Theoretical Modeling of Surface Plasmon Resonance Biosensor Using Titanium Dioxide and Graphene Nanomaterial for Refractive Index Sensing

被引:2
|
作者
Yadav, Annu [1 ]
Lohia, Pooja [1 ]
Singh, Sachin [2 ]
Yadav, Sapana [3 ]
Mishra, Adarsh Chandra [3 ]
Dwivedi, Dilip Kumar [3 ]
机构
[1] Madan Mohan Malaviya Univ Technol, Dept Elect & Commun Engn, Gorakhpur 273010, India
[2] Inst Adv Mat, IAAM, Gammalkilsvagen, S-59053 Ulrika, Sweden
[3] Madan Mohan Malaviya Univ Technol, Dept Phys & Mat Sci, Photon & Photovolta Res Lab, Gorakhpur 273010, India
关键词
angular sensitivity; biosensors; graphene; refractive index sensors; titanium dioxide; SENSITIVITY-ENHANCEMENT; SPR SENSOR; FOOD;
D O I
10.1002/pssa.202300471
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The most popular method to determine the sensitivity of surface plasmon resonance (SPR) sensors in the last couple of decades has been angular interrogation. The silver layer (Ag), a 2D layer of TiO2, and dielectric material layer such as silicon (Si) with heterostructure material graphene are all stacked in the proposed SPR sensor. To increase sensitivity of SPR sensor in the visible area, the device structure focuses on the Kretschmann configuration, by which a TiO2 sheet is sandwiched between silver and silicon sheets. The proposed device structure makes use of the operational wavelength of 633 nm. The numerical simulation has been performed in MATLAB software in this device structure. The simulation results show that an analyte of refractive indices ranges 1.345-1.350. A single layer of silicon 3 nm and TiO2 10 nm makes up the suggested SPR configuration, which increases the sensitivity to 281 degrees RIU-1. Herein, it has also been computed the figure of merit, detection accuracy, limit of detection, full width at half maximum, and transverse magnetic electric field intensity. The biomedical and chemical fields have benefited from the proposed SPR sensor structure design. A surface plasmon resonance-based sensor has been designed and analyzed theoretically using MATLAB software. The proposed structure offers sensitivity up to 281 deg RIU-1. Performance parameters such as figure of merit, limit of detection and full width at half maxima have also been calculated.image (c) 2023 WILEY-VCH GmbH
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Surface Plasmon Resonance Biosensor as a Tool for the Measurement of Complex Refractive Indices
    Filion-Cote, Sandrine
    Tabrizian, Maryam
    Kirk, Andrew G.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 6413 - 6416
  • [42] Versatile infrared refractive-index sensor based on surface plasmon resonance in graphene sheet
    Bai, Yukun
    Wang, Biao
    Ma, Xiurong
    OPTICAL ENGINEERING, 2018, 57 (03)
  • [43] Angle modulated surface plasmon resonance spectrometer for refractive index sensing with enhanced detection resolution
    Zhou, Xinlei
    Chen, Ke
    Li, Li
    Peng, Wei
    Yu, Qingxu
    OPTICS COMMUNICATIONS, 2017, 382 : 610 - 614
  • [44] Locally excited surface plasmon resonance for refractive index sensing with high sensitivity and high resolution
    Wang, Xue
    Wang, Chang
    Sun, Xiaojuan
    Li, Xin
    Liu, Hongyao
    Sun, Xuqing
    Wang, Fei
    Lu, Xinchao
    Huang, Chengjun
    OPTICS LETTERS, 2021, 46 (15) : 3625 - 3628
  • [45] Demonstration of Polarization-Independent Surface Plasmon Resonance Polymer Waveguide for Refractive Index Sensing
    Viphavakit, Charusluk
    Patchoo, Wisarn
    Boonruang, Sakoolkan
    Themistos, Christos
    Komodromos, Michael
    Mohammed, Waleed S.
    Rahman, B. M. Azizur
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2017, 35 (14) : 3012 - 3019
  • [46] Refractive index sensing characteristics of dual-core PCF based on surface plasmon resonance
    Guo, Xuan
    Han, Liying
    Liu, Feng
    Li, Shitao
    OPTIK, 2020, 218 (218):
  • [47] Sensitivity enhancement of graphene coated surface plasmon resonance biosensor
    Kamrun Nahar Shushama
    Md. Masud Rana
    Reefat Inum
    Md. Biplob Hossain
    Optical and Quantum Electronics, 2017, 49
  • [48] Investigation of gold-graphene surface plasmon resonance biosensor
    20151900831871
    (1) Nano3 i-kohza, Malaysia- Japan International Institute of Technology (MJIIT), Universiti Teknologi Malaysia, Kuala Lumpur; 54100, Malaysia; (2) Nanotechnology Research Center, Nanoelectronic group, Physics Department, Faculty of Science, Urmia University, Urmia, Iran, 1600, (Optical Society of America):
  • [49] Sensitivity enhancement of graphene coated surface plasmon resonance biosensor
    Shushama, Kamrun Nahar
    Rana, Md Masud
    Inum, Reefat
    Hossain, Md Biplob
    OPTICAL AND QUANTUM ELECTRONICS, 2017, 49 (11)
  • [50] SURFACE PLASMON RESONANCE IMAGING BIOSENSOR BASED ON GRAPHENE MULTILAYER
    Maharana, Pradeep Kumar
    Srivastava, Triranjita
    Jha, Rajan
    2012 INTERNATIONAL CONFERENCE ON FIBER OPTICS AND PHOTONICS (PHOTONICS), 2012,