architectural Engn, University Pk, PA 16802 USA
[2] Seoul Natl Univ, Dept Architecture & Architectural Engn, Seoul, South Korea
[3] Seoul Natl Univ, Inst Construct & Environm Engn, Seoul, South Korea
基金
新加坡国家研究基金会; 美国国家科学基金会;
关键词
Indoor air quality; PM2; 5; Exposure control; Indoor emissions; Mass balance model; Bypass factor; PORTABLE AIR CLEANERS; ULTRAFINE PARTICLES; FINE PARTICLES; CONTROL STRATEGIES; SOURCE EMISSION; OUTDOOR; IMPACT; RATES; INFILTRATION; FILTRATION;
D O I
10.1016/j.buildenv.2023.110412
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Heat recovery ventilation (HRV) system is emerging as a sustainable technology to reduce human exposure to air pollutants in residential buildings. However, there is a lack of information on the HRV system performance for controlling both indoor-generated and outdoor-generated particles in a residential building. To fill this knowl-edge gap, we conducted field monitoring of indoor airborne particles with two representative HRV system operating modes (ventilation and circulation modes) in a full-scale residential testbed. The results reveal that the filter efficiency, airflow rate, and filter bypass factor of the HRV system play important roles in indoor particle concentrations. The indoor/outdoor concentration ratio is reduced by 72%-92% when operating the HRV sys-tem. For both circulation and ventilation modes, the bypass factor is crucial for the particle removal performance of the HRV system. A 20% filter bypass factor leads to up to a 50% increase in indoor exposure to outdoor-originated and indoor-generated PM2.5 compared to the no-bypass scenario. Although circulation mode per-formed better than ventilation mode, both operating modes with a minimal bypass factor can effectively remove particles generated from indoor emission sources (e.g., incense stick burning and bacon pan frying). The study results suggest that HRV system can reduce human exposure to indoor-generated particles by 56%-90% and particle control performance hinges upon minimizing HRV filter bypass.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Ventilation and heat preservation effects of heat recovery ventilation system in calf shed
    Chen Z.
    Xu Y.
    Chen Z.
    Zhu Y.
    Feng G.
    An J.
    Liu J.
    Liu, Jijun (liujijun@cau.edu.cn), 1600, Chinese Society of Agricultural Engineering (36): : 219 - 226
  • [22] Performance Analysis of a HVAC System with a Heat Recovery Wheel for a Hospital Building
    Alam, N.
    Mohiuddin, M.
    Sharma, D.
    Patil, S. P.
    Warimani, M.
    Hasan, Z.
    Zaki, S. A.
    Othman, N.
    JOURNAL OF ENGINEERING PHYSICS AND THERMOPHYSICS, 2024, 97 (05) : 1135 - 1142
  • [23] Performance of a natural ventilation system with heat recovery in UK classrooms: An experimental study
    Vivian, Dorizas Paraskevi
    Samuel, Stamp
    Dejan, Mumovic
    Yan Keqin
    Dimitris, Makris-Makridis
    Tom, Lipinski
    ENERGY AND BUILDINGS, 2018, 179 : 278 - 291
  • [24] Human exposure to airborne particles during wood processing
    Gu, Jianwei
    Kirsch, Ina
    Schripp, Tobias
    Froning-Ponndorf, Frank
    Berthold, Dirk
    Salthammer, Tunga
    ATMOSPHERIC ENVIRONMENT, 2018, 193 : 101 - 108
  • [25] Technical and economical analysis of heat recovery in building ventilation systems
    Lazzarin, RM
    Gasparella, A
    APPLIED THERMAL ENGINEERING, 1998, 18 (1-2) : 47 - 67
  • [26] Human exposure to elemental mercury in a contaminated residential building
    Orloff, KG
    Ulirsch, G
    Wilder, L
    Block, A
    Fagliano, J
    Pasqualo, J
    ARCHIVES OF ENVIRONMENTAL HEALTH, 1997, 52 (03): : 169 - 172
  • [27] An investigation of the heat pump performance and ground temperature of a piled foundation heat exchanger system for a residential building
    Wood, Christopher J.
    Liu, Hao
    Riffat, Saffa B.
    ENERGY, 2010, 35 (12) : 4932 - 4940
  • [28] Performance evaluation of hybrid ventilation system for residential buildings
    Yoshino, H.
    Yun, S. H.
    Lee, J. H.
    Wada, J.
    Research in Building Physics and Building Engineering, 2006, : 721 - 729
  • [29] Performance and Optimization for a Ground-Coupled Liquid Loop Heat Recovery Ventilation System
    周亚素
    Per FAHLEN
    Torbjrn LINDHOLM
    JournalofDonghuaUniversity(EnglishEdition), 2007, (06) : 749 - 755
  • [30] Performance and optimization for a ground-coupled liquid loop heat recovery ventilation system
    Ya-Su, Zhou
    Fahlen, Per
    Lindholm, Torbjörn
    Journal of Donghua University (English Edition), 2007, 24 (06) : 749 - 755