Validation of an axially distributed model for quantification of myocardial blood flow using 13N-ammonia PET

被引:12
|
作者
Alessio, Adam M. [1 ]
Bassingthwaighte, James B. [1 ,2 ]
Glenny, Robb [3 ,4 ,5 ]
Caldwell, James H. [1 ,2 ,3 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[2] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[3] Univ Washington, Dept Med, Seattle, WA 98195 USA
[4] Univ Washington, Dept Physiol, Seattle, WA 98195 USA
[5] Univ Washington, Dept Biophys, Seattle, WA 98195 USA
关键词
Myocardial blood flow; cardiac PET; quantitative PET; dynamic imaging; NH3; N-13; AMMONIA; KINETIC-MODEL; PERFUSION; NITROGEN-13-AMMONIA; MICROSPHERES; HEART;
D O I
10.1007/s12350-012-9632-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Estimation of myocardial blood flow (MBF) with cardiac PET is often performed with conventional compartmental models. In this study, we developed and evaluated a physiologically and anatomically realistic axially distributed model. Unlike compartmental models, this axially distributed approach models both the temporal and the spatial gradients in uptake and retention along the capillary. We validated PET-derived flow estimates with microsphere studies in 19 (9 rest, 10 stress) studies in five dogs. The radiotracer, N-13-ammonia, was injected intravenously while microspheres were administered into the left atrium. A regional reduction in hyperemic flow was forced by an external occluder in five of the stress studies. The flow estimates from the axially distributed model were compared with estimates from conventional compartmental models. The mean difference between microspheres and the axially distributed blood flow estimates in each of the 17 segments was 0.03 mL/g/minute (95% CI [-0.05, 0.11]). The blood flow estimates were highly correlated with each regional microsphere value for the axially distributed model (y = 0.98x + 0.06 mL/g/minute; r = 0.74; P < .001), for the two-compartment (y = 0.64x + 0.34; r = 0.74; P < .001), and for three-compartment model (y = 0.69x + 0.54; r = 0.74; P < .001). The variance of the error of the estimates is higher with the axially distributed model than the compartmental models (1.7 [1.3, 2.1] times higher). The proposed axially distributed model provided accurate regional estimates of MBF. The axially distributed model estimated blood flow with more accuracy, but less precision, than the evaluated compartmental models.
引用
收藏
页码:64 / 75
页数:12
相关论文
共 50 条
  • [21] Acquisition of dynamic N-13 ammonia PET for myocardial blood flow quantification
    Kyeong Won Kang
    Jong Sang Kim
    Sang-Geon Cho
    Jahae Kim
    Ho-Chun Song
    Journal of Nuclear Cardiology, 2020, 27 : 1288 - 1292
  • [22] HUMAN 13N-AMMONIA PET STUDIES: THE IMPORTANCE OF MEASURING 13N-AMMONIA METABOLITES IN BLOOD
    Sorensen, M.
    Keiding, S.
    Munk, O. L.
    Bender, D.
    JOURNAL OF HEPATOLOGY, 2010, 52 : S216 - S216
  • [23] Quantification of myocardial blood flow with 13N-ammonia and 82Rb PET-OSEM vs. FBP reconstruction
    Davies, R. W.
    Renaud, J. M.
    Beanlands, R. S.
    deKemp, R. A.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2117 - 2119
  • [24] Endothelial dysfunction in obese patients without cardiovascular risk factors: evaluation with 13n-ammonia PET myocardial blood flow quantification
    Alexanderson Rosas, E.
    Jacome, R.
    Jimenez-Santos, M.
    Romero, E.
    Pena-Cabral, M. A.
    Meave, A.
    Gonzalez, J.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A17 - A17
  • [25] SPECT myocardial blood flow quantitation toward clinical use: a comparative study with 13N-Ammonia PET myocardial blood flow quantitation
    Bailing Hsu
    Lien-Hsin Hu
    Bang-Hung Yang
    Lung-Ching Chen
    Yen-Kung Chen
    Chien-Hsin Ting
    Guang-Uei Hung
    Wen-Sheng Huang
    Tao-Cheng Wu
    European Journal of Nuclear Medicine and Molecular Imaging, 2017, 44 : 117 - 128
  • [26] SPECT myocardial blood flow quantitation toward clinical use: a comparative study with 13N-Ammonia PET myocardial blood flow quantitation
    Hsu, Bailing
    Hu, Lien-Hsin
    Yang, Bang-Hung
    Chen, Lung-Ching
    Chen, Yen-Kung
    Ting, Chien-Hsin
    Hung, Guang-Uei
    Huang, Wen-Sheng
    Wu, Tao-Cheng
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 (01) : 117 - 128
  • [27] Validation of axially-distributed models for myocardial blood flow estimation from N-13 ammonia and Rb-82 cardiac PET imaging
    Alessio, A. M.
    Patel, A.
    Lautamaki, R.
    Bengel, F. M.
    Bassingthwaighte, J. B.
    Caldwell, J. H.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A20 - A20
  • [28] Normal value of myocardial blood flow and myocardial flow reserve evaluated by 3-dimensional dynamic PET with 13N-ammonia
    Kiso, Keisuke
    Shimosegawa, Eku
    Kanai, Yasukazu
    Fujino, Koichi
    Hatazawa, Jun
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [29] Absolute myocardial blood flow evaluation with 13N-ammonia and 3D PET-CT
    Leccisotti, L.
    Indovina, L.
    Paraggio, L.
    Calcagni, M. L.
    Giordano, A.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A80 - A80
  • [30] Characterizing the normal range of myocardial blood flow with 82rubidium and 13N-ammonia PET imaging
    Renaud, Jennifer M.
    DaSilva, Jean N.
    Beanlands, Rob S. B.
    deKemp, Robert A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (04) : 578 - 591