Theoretical Modeling of Surface Plasmon Resonance Biosensor Using Titanium Dioxide and Graphene Nanomaterial for Refractive Index Sensing

被引:2
|
作者
Yadav, Annu [1 ]
Lohia, Pooja [1 ]
Singh, Sachin [2 ]
Yadav, Sapana [3 ]
Mishra, Adarsh Chandra [3 ]
Dwivedi, Dilip Kumar [3 ]
机构
[1] Madan Mohan Malaviya Univ Technol, Dept Elect & Commun Engn, Gorakhpur 273010, India
[2] Inst Adv Mat, IAAM, Gammalkilsvagen, S-59053 Ulrika, Sweden
[3] Madan Mohan Malaviya Univ Technol, Dept Phys & Mat Sci, Photon & Photovolta Res Lab, Gorakhpur 273010, India
关键词
angular sensitivity; biosensors; graphene; refractive index sensors; titanium dioxide; SENSITIVITY-ENHANCEMENT; SPR SENSOR; FOOD;
D O I
10.1002/pssa.202300471
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The most popular method to determine the sensitivity of surface plasmon resonance (SPR) sensors in the last couple of decades has been angular interrogation. The silver layer (Ag), a 2D layer of TiO2, and dielectric material layer such as silicon (Si) with heterostructure material graphene are all stacked in the proposed SPR sensor. To increase sensitivity of SPR sensor in the visible area, the device structure focuses on the Kretschmann configuration, by which a TiO2 sheet is sandwiched between silver and silicon sheets. The proposed device structure makes use of the operational wavelength of 633 nm. The numerical simulation has been performed in MATLAB software in this device structure. The simulation results show that an analyte of refractive indices ranges 1.345-1.350. A single layer of silicon 3 nm and TiO2 10 nm makes up the suggested SPR configuration, which increases the sensitivity to 281 degrees RIU-1. Herein, it has also been computed the figure of merit, detection accuracy, limit of detection, full width at half maximum, and transverse magnetic electric field intensity. The biomedical and chemical fields have benefited from the proposed SPR sensor structure design. A surface plasmon resonance-based sensor has been designed and analyzed theoretically using MATLAB software. The proposed structure offers sensitivity up to 281 deg RIU-1. Performance parameters such as figure of merit, limit of detection and full width at half maxima have also been calculated.image (c) 2023 WILEY-VCH GmbH
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Refractive index sensing using MXene mediated surface plasmon resonance sensor in visible to near infrared regime
    Kumar, Rajeev
    Agarwal, Sajal
    Pal, Sarika
    Verma, Alka
    Prajapati, Yogendra Kumar
    MEASUREMENT, 2024, 224
  • [32] Sensitivity enhancement of surface plasmon resonance biosensor using graphene and air gap
    Verma, Alka
    Prakash, Arun
    Tripathi, Rajeev
    OPTICS COMMUNICATIONS, 2015, 357 : 106 - 112
  • [33] High-Sensitivity Gold-Coated Refractive Index Biosensor Based on Surface Plasmon Resonance
    Abdullah, Hasan
    Uddin, Muhammad Shahin
    Paul, Bikash Kumar
    PLASMONICS, 2023, 18 (06) : 2213 - 2223
  • [34] Refractive index tuning of SiO2 for Long Range Surface Plasmon Resonance based biosensor
    Jain, Surbhi
    Paliwal, Ayushi
    Gupta, Vinay
    Tomar, Monika
    BIOSENSORS & BIOELECTRONICS, 2020, 168
  • [35] High-Sensitivity Gold-Coated Refractive Index Biosensor Based on Surface Plasmon Resonance
    Hasan Abdullah
    Muhammad Shahin Uddin
    Bikash Kumar Paul
    Plasmonics, 2023, 18 : 2213 - 2223
  • [36] Surface plasmon resonance biosensor using inverted graded index optical fiber
    Nasirifar, Ruhallah
    Danaie, Mohammad
    Dideban, Abbas
    PHOTONICS AND NANOSTRUCTURES-FUNDAMENTALS AND APPLICATIONS, 2021, 44
  • [37] Theoretical Analysis of the Propagation of Surface Plasmon Waves in Multilayer Surface Plasmon Resonance Biosensor
    Islam, Md. Saiful
    Kouzani, Abbas Z.
    Coyle, Eugene D.
    2017 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM - SPRING (PIERS), 2017, : 1162 - 1167
  • [38] Sensitivity Enhancement of the Surface Plasmon Resonance Biosensor Based on Hybrid Structure Using MXene and MoS2 for Refractive Index Sensing: An Angular Interrogation Approach
    Ghodrati, Maryam
    Mir, Ali
    Farmani, Ali
    SENSING AND IMAGING, 2024, 25 (01):
  • [39] Theoretical limit of localized surface plasmon resonance sensitivity to local refractive index change and its comparison to conventional surface plasmon resonance sensor
    Zalyubovskiy, Sergiy J.
    Bogdanova, Maria
    Deinega, Alexei
    Lozovik, Yurii
    Pris, Andrew D.
    An, Kwang Hyup
    Hall, W. Paige
    Potyrailo, Radislav A.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2012, 29 (06) : 994 - 1002
  • [40] Gas sensors for refractive index detection using surface plasmon resonance on nanosystem
    Zhao Hua-Jun
    Tian Yong-You
    Lei Ju-Hua
    INTERNATIONAL SYMPOSIUM ON PHOTONICS AND OPTOELECTRONICS 2014, 2014, 9233