Preclinical evaluation of semi-automated laser ablation for pulmonary vein isolation: A comparative study

被引:1
|
作者
Kuroki, Kenji [1 ]
Reddy, Vivek Y. [1 ]
Iwasawa, Jin [1 ]
Kawamura, Iwanari [1 ]
Neuzil, Petr [2 ]
Estabrook, Brian [3 ]
Melsky, Gerald [3 ]
Dukkipati, Srinivas R. [1 ]
Koruth, Jacob [1 ,4 ]
机构
[1] Icahn Sch Med Mt Sinai, Helmsley Electrophysiol Ctr, New York, NY USA
[2] Hosp Na Homolce, Dept Cardiol, Prague, Czech Republic
[3] CardioFocus Inc, Marlborough, MA USA
[4] Icahn Sch Med Mt Sinai, Helmsley Electrophysiol Ctr, One Gustave L Levy Pl,POB 1030, New York, NY 10029 USA
关键词
atrial fibrillation; automated; catheter ablation; endoscopic; laser balloon; POINT-BY-POINT; CATHETER ABLATION; PAROXYSMAL AF; MULTICENTER; BALLOON; TRIAL;
D O I
10.1111/jce.15777
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionVisually-guided laser balloon ablation (VGLA) currently requires careful manual rotation of the laser to create overlapping lesions. A novel semi-automated VGLA may reduce ablation times and lesion gaps. We aimed to compare semi-automated (SA) VGLA to that of manual (MN) VGLA. MethodsAcute: Nine swine underwent right superior pulmonary vein isolation (PVI) using either SA (n = 3, 13-18 W), MN (n = 3, 8.5-12 W), or radiofrequency (RF, n = 3, 25-40 W) and were killed acutely. Chronic: 16 swine, underwent PVI using either SA (n = 8, 15 W) or MN (n = 8, 10 W), and were survived for 1 month before being killed. All hearts were then submitted for pathological evaluation. ResultsAcute: PVI was successful in all 9/9 swine with lesion counts significantly lower in the SA arm (5.3 +/- 5.9, 33.7 +/- 10.0, and 28.0 +/- 4.4 in SA, MN, and RF arms; p = .007 for SA and MN). At necropsy, circumferentiality and transmurality were 98% and 94% in SA, 98% and 80% in MN, and 100% and 100% in RF arms. A single steam pop was noted on sectioning in the SA arm swine and occurred in the high dose (18 W) strategy. Chronic: PVI was acutely successful in 16/16 swine with no difference in PVI durability rates (62.5% vs. 75.0%), lesion transmurality (95.8 +/- 17.4% vs.91.9 +/- 25.9%), and circumferentiality (95.8 +/- 6.6% vs. 94.8 +/- 6.3%) between SA and MN arms. Catheter use time and lesion counts were lower in the SA arm compared to the MN arm (11.5 +/- 12.7 vs. 21.8 +/- 3.8 min, p = .046 and 4.8 +/- 3.83 vs. 35.4 +/- 4.4, p < .001). ConclusionMotor-assisted semi-automated laser balloon ablation can improve upon procedural efficiency by reducing ablation time.
引用
收藏
页码:315 / 324
页数:10
相关论文
共 50 条
  • [21] Semi-automated evaluation tool for retinal vasculopathy
    Benavent, X.
    Martinez-Costa, L.
    Ayala, G.
    Domingo, J.
    Marco, P.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2009, 95 (03) : 288 - 299
  • [22] Evaluation of semi-automated testing in a transfusion service
    Tretter, C
    Johnson, DO
    Crandall, D
    Domkowski, T
    Redmond, W
    Kaeding, C
    TRANSFUSION, 1999, 39 (10) : 138S - 139S
  • [23] Evaluation of a Semi-Automated Workflow for Fragment Growing
    Pirard, Bernard
    Ertl, Peter
    JOURNAL OF CHEMICAL INFORMATION AND MODELING, 2015, 55 (01) : 180 - 193
  • [24] Evaluation of a Semi-Automated Method for Washing Platelets
    Madrid, Fatima
    Tse, Lok
    TRANSFUSION, 2017, 57 : 83A - 83A
  • [25] EVALUATION OF A SEMI-AUTOMATED ENZYME IMMUNOASSAY FOR DIGOXIN
    PRUNSTER, G
    HILDEBRAND, R
    SAMPSON, DC
    HENSLEY, WJ
    PATHOLOGY, 1978, 10 (04) : 398 - 399
  • [26] Semi-automated Analysis of Tricuspid Regurgitation Doppler Profile for Detection and Evaluation of Pulmonary Hypertension
    Dual, Seraina A.
    Amsallem, Myriam
    McElhinney, Doff
    Zamanian, Roham
    Feinstein, Jeffrey
    Haddad, Francois
    Marsden, Alison
    CIRCULATION, 2020, 142
  • [27] Pulmonary vein isolation using radiofrequency ablation
    Iden L.
    Busch S.
    Steven D.
    Tilz R.R.
    Shin D.-I.
    Chun K.J.
    Estner H.
    Bourier F.
    Duncker D.
    Sommer P.
    Metzner A.
    Maurer T.
    Ewertsen N.-C.
    Jansen H.
    Rillig A.
    Johnson V.
    Althoff T.
    Herzschrittmachertherapie + Elektrophysiologie, 2021, 32 (3) : 395 - 405
  • [28] Pulmonary vein isolation with the Pulmonary Vein Ablation Catheter versus conventional point-by-point ablation using the CARTO system: a large, comparative, single-centre study
    De Greef, Y.
    Segers, V. F. M.
    Schwagten, B.
    De Keulenaer, G. W.
    Stockman, D.
    ACTA CARDIOLOGICA, 2011, 66 (05) : 682 - 682
  • [29] SEMI-AUTOMATED ANALYSIS OF RADIOGRAPHS OF LASER FUSION TARGETS
    HENDERSON, TM
    CIELASZY, DE
    SIMMS, RJ
    RENSEL, WB
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1978, 68 (04) : 545 - 545
  • [30] Wide area circumferential ablation for pulmonary vein isolation using radiofrequency versus laser balloon ablation
    Skeete, Jamario
    Sharma, Parikshit S.
    Kenigsberg, David
    Pietrasik, Grzegorz
    Osman, Ahmed F.
    Ravi, Venkatesh
    Du-Fay-de-Lavallaz, Jeanne M.
    Post, Zoe
    Wasserlauf, Jeremiah
    Larsen, Timothy R.
    Krishnan, Kousik
    Trohman, Richard
    Huang, Henry D.
    JOURNAL OF ARRHYTHMIA, 2022, 38 (03) : 336 - 345