摘要
BackgroundNoninvasive quantification of absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) provides incremental benefit to relative myocardial perfusion imaging (MPI) to diagnose and manage heart disease. MBF can be measured with single-photon emission computed tomography (SPECT) but the uncertainty in the measured values is high. Standardization and optimization of protocols for SPECT MBF measurements will improve the consistency of this technique. One element of the processing protocol is the choice of kinetic model used to analyze the dynamic image series. PurposeThis study evaluates if a net tracer retention model (RET) will provide a better fit to the acquired data and greater test-retest precision than a one-compartment model (1CM) for SPECT MBF, with (+MC) and without (-MC) manual motion correction. MethodsData from previously acquired rest-stress MBF studies (31 SPECT-PET and 30 SPECT-SPECT) were reprocessed +/- MC. Rate constants (K1) were extracted using 1CM and RET, +/-MC, and compared pairwise with standard PET MBF measurements using cross-validation to obtain calibration parameters for converting SPECT rate constants to MBF and to assess the goodness-of-fit of the calibration curves. Precision (coefficient of variation of test re-test relative differences, COV) of flow measurements was computed for 1CM and RET +/- MC using data from the repeated SPECT MBF studies. ResultsBoth the RET model and MC improved the goodness-of-fit of the SPECT MBF calibration curves to PET. All models produced minimal bias compared with PET (mean bias < 0.6%). The SPECT-SPECT MBF COV significantly improved from 34% (1CM+MC) to 28% (RET+MC, P = 0.008). ConclusionThe RET+MC model provides a better calibration of SPECT to PET and blood flow measurements with better precision than the 1CM, without loss of accuracy.
引用
收藏
页码:2009 / 2021
页数:13
相关论文
共 50 条
  • [31] Absolute myocardial blood flow quantification with SPECT/CT: Is it possible?
    Piotr J. Slomka
    Daniel S. Berman
    Guido Germano
    Journal of Nuclear Cardiology, 2014, 21 : 1092 - 1095
  • [32] Myocardial blood flow assessment with SPECT systems: The renovation continues
    Kovalski, Gil
    Sharir, Tali
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (06) : 2303 - 2305
  • [33] Respiratory Motion Alters Measurement of SPECT Myocardial Blood Flow
    Wells, R. Glenn
    Ruddy, Terrence
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [34] SPECT imaging of teboroxime during myocardial blood flow changes
    Di Bella, EVR
    Khare, HS
    Kadrmas, DJ
    Gullberg, GT
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 982 - 988
  • [35] SPECT imaging of teboroxime during myocardial blood flow changes
    Di Bella, E.V.R.
    Khare, H.S.
    Kadrmas, D.J.
    Gullberg, G.T.
    IEEE Transactions on Nuclear Science, 2000, 47 (3 III) : 982 - 988
  • [36] SPECT Findings of Abnormal Myocardial Blood Flow in Patients with a Pacemaker
    Tanaka, R.
    Nakamura, T.
    Chiba, S.
    Seino, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S255 - S255
  • [37] Are SPECT measurements of myocardial blood flow and flow reserve ready for clinical use?
    Ernest V. Garcia
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 2291 - 2293
  • [38] SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits
    Chen, Lung-Ching
    Lin, Chih-Yuan
    Chen, Ing-Jou
    Ku, Chi-Tai
    Chen, Yen-Kung
    Hsu, Bailing
    CLINICAL NUCLEAR MEDICINE, 2016, 41 (01) : e60 - e62
  • [39] SPECT measurements of myocardial blood flow and flow reserve: from development to implementation
    Andrew Van Tosh
    Kenneth J. Nichols
    Journal of Nuclear Cardiology, 2023, 30 : 1437 - 1442
  • [40] SPECT measurements of myocardial blood flow and flow reserve: from development to implementation
    Van Tosh, Andrew
    Nichols, Kenneth J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (04) : 1437 - 1442