Spectral analysis of Monte Carlo calculated fluence correction and cema conversion factors for high- energy photon beams at different depths

被引:0
|
作者
Roers, Julian [1 ,2 ]
Czarnecki, Damian [1 ]
Alissa, Mohamad [1 ]
Zink, Klemens [1 ,3 ,4 ]
机构
[1] Univ Appl Sci Giessen, Inst Med Phys & Radiat Protect IMPS, Giessen, Germany
[2] Univ Hosp Munster, Dept Radiotherapy, Munster, Germany
[3] Univ Med Ctr Giessen Marburg, Dept Radiotherapy & Radiooncol, Marburg, Germany
[4] Marburg Iontherapy Ctr MIT, Marburg, Germany
关键词
radiation dosimetry; CEMA; charged particle fluence; detector response; perturbation factor; build-up region; Monte Carlo simulation; REPLACEMENT CORRECTION FACTORS; DETECTOR DOSE-RESPONSE; REFERENCE DOSIMETRY; MEGAVOLTAGE PHOTON; ION CHAMBERS; PERTURBATION; QUALITY;
D O I
10.3389/fphy.2022.1075514
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Purpose: The aim of this study is to investigate the depth-dependent detector response of detailed thimble air-filled ionization chambers by calculating spectral charged particle fluence correction factors at different depths in water. Those spectral correction factors will help to understand, how the detector response varies at different depths and what kind of influences disparate effects have on the spectral detector response.Methods: The cema-approach can be used to obtain spectral charged particle fluence-based correction factors for various measurement conditions by substituting the commonly well-known dose conversion factor with a conversion factor based on the dosimetric quantity cema ( "converted-energy per unit mass "). The resulting spectral fluence correction factors were calculated with the EGSnrc software toolkit and analyzed for two air-filled cylindrical ionization chambers (PTW type 31021 Semiflex 3D, SNC125c (TM)) at different depths in a water phantom irradiated with a 6 MV linear accelerator x-ray spectrum. The ionization chamber models have been stepwise decomposed to investigate the perturbation caused by internal and external effects on the fluence distribution within the detector.Results: Monte Carlo calculated fluence-based perturbation correction factors revealed that for all investigated detectors, considerable fluence disturbances occur, especially in the build-up region of depth-dose curves. Our results have shown that even slight variations in depth can have major consequences on the differential charged particle fluence within the ionization chamber, mainly due to internal cavity-specific effects. Furthermore, the results showed that in the case of relative dose measurements, the depth-depending detector response can significantly differ from unity in a range of 1.4%-2.8% depending on the ionization chamber design.Conclusion: The complexity of different effects on the fluence disturbance could be broken down with regard to their influence on the spectral fluence distribution in the sensitive volume of the investigated detectors. It could be demonstrated, that the displacement of water is a depth-depending effect, which can not be compensated or corrected ideally for each investigated water depth by the shift of the effective point of measurement. Generally, the spectral analysis of those energy-dependent correction factors serves to a deeper understanding of the detector response under various conditions.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Monte Carlo calculated and experimentally determined output correction factors for small field detectors in Leksell Gamma Knife Perfexion beams
    Benmakhlouf, H.
    Johansson, J.
    Paddick, I.
    Andreo, P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (10): : 3959 - 3973
  • [32] ADVANCED KERNEL METHODS VERSUS MONTE CARLO BASED DOSE CALCULATIONS FOR HIGH ENERGY PHOTON BEAMS
    Georg, D.
    Winkler, P.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S59 - S59
  • [33] Monte Carlo simulation of MOSFET detectors for high-energy photon beams using the PENELOPE code
    Panettieri, Vanessa
    Duch, Maria Amor
    Jornet, Nuria
    Ginjaume, Merce
    Carrasco, Pablo
    Badal, Andreu
    Ortega, Xavier
    Ribas, Montserrat
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (01): : 303 - 316
  • [34] Monte Carlo calculated correction factors for diodes and ion chambers in small photon fields (vol 58, pg 2431, 2013)
    Czarnecki, D.
    Zink, K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (03): : 791 - 794
  • [35] The perturbation correction factors for cylindrical ionization chambers in high-energy photon beams
    Yoshiyama F.
    Araki F.
    Ono T.
    Radiological Physics and Technology, 2010, 3 (2) : 159 - 164
  • [36] Recommendations on the step-size artifact of Monte Carlo-calculated photon and electron beam Cherenkov-to-dose conversion factors
    Zlateva, Yana
    Muir, Bryan
    El Naqa, Issam
    Seuntjens, Jan
    MEDICAL PHYSICS, 2019, 46 (11) : 5388 - 5389
  • [37] Experimental and Monte Carlo studies of fluence corrections for graphite calorimetry in low- and high-energy clinical proton beams
    Lourenco, Ana
    Thomas, Russell
    Bouchard, Hugo
    Kacperek, Andrzej
    Vondracek, Vladimir
    Royle, Gary
    Palmans, Hugo
    MEDICAL PHYSICS, 2016, 43 (07) : 4122 - 4132
  • [38] Perturbation correction for alanine dosimeters in different phantom materials in high-energy photon beams
    von Voigts-Rhetz, P.
    Anton, M.
    Vorwerk, H.
    Zink, K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (03): : N70 - N79
  • [39] DOSE CORRECTION FACTORS AT THE BONE-TISSUE INTERFACE FOR HIGH-ENERGY PHOTON BEAMS
    REFT, CS
    KUCHNIR, FT
    MEDICAL PHYSICS, 1986, 13 (04) : 589 - 589
  • [40] Fluence correction factors for graphite calorimetry in a low-energy clinical proton beam: I. Analytical and Monte Carlo simulations
    Palmans, H.
    Al-Sulaiti, L.
    Andreo, P.
    Shipley, D.
    Luehr, A.
    Bassler, N.
    Martinkovic, J.
    Dobrovodsky, J.
    Rossomme, S.
    Thomas, R. A. S.
    Kacperek, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (10): : 3481 - 3499