Miniaturization and Automation Protocol of a Urinary Organic Acid Liquid-Liquid Extraction Method on GC-MS

被引:0
|
作者
Phiri, Masauso Moses [1 ,2 ]
Davoren, Elmarie [2 ]
Vorster, Barend Christiaan [2 ]
机构
[1] Univ Zambia, Sch Med, Dept Pathol & Microbiol, Lusaka 10101, Zambia
[2] North West Univ, Ctr Human Metabol, ZA-2531 Potchefstroom, South Africa
来源
MOLECULES | 2023年 / 28卷 / 15期
关键词
organic acids; liquid-liquid extraction; automation; miniaturization; method validation; METABOLOMICS; SPECTROMETRY;
D O I
10.3390/molecules28155927
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The aim of this study was to improve the extraction method for urinary organic acids by miniaturizing and automating the process. Currently, manual extraction methods are commonly used, which can be time-consuming and lead to variations in test results. To address these issues, we reassessed and miniaturized the in-house extraction method, reducing the number of steps and the sample-to-solvent volumes required. The evaluated miniaturized method was translated into an automated extraction procedure on a MicroLab (ML) Star (Hamilton Technologies) liquid handler. This was then validated using samples obtained from the ERNDIM External Quality Assurance program. The organic acid extraction method was successfully miniaturized and automated using the Autosampler robot. The linear range for most of the thirteen standard analytes fell between 0 to 300 mg/L in spiked synthetic urine, with low (50 mg/L), medium (100 mg/L), and high (500 mg/L) levels. The correlation coefficient (r) for most analytes was >0.99, indicating a strong relationship between the measured values. Furthermore, the automated extraction method demonstrated acceptable precision, as most organic acids had coefficients of variation (CVs) below 20%. In conclusion, the automated extraction method provided comparable or even superior results compared to the current in-house method. It has the potential to reduce solvent volumes used during extraction, increase sample throughput, and minimize variability and random errors in routine diagnostic settings.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Volatile compounds in Cabernet Sauvignon and Cabernet Franc using liquid-liquid extract followed by GC-MS
    Fan Wenlai
    Xu Yan
    Li Jiming
    Zhao Guangao
    Jiang Wenguang
    Proceedings of the Fifth International Symposium on Viticulture and Enology, 2007, : 240 - 246
  • [42] GC-MS profiling of urinary organic acids evaluated as a quantitative method
    Duez, P
    Kumps, A
    Mardens, Y
    CLINICAL CHEMISTRY, 1996, 42 (10) : 1609 - 1615
  • [43] Determination of organophosphate pesticides in sea and surface water with ultrasound-assisted dispersive liquid-liquid micro-extraction coupled to GC-MS/MS analysis
    Habedank, Friederike
    Abraham, Marion
    Tardel, Helmar
    Feldhusen, Frerk
    Schulz-Bull, Detlef E.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2017, 97 (09) : 819 - 830
  • [44] A simple quantitation method for benzoylecgonine from oral fluid, blood, and urine samples used for determining 22 illicit and licit drugs by GC-MS with liquid-liquid extraction
    Institoris, Laszlo
    Angyal, Vilmos
    Arok, Zsofia
    Kereszty, Eva
    Varga, Tibor
    FORENSIC TOXICOLOGY, 2012, 30 (01) : 59 - 65
  • [45] Pesticide Determination in Fresh Coconut Water (Cocos nucifera Linn.) by GC-MS Using Microwave-Assisted Liquid-Liquid Extraction
    Nakamura, Thamilin C.
    do Rego, Enoc L.
    de Souza, Jurandir R.
    Diniz, Paulo H. G. D.
    da Silva, Jose D. S.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2023, 34 (11) : 1707 - 1716
  • [46] Combined cation exchange-liquid-liquid extraction method for GC-MS determination of 4-nonylphenol content in water
    Cruceru, Ioana
    Badea, Irinel Adriana
    Vladescu, Luminita
    REVISTA DE CHIMIE, 2007, 58 (12): : 1305 - 1309
  • [47] METHOD COMPARISON FOR HERBICIDE DETERMINATION IN WATER - GC-MS VERSUS HPLC AND LIQUID LIQUID VERSUS SOLID-PHASE EXTRACTION
    STELLUTO, S
    MARCOMINI, A
    DICORCIA, A
    MARCHETTI, M
    CAPRI, S
    LIBERATORI, A
    ANNALI DI CHIMICA, 1990, 80 (7-8) : 369 - 377
  • [48] Solvent-vapor-assisted liquid-liquid microextraction: A novel method for the determination of phthalate esters in aqueous samples using GC-MS
    Mohebbi, Maryam
    Heydari, Rouhollah
    Ramezani, Majid
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (22) : 4394 - 4402
  • [49] Optimising a urinary extraction method for non-targeted GC-MS metabolomics
    Olivier, Cara
    Allen, Bianca
    Luies, Laneke
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [50] Validation of a GC-MS/MS method for simultaneous determination of 86 persistent organic pollutants in marine sediments by pressurized liquid extraction followed by stir bar sorptive extraction
    Camino-Sanchez, F. J.
    Zafra-Gomez, Alberto
    Perez-Trujillo, J. P.
    Conde-Gonzalez, J. E.
    Marques, J. C.
    Luis Vilchez, Jose
    CHEMOSPHERE, 2011, 84 (07) : 869 - 881