Miniaturization and Automation Protocol of a Urinary Organic Acid Liquid-Liquid Extraction Method on GC-MS

被引:0
|
作者
Phiri, Masauso Moses [1 ,2 ]
Davoren, Elmarie [2 ]
Vorster, Barend Christiaan [2 ]
机构
[1] Univ Zambia, Sch Med, Dept Pathol & Microbiol, Lusaka 10101, Zambia
[2] North West Univ, Ctr Human Metabol, ZA-2531 Potchefstroom, South Africa
来源
MOLECULES | 2023年 / 28卷 / 15期
关键词
organic acids; liquid-liquid extraction; automation; miniaturization; method validation; METABOLOMICS; SPECTROMETRY;
D O I
10.3390/molecules28155927
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The aim of this study was to improve the extraction method for urinary organic acids by miniaturizing and automating the process. Currently, manual extraction methods are commonly used, which can be time-consuming and lead to variations in test results. To address these issues, we reassessed and miniaturized the in-house extraction method, reducing the number of steps and the sample-to-solvent volumes required. The evaluated miniaturized method was translated into an automated extraction procedure on a MicroLab (ML) Star (Hamilton Technologies) liquid handler. This was then validated using samples obtained from the ERNDIM External Quality Assurance program. The organic acid extraction method was successfully miniaturized and automated using the Autosampler robot. The linear range for most of the thirteen standard analytes fell between 0 to 300 mg/L in spiked synthetic urine, with low (50 mg/L), medium (100 mg/L), and high (500 mg/L) levels. The correlation coefficient (r) for most analytes was >0.99, indicating a strong relationship between the measured values. Furthermore, the automated extraction method demonstrated acceptable precision, as most organic acids had coefficients of variation (CVs) below 20%. In conclusion, the automated extraction method provided comparable or even superior results compared to the current in-house method. It has the potential to reduce solvent volumes used during extraction, increase sample throughput, and minimize variability and random errors in routine diagnostic settings.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Simultaneous Determination of Aldrin and Mirex in Honey by Liquid-Liquid Extraction with Low-Temperature Purification combined with GC-MS
    Santos, Silas de Souza
    Pereira de Freitas, Lucas Victor
    Sicupira, Lazaro Chaves
    Silverio, Flaviano Oliveira
    FOOD ANALYTICAL METHODS, 2022, 15 (10) : 2744 - 2755
  • [22] Salting-out assisted liquid-liquid extraction method combined with GC-MS for the determination of topiramate in aqueous solutions: development and application of the methodology
    Ferreira De Almeida, Janiele Mayara
    Fernandes Silva, Elania Maria
    Verissimo, Lourena Mafra
    Fernandes, Nedja Suely
    SEPARATION SCIENCE AND TECHNOLOGY, 2020, 55 (13) : 2303 - 2312
  • [23] Liquid-liquid extraction combined with online cleanup for the simultaneous determination of PAHs by GC-MS/MS and their hydroxylated metabolites by LC-MS/MS in human fingernails
    Zeng, Zihuan
    Gao, Yuan
    Cui, Juntao
    Lin, Meiqing
    Tang, Jian
    Wang, Fei
    Yang, Yan
    Yu, Yingxin
    Ma, Shengtao
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1188
  • [24] Ultrasound-assisted dispersive liquid-liquid microextraction followed by GC-MS/MS analysis for the determination of valproic acid in urine samples
    Jain, Rajeev
    Gupta, Manoj Kumar
    Chauhan, Abhishek
    Pandey, Vivek
    Mudiam, Mohana Krishna Reddy
    Bioanalysis, 2015, 7 (19) : 2451 - 2459
  • [25] Determination of low ppm levels of dimethyl sulfate in an aqueous soluble API intermediate using liquid-liquid extraction and GC-MS
    Zheng, Jie
    Pritts, Wayne A.
    Zhang, Shuhong
    Wittenberger, Steve
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (05) : 1054 - 1059
  • [26] Rapid liquid-liquid extraction for the reliable GC/MS analysis of volatile priority pollutants
    Polyakova, Olga V.
    Mazur, Dmitry M.
    Artaev, Viatcheslav B.
    Lebedev, Albert T.
    ENVIRONMENTAL CHEMISTRY LETTERS, 2016, 14 (02) : 251 - 257
  • [27] Determination of selected amino acids in milk using dispersive liquid-liquid microextraction and GC-MS
    Quigley, Andrew
    Connolly, Damian
    Cummins, Wayne
    ANALYTICAL METHODS, 2019, 11 (28) : 3538 - 3545
  • [28] Multivariate optimization of dispersive liquid-liquid microextraction for the determination of paclobutrazol and triflumizole in water by GC-MS
    Chormey, Dotse Selali
    Karakus, Yesim
    Karayaka, Sena
    Ozsoyler, Cagla
    Bozdogan, Abdurrezzak Emin
    Bakirdere, Sezgin
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (23) : 4541 - 4548
  • [29] Countercurrent liquid/liquid extraction for analysis of organic water pollutants by GC/MS
    Yrieix, C
    Gonzalez, C
    Deroux, JM
    Lacoste, C
    Leybros, J
    WATER RESEARCH, 1996, 30 (08) : 1791 - 1800
  • [30] Determination of organic pollutants in coking wastewater by dispersive liquid-liquid microextraction/GC/MS
    Song, Guoxin
    Zhu, Chunyan
    Hu, Yaoming
    Chen, Jianmin
    Cheng, Hefa
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (9-10) : 1644 - 1651