Improved precision of SPECT myocardial blood flow using a net tracer retention model

被引:4
|
作者
Cuddy-Walsh, Sarah G. [1 ]
deKemp, Robert A. [1 ,2 ]
Ruddy, Terrence D. [1 ,2 ]
Wells, R. Glenn [1 ,2 ,3 ]
机构
[1] Univ Ottawa Heart Inst, Div Cardiol, Ottawa, ON, Canada
[2] Univ Ottawa, Div Cardiol, Ottawa, ON, Canada
[3] Univ Ottawa Heart Inst, Cardiac Imaging HS414, 40 Ruskin St, Ottawa, ON K1Y 4W7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
myocardial blood flow (MBF); myocardial flow reserve (MFR); net tracer retention model; precision; SPECT; tissue compartment model; CORONARY-ARTERY-DISEASE; RB-82; PET; RESERVE; QUANTIFICATION; PERFUSION; TOMOGRAPHY;
D O I
10.1002/mp.16186
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundNoninvasive quantification of absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) provides incremental benefit to relative myocardial perfusion imaging (MPI) to diagnose and manage heart disease. MBF can be measured with single-photon emission computed tomography (SPECT) but the uncertainty in the measured values is high. Standardization and optimization of protocols for SPECT MBF measurements will improve the consistency of this technique. One element of the processing protocol is the choice of kinetic model used to analyze the dynamic image series. PurposeThis study evaluates if a net tracer retention model (RET) will provide a better fit to the acquired data and greater test-retest precision than a one-compartment model (1CM) for SPECT MBF, with (+MC) and without (-MC) manual motion correction. MethodsData from previously acquired rest-stress MBF studies (31 SPECT-PET and 30 SPECT-SPECT) were reprocessed +/- MC. Rate constants (K1) were extracted using 1CM and RET, +/-MC, and compared pairwise with standard PET MBF measurements using cross-validation to obtain calibration parameters for converting SPECT rate constants to MBF and to assess the goodness-of-fit of the calibration curves. Precision (coefficient of variation of test re-test relative differences, COV) of flow measurements was computed for 1CM and RET +/- MC using data from the repeated SPECT MBF studies. ResultsBoth the RET model and MC improved the goodness-of-fit of the SPECT MBF calibration curves to PET. All models produced minimal bias compared with PET (mean bias < 0.6%). The SPECT-SPECT MBF COV significantly improved from 34% (1CM+MC) to 28% (RET+MC, P = 0.008). ConclusionThe RET+MC model provides a better calibration of SPECT to PET and blood flow measurements with better precision than the 1CM, without loss of accuracy.
引用
收藏
页码:2009 / 2021
页数:13
相关论文
共 50 条
  • [41] Are SPECT measurements of myocardial blood flow and flow reserve ready for clinical use?
    Garcia, Ernest V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (12) : 2291 - 2293
  • [42] Comparison of dynamic SPECT Myocardial Blood Flow and Flow Reserve with regadenoson and dipyridamole
    Bailly, M.
    Brana, Q.
    Thibault, F.
    Courtehoux, M.
    Metrard, G.
    Angoulvant, D.
    Ribeiro, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S328 - S329
  • [43] PHYSIOLOGY AND THEORY OF TRACER WASHOUT TECHNIQUES FOR ESTIMATION OF MYOCARDIAL BLOOD-FLOW - FLOW ESTIMATION FROM TRACER WASHOUT
    BASSINGTHWAIGHTE, JB
    PROGRESS IN CARDIOVASCULAR DISEASES, 1977, 20 (03) : 165 - 189
  • [44] A method to measure the extent of myocardial ischemia and steal with SPECT myocardial blood flow quantitation
    Chen, Lung-Ching
    Hung, Huei-Fong
    Jong, Bor-Hsin
    Lin, Sheng-Che
    Yeh, Chia-lu
    Ku, Chi-Tai
    Chen, Yen-Kung
    Hsu, Bailing
    ANNALS OF NUCLEAR MEDICINE, 2020, 34 (09) : 682 - 690
  • [45] A method to measure the extent of myocardial ischemia and steal with SPECT myocardial blood flow quantitation
    Lung-Ching Chen
    Huei-Fong Hung
    Bor-Hsin Jong
    Sheng-Che Lin
    Chia-lu Yeh
    Chi-Tai Ku
    Yen-Kung Chen
    Bailing Hsu
    Annals of Nuclear Medicine, 2020, 34 : 682 - 690
  • [46] Quantification of myocardial blood flow using 13N-ammonia and PET:: Comparison of tracer models
    Choi, Y
    Huang, SC
    Hawkins, RA
    Kim, JY
    Kim, BT
    Hoh, CK
    Chen, K
    Phelps, ME
    Schelbert, HR
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (06) : 1045 - 1055
  • [47] Radiodosimetry of 123I-CMICE-013, a novel SPECT myocardial perfusion imaging tracer, using a porcine model
    Wells, R. Glenn
    Soueidan, Karen
    Fernando, Pasan
    Lockwood, Julia
    Marvin, Brian
    Wei, Lihui
    Duan, Daniel
    Bensimon, Corinne
    Ruddy, Terrence
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [48] Myocardial blood flow quantification with SPECT and conventional tracers: a critical appraisal
    Stephan G. Nekolla
    Christoph Rischpler
    Kenichi Nakajima
    Journal of Nuclear Cardiology, 2014, 21 : 1089 - 1091
  • [49] Dual-spillover correction for SPECT myocardial blood flow measurement
    Wells, Glenn
    Renaud, Jennifer
    deKemp, Robert
    Ruddy, Terrence
    MEDICAL PHYSICS, 2017, 44 (08) : 4398 - 4398
  • [50] Myocardial blood flow quantification with SPECT and conventional tracers: a critical appraisal
    Nekolla, Stephan G.
    Rischpler, Christoph
    Nakajima, Kenichi
    JOURNAL OF NUCLEAR CARDIOLOGY, 2014, 21 (06) : 1089 - 1091