Gas sensors for refractive index detection using surface plasmon resonance on nanosystem

被引:2
|
作者
Zhao Hua-Jun [1 ]
Tian Yong-You [1 ]
Lei Ju-Hua [2 ,3 ]
机构
[1] Chongqing Univ Arts & Sci, Coll Mech & Elect Engn, Chongqing 402160, Peoples R China
[2] Chongqing Econ & Trade Secondary Vocat Sch, Dept Elect Informat, Chongqing 402160, Peoples R China
[3] Chongqing Univ Technol, Sch Elect Informat & Automat, Chongqing 400054, Peoples R China
关键词
plasmonic device; gas sensor; resonators; surface plasmon resonance;
D O I
10.1117/12.2068534
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A plasmonic device for gas sensor is investigated for refractive index detection using surface plasmon resonance (SPR). The sensor device consists of nano-cavity antennas formed by metallic rectangular nanostrip array over a metal film, which monitors the changes of the refractive index by measuring the spectral shift of the resonance angle dip. The average detection sensitivity of the gas sensor is about 136 degrees/RIU ( refractive index units) for SPR excitation at 1550 nm telecommunication wavelength.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Surface plasmon resonance based fiber optic refractive index sensors
    Hlubina, Petr
    Kadulova, Miroslava
    Ciprian, Dalibor
    19TH POLISH-SLOVAK-CZECH OPTICAL CONFERENCE ON WAVE AND QUANTUM ASPECTS OF CONTEMPORARY OPTICS, 2014, 9441
  • [2] Low refractive index gas sensing using a surface plasmon resonance fibre device
    Allsop, T.
    Neal, R.
    Davies, E. M.
    Mou, C.
    Bond, P.
    Rehman, S.
    Kalli, K.
    Webb, D. J.
    Calverhouse, P.
    Bennion, I.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (09)
  • [3] Sensitivity Dependence of Surface Plasmon Resonance Based Sensors on Prism Refractive Index
    Wang Guo-ping 1
    2.Department of Applied Physics
    Wuhan University Journal of Natural Sciences, 2002, (01) : 47 - 50
  • [4] Simultaneous Measurement of Refractive Index and Temperature Based on Surface Plasmon Resonance Sensors
    Xiao, Feng
    Michel, David
    Li, Guangyuan
    Xu, Anshi
    Alameh, Kamal
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2014, 32 (21) : 4169 - 4173
  • [5] Sensitivity dependence of surface plasmon resonance based sensors on prism refractive index
    Wang, Guo-Ping
    Sugiura, Tadao
    Kawata, Satoshi
    Wuhan University Journal of Natural Sciences, 2002, 7 (01) : 47 - 50
  • [6] Selective gas detection by means of surface plasmon resonance sensors
    Miwa, S
    Arakawa, T
    THIN SOLID FILMS, 1996, 281 : 466 - 468
  • [7] Determination of refractive index by surface plasmon resonance
    Inst of Electronics, Chinese Acad of Sciences, Beijing, China
    Guangdianzi Jiguang, 1 (40-41):
  • [8] Human Teeth Disease Detection Using Refractive Index Based Surface Plasmon Resonance Biosensor
    Alam, Mohammad Khursheed
    Dhasarathan, Vigneswaran
    Natesan, Ayyanar
    Nambi, Ramanujam
    Zaman, Mahmud Uz
    Ganji, Kiran Kumar
    Basri, Rehana
    Munisekhar, Manay Srinivas
    Nagarajappa, Anil Kumar
    Abutayyem, Huda
    COATINGS, 2022, 12 (10)
  • [9] Measurement of air refractive index based on surface plasmon resonance and phase detection
    Chen, Qianghua
    Luo, Huifu
    Wang, Sumei
    Wang, Feng
    OPTICS LETTERS, 2012, 37 (14) : 2916 - 2918
  • [10] Simultaneous measurement of refractive index and temperature for prism-based surface plasmon resonance sensors
    Lu, Wei
    Wang, Rujing
    Li, Hairong
    Kou, Jieting
    Zeng, Xinhua
    Huang, He
    Hu, Xiaobo
    Huang, Wei
    OPTICS EXPRESS, 2019, 27 (02) : 576 - 589