Performance of a heat recovery ventilation system for controlling human exposure to airborne particles in a residential building

被引:4
|
作者
Park, Seongjun [1 ]
Lee, Shinhye [2 ]
Yeo, Myoung-Souk [2 ,3 ]
Rim, Donghyun [1 ]
机构
[1] Penn State Univ, Dept Architectural Engn, University Pk, PA 16802 USA
[2] Seoul Natl Univ, Dept Architecture & Architectural Engn, Seoul, South Korea
[3] Seoul Natl Univ, Inst Construct & Environm Engn, Seoul, South Korea
基金
新加坡国家研究基金会; 美国国家科学基金会;
关键词
Indoor air quality; PM2; 5; Exposure control; Indoor emissions; Mass balance model; Bypass factor; PORTABLE AIR CLEANERS; ULTRAFINE PARTICLES; FINE PARTICLES; CONTROL STRATEGIES; SOURCE EMISSION; OUTDOOR; IMPACT; RATES; INFILTRATION; FILTRATION;
D O I
10.1016/j.buildenv.2023.110412
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Heat recovery ventilation (HRV) system is emerging as a sustainable technology to reduce human exposure to air pollutants in residential buildings. However, there is a lack of information on the HRV system performance for controlling both indoor-generated and outdoor-generated particles in a residential building. To fill this knowl-edge gap, we conducted field monitoring of indoor airborne particles with two representative HRV system operating modes (ventilation and circulation modes) in a full-scale residential testbed. The results reveal that the filter efficiency, airflow rate, and filter bypass factor of the HRV system play important roles in indoor particle concentrations. The indoor/outdoor concentration ratio is reduced by 72%-92% when operating the HRV sys-tem. For both circulation and ventilation modes, the bypass factor is crucial for the particle removal performance of the HRV system. A 20% filter bypass factor leads to up to a 50% increase in indoor exposure to outdoor-originated and indoor-generated PM2.5 compared to the no-bypass scenario. Although circulation mode per-formed better than ventilation mode, both operating modes with a minimal bypass factor can effectively remove particles generated from indoor emission sources (e.g., incense stick burning and bacon pan frying). The study results suggest that HRV system can reduce human exposure to indoor-generated particles by 56%-90% and particle control performance hinges upon minimizing HRV filter bypass.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] APPLICATION OF A HEAT PUMP RECOVERY FRESH AIR UNIT IN RESIDENTIAL BUILDING
    Wang, Chunqing
    Ran, Chunyu
    Zhang, Lan
    Ge, Fenghua
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1724 - 1731
  • [32] Efficacy of an ambulance ventilation system in reducing EMS worker exposure to airborne particles from a patient cough aerosol simulator
    Lindsley, William G.
    Blachere, Francoise M.
    McClelland, Tia L.
    Neu, Dylan T.
    Mnatsakanova, Anna
    Martin, Stephen B., Jr.
    Mead, Kenneth R.
    Noti, John D.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2019, : 804 - 816
  • [33] Energy Conservation Analysis of VRV Air Conditioning System with Heat Recovery Ventilation in a Chinese Hotel Building
    Cai, Wei
    Wu, Zhaohui
    Yang, Jian
    Zhang, Qiang
    ACHIEVEMENTS IN ENGINEERING MATERIALS, ENERGY, MANAGEMENT AND CONTROL BASED ON INFORMATION TECHNOLOGY, PTS 1 AND 2, 2011, 171-172 : 150 - +
  • [34] Experimental investigation of a decentralized heat recovery ventilation system
    Pekdogan, Tugce
    Tokuc, Ayca
    Ezan, Mehmet Akif
    Basaran, Tahsin
    JOURNAL OF BUILDING ENGINEERING, 2021, 35
  • [35] HEAT RECOVERY-SYSTEM FOR A NEWSPAPER BUILDING
    不详
    REFRIGERATION AND AIR CONDITIONING, 1974, 77 (912): : 24 - &
  • [36] Experimental investigations on the effectiveness of micro heat pipe array heat exchanger for heat recovery for residential building
    Zhu, ZhongWei
    Fan, HongMing
    Zhang, Cheng
    APPLIED THERMAL ENGINEERING, 2016, 102 : 980 - 988
  • [37] Data-driven modelling of pressurized corridor ventilation system performance in a multi-unit residential building
    Stopps, Helen
    Lozinsky, Cara H.
    Touchie, Marianne F.
    JOURNAL OF BUILDING PHYSICS, 2025,
  • [38] Indoor Environment Control and Energy Saving Performance of a Hybrid. Ventilation System for a Multi-residential Building
    Lim, Young-hoon
    Yun, Hi-won
    Song, Doosam
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 2863 - 2868
  • [39] Design of a Ventilation System Coupled with a Horizontal Air-Ground Heat Exchanger (HAGHE) for a Residential Building in a Warm Climate
    Baglivo, Cristina
    D'Agostino, Delia
    Congedo, Paolo Maria
    ENERGIES, 2018, 11 (08):
  • [40] Experimental investigation into the thermal performance of a residential hybrid ventilation system
    Turner, William J. N.
    Awbi, Hazim B.
    APPLIED THERMAL ENGINEERING, 2015, 77 : 142 - 152