Validation of an axially distributed model for quantification of myocardial blood flow using 13N-ammonia PET

被引:12
|
作者
Alessio, Adam M. [1 ]
Bassingthwaighte, James B. [1 ,2 ]
Glenny, Robb [3 ,4 ,5 ]
Caldwell, James H. [1 ,2 ,3 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[2] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[3] Univ Washington, Dept Med, Seattle, WA 98195 USA
[4] Univ Washington, Dept Physiol, Seattle, WA 98195 USA
[5] Univ Washington, Dept Biophys, Seattle, WA 98195 USA
关键词
Myocardial blood flow; cardiac PET; quantitative PET; dynamic imaging; NH3; N-13; AMMONIA; KINETIC-MODEL; PERFUSION; NITROGEN-13-AMMONIA; MICROSPHERES; HEART;
D O I
10.1007/s12350-012-9632-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Estimation of myocardial blood flow (MBF) with cardiac PET is often performed with conventional compartmental models. In this study, we developed and evaluated a physiologically and anatomically realistic axially distributed model. Unlike compartmental models, this axially distributed approach models both the temporal and the spatial gradients in uptake and retention along the capillary. We validated PET-derived flow estimates with microsphere studies in 19 (9 rest, 10 stress) studies in five dogs. The radiotracer, N-13-ammonia, was injected intravenously while microspheres were administered into the left atrium. A regional reduction in hyperemic flow was forced by an external occluder in five of the stress studies. The flow estimates from the axially distributed model were compared with estimates from conventional compartmental models. The mean difference between microspheres and the axially distributed blood flow estimates in each of the 17 segments was 0.03 mL/g/minute (95% CI [-0.05, 0.11]). The blood flow estimates were highly correlated with each regional microsphere value for the axially distributed model (y = 0.98x + 0.06 mL/g/minute; r = 0.74; P < .001), for the two-compartment (y = 0.64x + 0.34; r = 0.74; P < .001), and for three-compartment model (y = 0.69x + 0.54; r = 0.74; P < .001). The variance of the error of the estimates is higher with the axially distributed model than the compartmental models (1.7 [1.3, 2.1] times higher). The proposed axially distributed model provided accurate regional estimates of MBF. The axially distributed model estimated blood flow with more accuracy, but less precision, than the evaluated compartmental models.
引用
收藏
页码:64 / 75
页数:12
相关论文
共 50 条
  • [1] Validation of an axially distributed model for quantification of myocardial blood flow using 13N-ammonia PET
    Adam M. Alessio
    James B. Bassingthwaighte
    Robb Glenny
    James H. Caldwell
    Journal of Nuclear Cardiology, 2013, 20 : 64 - 75
  • [2] Quantification of myocardial blood flow using 13N-ammonia and PET:: Comparison of tracer models
    Choi, Y
    Huang, SC
    Hawkins, RA
    Kim, JY
    Kim, BT
    Hoh, CK
    Chen, K
    Phelps, ME
    Schelbert, HR
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (06) : 1045 - 1055
  • [3] Effect of temporal sampling protocols on myocardial blood flow quantification using 13N-ammonia PET
    Hu, Yingqi
    Wang, Ruonan
    Zhang, Chuxin
    Li, Yuanyuan
    Wang, Yanhui
    Diao, Xin
    Zhang, Jun
    Jia, Yanni
    Li, Sijin
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [4] Absolute quantification of myocardial blood flow with 13N-ammonia and 3-dimensional PET
    Schepis, Tiziano
    Gaemperli, Oliver
    Treyer, Valerie
    Valenta, Ines
    Burger, Cyrill
    Koepfli, Pascal
    Namdar, Mehdi
    Adachi, Itaru
    Alkadhi, Hatem
    Kaufmann, Philipp A.
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (11) : 1783 - 1789
  • [5] Evaluation of myocardial blood flow in patients with myocardial bridging: A 13N-ammonia PET study
    Monroy-Gonzalez, A.
    Juarez-Orozco, L.
    Berrios-Barcenas, E.
    Gonzalez-Padilla, C.
    Martinez-Aguilar, M.
    Guinto-Nishimura, G.
    Dierckx, R.
    Tio, R.
    Slart, R. H. J. A.
    Alexanderson, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S520 - S521
  • [6] The reproducibility of time-of-flight PET and conventional PET for the quantification of myocardial blood flow and coronary flow reserve with 13N-ammonia
    Masaya Suda
    Masahisa Onoguchi
    Takeshi Tomiyama
    Keiichi Ishihara
    Naoto Takahashi
    Minoru Sakurai
    Keiichi Matsumoto
    Shin-ichiro Kumita
    Journal of Nuclear Cardiology, 2016, 23 : 457 - 472
  • [7] The reproducibility of time-of-flight PET and conventional PET for the quantification of myocardial blood flow and coronary flow reserve with 13N-ammonia
    Suda, Masaya
    Onoguchi, Masahisa
    Tomiyama, Takeshi
    Ishihara, Keiichi
    Takahashi, Naoto
    Sakurai, Minoru
    Matsumoto, Keiichi
    Kumita, Shin-ichiro
    JOURNAL OF NUCLEAR CARDIOLOGY, 2016, 23 (03) : 457 - 472
  • [8] Effect of reconstruction algorithms on myocardial blood flow measurement with 13N-ammonia PET
    Chen, Grace P.
    Branch, Kelley R.
    Alessio, Adam M.
    Pham, Pam
    Tabibiazar, Ramin
    Kinahan, Paul
    Caldwell, James H.
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (08) : 1259 - 1265
  • [9] Software reproducibility of myocardial blood flow and flow reserve quantification in ischemic heart disease: A 13N-ammonia PET study
    Andrea G. Monroy-Gonzalez
    Luis Eduardo Juarez-Orozco
    Chunlei Han
    Issi R. Vedder
    David Vállez García
    Ronald Borra
    Piotr J. Slomka
    Sergey V. Nesterov
    Juhani Knuuti
    Riemer H. J. A. Slart
    Erick Alexanderson-Rosas
    Journal of Nuclear Cardiology, 2020, 27 : 1225 - 1233
  • [10] Quantification of the normal range of myocardial blood flow and flow reserve with 82rubidium versus 13N-ammonia PET
    Renaud, Jennifer M.
    Lortie, Mireille
    DaSilva, Jean
    Beanlands, Robert S.
    DeKemp, Robert A.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3141 - +