Quantification of myocardial blood flow using 13N-ammonia and PET:: Comparison of tracer models

被引:0
|
作者
Choi, Y
Huang, SC
Hawkins, RA
Kim, JY
Kim, BT
Hoh, CK
Chen, K
Phelps, ME
Schelbert, HR
机构
[1] Sungkyunkwan Univ, Sch Med, Dept Nucl Med, Samsung Med Ctr, Seoul 135230, South Korea
[2] Univ Calif Los Angeles, Sch Med, Div Nucl Med & Biophys, Dept Mol & Med Pharmacol, Los Angeles, CA USA
关键词
myocardial blood flow; N-13-ammonia; PET; tracer kinetic methods;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Several tracer kinetic methods have been proposed for quantification of regional myocardia[ blood flow (MBF) with N-13-ammonia and PET. Merits and limitations specific to each approach, however, generally are not clear, because they have not been evaluated in the same experimental environment. Therefore, we compared six different commonly used methods (11 modifications) to characterize the accuracy of each approach. The methods included the two-parameter model (method 1), the modified two-parameter model (method 2), the four-parameter model (method 3), the graphical analysis (method 4), the first-pass extraction method (method 5) and the dose uptake index (DUI; method 6). Methods: Eleven studies in four dogs, 16 studies in eight healthy human volunteers and 14 studies in seven patients were performed using N-13-ammonia and PET. MBF in dogs was varied with dipyridamole and coronary occlusions and was measured independently and simultaneously with microspheres. Volunteers and patients were studied at baseline and after dipyridamole. MBF and DUI were estimated using a time-activity curve (Q(i)[t]) derived from dynamic images and regions of interest (ROIs) and using the six methods. DUI was defined as Q(i)(t = 2 min) x weight/dose. Results: MBF estimated by methods 1-5 correlated well with microsphere MBF in dogs. MBF estimates by method 1 correlated well with those by methods 2, 4 and 5 and to a lesser degree with those by method 3 in both dog and human studies. DUI correlated poorly with MBF by microspheres and by methods 1-5 in both dog and human studies. MBF estimates by method 3 showed larger dispersion (SD/mean flow) and higher sensitivity to metabolites correction in arterial blood than those by methods 1, 2, 4 and 5. Conclusion: MBF can be measured accurately using N-13-ammonia PET and tracer kinetic methods. DUI is a poor indicator of MBF values. The results indicate that preference should be given to the two-parameter model, incorporating geometrical ROI representation (method 2) among the compartment models, and to the graphical analysis (method 4) among the noncompartmental approaches.
引用
收藏
页码:1045 / 1055
页数:11
相关论文
共 50 条
  • [1] Validation of an axially distributed model for quantification of myocardial blood flow using 13N-ammonia PET
    Alessio, Adam M.
    Bassingthwaighte, James B.
    Glenny, Robb
    Caldwell, James H.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (01) : 64 - 75
  • [2] Effect of temporal sampling protocols on myocardial blood flow quantification using 13N-ammonia PET
    Hu, Yingqi
    Wang, Ruonan
    Zhang, Chuxin
    Li, Yuanyuan
    Wang, Yanhui
    Diao, Xin
    Zhang, Jun
    Jia, Yanni
    Li, Sijin
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [3] Validation of an axially distributed model for quantification of myocardial blood flow using 13N-ammonia PET
    Adam M. Alessio
    James B. Bassingthwaighte
    Robb Glenny
    James H. Caldwell
    Journal of Nuclear Cardiology, 2013, 20 : 64 - 75
  • [4] Absolute quantification of myocardial blood flow with 13N-ammonia and 3-dimensional PET
    Schepis, Tiziano
    Gaemperli, Oliver
    Treyer, Valerie
    Valenta, Ines
    Burger, Cyrill
    Koepfli, Pascal
    Namdar, Mehdi
    Adachi, Itaru
    Alkadhi, Hatem
    Kaufmann, Philipp A.
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (11) : 1783 - 1789
  • [5] Quantifying the normal range of myocardial blood flow with 13N-ammonia PET and tracer kinetic modeling
    Renaud, Jennifer M.
    Lortie, Mireille
    Wassenaar, Richard W.
    DaSilva, Jean
    Beanlands, Robert S.
    deKemp, Robert A.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1686 - 1690
  • [6] Evaluation of myocardial blood flow in patients with myocardial bridging: A 13N-ammonia PET study
    Monroy-Gonzalez, A.
    Juarez-Orozco, L.
    Berrios-Barcenas, E.
    Gonzalez-Padilla, C.
    Martinez-Aguilar, M.
    Guinto-Nishimura, G.
    Dierckx, R.
    Tio, R.
    Slart, R. H. J. A.
    Alexanderson, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S520 - S521
  • [7] The reproducibility of time-of-flight PET and conventional PET for the quantification of myocardial blood flow and coronary flow reserve with 13N-ammonia
    Masaya Suda
    Masahisa Onoguchi
    Takeshi Tomiyama
    Keiichi Ishihara
    Naoto Takahashi
    Minoru Sakurai
    Keiichi Matsumoto
    Shin-ichiro Kumita
    Journal of Nuclear Cardiology, 2016, 23 : 457 - 472
  • [8] The reproducibility of time-of-flight PET and conventional PET for the quantification of myocardial blood flow and coronary flow reserve with 13N-ammonia
    Suda, Masaya
    Onoguchi, Masahisa
    Tomiyama, Takeshi
    Ishihara, Keiichi
    Takahashi, Naoto
    Sakurai, Minoru
    Matsumoto, Keiichi
    Kumita, Shin-ichiro
    JOURNAL OF NUCLEAR CARDIOLOGY, 2016, 23 (03) : 457 - 472
  • [9] Effect of reconstruction algorithms on myocardial blood flow measurement with 13N-ammonia PET
    Chen, Grace P.
    Branch, Kelley R.
    Alessio, Adam M.
    Pham, Pam
    Tabibiazar, Ramin
    Kinahan, Paul
    Caldwell, James H.
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (08) : 1259 - 1265
  • [10] Software reproducibility of myocardial blood flow and flow reserve quantification in ischemic heart disease: A 13N-ammonia PET study
    Andrea G. Monroy-Gonzalez
    Luis Eduardo Juarez-Orozco
    Chunlei Han
    Issi R. Vedder
    David Vállez García
    Ronald Borra
    Piotr J. Slomka
    Sergey V. Nesterov
    Juhani Knuuti
    Riemer H. J. A. Slart
    Erick Alexanderson-Rosas
    Journal of Nuclear Cardiology, 2020, 27 : 1225 - 1233