Preclinical evaluation of semi-automated laser ablation for pulmonary vein isolation: A comparative study

被引:1
|
作者
Kuroki, Kenji [1 ]
Reddy, Vivek Y. [1 ]
Iwasawa, Jin [1 ]
Kawamura, Iwanari [1 ]
Neuzil, Petr [2 ]
Estabrook, Brian [3 ]
Melsky, Gerald [3 ]
Dukkipati, Srinivas R. [1 ]
Koruth, Jacob [1 ,4 ]
机构
[1] Icahn Sch Med Mt Sinai, Helmsley Electrophysiol Ctr, New York, NY USA
[2] Hosp Na Homolce, Dept Cardiol, Prague, Czech Republic
[3] CardioFocus Inc, Marlborough, MA USA
[4] Icahn Sch Med Mt Sinai, Helmsley Electrophysiol Ctr, One Gustave L Levy Pl,POB 1030, New York, NY 10029 USA
关键词
atrial fibrillation; automated; catheter ablation; endoscopic; laser balloon; POINT-BY-POINT; CATHETER ABLATION; PAROXYSMAL AF; MULTICENTER; BALLOON; TRIAL;
D O I
10.1111/jce.15777
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionVisually-guided laser balloon ablation (VGLA) currently requires careful manual rotation of the laser to create overlapping lesions. A novel semi-automated VGLA may reduce ablation times and lesion gaps. We aimed to compare semi-automated (SA) VGLA to that of manual (MN) VGLA. MethodsAcute: Nine swine underwent right superior pulmonary vein isolation (PVI) using either SA (n = 3, 13-18 W), MN (n = 3, 8.5-12 W), or radiofrequency (RF, n = 3, 25-40 W) and were killed acutely. Chronic: 16 swine, underwent PVI using either SA (n = 8, 15 W) or MN (n = 8, 10 W), and were survived for 1 month before being killed. All hearts were then submitted for pathological evaluation. ResultsAcute: PVI was successful in all 9/9 swine with lesion counts significantly lower in the SA arm (5.3 +/- 5.9, 33.7 +/- 10.0, and 28.0 +/- 4.4 in SA, MN, and RF arms; p = .007 for SA and MN). At necropsy, circumferentiality and transmurality were 98% and 94% in SA, 98% and 80% in MN, and 100% and 100% in RF arms. A single steam pop was noted on sectioning in the SA arm swine and occurred in the high dose (18 W) strategy. Chronic: PVI was acutely successful in 16/16 swine with no difference in PVI durability rates (62.5% vs. 75.0%), lesion transmurality (95.8 +/- 17.4% vs.91.9 +/- 25.9%), and circumferentiality (95.8 +/- 6.6% vs. 94.8 +/- 6.3%) between SA and MN arms. Catheter use time and lesion counts were lower in the SA arm compared to the MN arm (11.5 +/- 12.7 vs. 21.8 +/- 3.8 min, p = .046 and 4.8 +/- 3.83 vs. 35.4 +/- 4.4, p < .001). ConclusionMotor-assisted semi-automated laser balloon ablation can improve upon procedural efficiency by reducing ablation time.
引用
收藏
页码:315 / 324
页数:10
相关论文
共 50 条
  • [41] First Belgian experience with the Endoscopic laser balloon Ablation System for pulmonary vein isolation
    Koopman, Pieter
    ten Haken, Jeff
    Vanduynhoven, Philippe
    Dilling, Dagmara
    Schurmans, Joris
    Heidbuchel, Hein
    Vijgen, Johan
    ACTA CARDIOLOGICA, 2016, 71 (01) : 81 - 82
  • [42] First Belgian Experience with the Endoscopic Laser Balloon Ablation System for Pulmonary Vein Isolation
    Koopman, Pieter
    Ten Haken, Jeff
    Vanduynhoven, Philippe
    Dilling, Dagmara
    Schurmans, Joris
    Heidbuchel, Hein
    Vijgen, Johan
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (05) : 643 - 644
  • [43] Pulmonary Vein Isolation Using Laser Balloon as Compared to Standard Radiofrequency Catheter Ablation
    Koopman, Pieter
    Vanhentenrijk, Simon
    Schurmans, Joris
    Dilling, Dagmara
    Vijgen, Johan
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (05) : 600 - 601
  • [44] SEMI-AUTOMATED TREATMENT OF A PHOBIA - CASE STUDY
    MCGLYNN, FD
    OBRIEN, L
    JOURNAL OF CLINICAL PSYCHOLOGY, 1972, 28 (02) : 228 - &
  • [45] Interscan variation of semi-automated volumetry of subsolid pulmonary nodules
    Scholten, Ernst Th
    de Jong, Pim A.
    Jacobs, Colin
    van Ginneken, Bram
    van Riel, Sarah
    Willemink, Martin J.
    Vliegenthart, Rozemarijn
    Oudkerk, Matthijs
    de Koning, Harry J.
    Horeweg, Nanda
    Prokop, Mathias
    Mali, Willem P. Th. M.
    Gietema, Hester A.
    EUROPEAN RADIOLOGY, 2015, 25 (04) : 1040 - 1047
  • [46] Semi-Automated Approach for the Evaluation of Osteoporosis with Forearm Radiographs
    Acharya, Manish
    Kumar, D. Ashok
    2017 INTERNATIONAL CONFERENCE ON COMMUNICATION AND SIGNAL PROCESSING (ICCSP), 2017, : 655 - 659
  • [47] Establishment and Evaluation of a Semi-Automated Data Extraction Methodology
    McPherson, Katherine
    Harandi, Arshia
    Gutierrez, Rodrigo
    Chao, Jerry
    ANESTHESIA AND ANALGESIA, 2023, 136 : 996 - 996
  • [48] Evaluation of a semi-automated clinical decision support system
    Dahmke, H.
    Fiumefreddo, R.
    Zaugg, C.
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACY, 2022, 44 (06) : 1472 - 1472
  • [49] Interscan variation of semi-automated volumetry of subsolid pulmonary nodules
    Ernst Th. Scholten
    Pim A. de Jong
    Colin Jacobs
    Bram van Ginneken
    Sarah van Riel
    Martin J. Willemink
    Rozemarijn Vliegenthart
    Matthijs Oudkerk
    Harry J. de Koning
    Nanda Horeweg
    Mathias Prokop
    Willem P. Th. M. Mali
    Hester A. Gietema
    European Radiology, 2015, 25 : 1040 - 1047
  • [50] Cementochronology (TCA): Evaluation of a semi-automated counting software
    Kuenzie, Melanie
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2013, 150 : 174 - 174