Shaking table test of a 10-story self-centering tube building

被引:7
|
作者
Song, Zhaoyang [1 ]
Zhou, Ying [1 ]
Lu, Yiqiu [1 ]
机构
[1] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, 1239 Siping Rd, Shanghai 200092, Peoples R China
来源
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS | 2023年 / 52卷 / 05期
基金
中国国家自然科学基金;
关键词
post-tensioned wall; precast concrete; resilience; rocking system; seismic performance; self-centering tube; shaking table test; slotted connection; very rare ground motion; PRECAST CONCRETE WALL; SEISMIC PERFORMANCE; BEHAVIOR; ROCKING; SYSTEMS; DESIGN; FRAMES; BARS;
D O I
10.1002/eqe.3827
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The severe damage of conventionally designed buildings and consequent socioeconomic impacts after major seismic events have spurred the development of self-centering systems with high seismic resilience. Post-tensioned (PT) walls with rocking interfaces allowed to open and close and unbonded PT bars that provide most of the re-centering ability have been developed extensively as a promising self-centering technology. Aiming at providing essential insights into the seismic performance of self-centering tube systems, a 1/6-scale ten-story self-centering tube building was designed, constructed, and tested on a shaking table subjected to a series of unidirectional and bidirectional ground motions with increasing intensities. The test building consisted of a self-centering tube that included four PT walls and provided the primary lateral force resistance in both directions, a perimeter rocking frame that was designed mainly to carry gravity loads, and particular connections with slots to accommodate the potential displacement incompatibility among the PT walls and surrounding components. The experimental results indicated the excellent seismic performance of the test building that had reliable structural integrity and experienced only confined damage even when subjected to extremely high intensities. The building also exhibited satisfactory re-centering ability with minimal residual deformations at the conclusion of testing. It was demonstrated that the self-centering tube system is a desirable low-damage alternative to traditional tube systems in earthquake-prone regions. The benchmark data from this test provided unique suggestions and support for further research on the design methods, numerical modeling, and experimental testing of self-centering tube systems.
引用
收藏
页码:1511 / 1535
页数:25
相关论文
共 50 条
  • [41] Life-cycle benefits estimation of self-centering building structures
    Hu, Shuling
    Wang, Wei
    Alam, M. Shahria
    Ke, Ke
    ENGINEERING STRUCTURES, 2023, 284
  • [42] Seismic Assessment of Self-Centering Rocking Braced Systems with Story Energy Dissipation
    Raeiszadeh, Farzad
    Mansoori, Mohammad Reza
    Moghadam, Abdolreza S.
    Aziminejad, Armin
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2024,
  • [43] Shaking table test on stagger transfer structure in tall building
    Wu, Bo
    Shen, Chao-Yong
    Zhou, Fu-Lin
    Huang, Xiang-Yun
    Chen, Jian-Qiu
    Luo, Xue-Hai
    Advances in Structural Engineering:Theory and Applications Vols 1 and 2, 2006, : 1383 - 1390
  • [44] Structural response prediction of the 2015 E-defense 10-story RC building test using pushover analysis
    Tsung-Chih Chiou
    Lap-Loi Chung
    Yu-Chih Lai
    Yi-Han Chao
    Juin-Fu Chai
    Shyh-Jiann Hwang
    Jae-Do Kang
    Koichi Kajiwara
    Bulletin of Earthquake Engineering, 2023, 21 : 6723 - 6744
  • [45] Shaking table test of wooden building models for structural identification
    Altunisik, Ahmet C.
    EARTHQUAKES AND STRUCTURES, 2017, 12 (01) : 67 - 77
  • [46] Shake-Table Tests and Numerical Analysis of Self-Centering Prestressed Concrete Frame
    Guo, Tong
    Hao, Yaowen
    Song, Lianglong
    Cao, Zhiliang
    ACI STRUCTURAL JOURNAL, 2019, 116 (03) : 3 - 17
  • [47] Nonlinear structural system identification using shaking table test data of five-story model building
    Ogiyama, K
    Sato, T
    HEALTH MONITORING AND SMART NONDESTRUCTIVE EVALUATION OF STRUCTURAL AND BIOLOGICAL SYSTEM III, 2004, 5394 : 475 - 484
  • [48] Effects of Prediction Error Bias on Model Calibration and Response Prediction of a 10-Story Building
    Behmanesh, Iman
    Yousefianmoghadam, Seyedsina
    Nozari, Amin
    Moaveni, Babak
    Stavridis, Andreas
    MODEL VALIDATION AND UNCERTAINTY QUANTIFICATION, VOL 3, 2016, : 279 - 291
  • [49] Shaking table test study on mid-story isolation structures
    Jin, Jianmin
    Tan, Ping
    Zhou, Fulin
    Ma, Yuhong
    Shen, Chaoyong
    TRENDS IN CIVIL ENGINEERING, PTS 1-4, 2012, 446-449 : 378 - 381
  • [50] Development of a high-performance hybrid self-centering building for seismic resilience
    Shams, Amir Sina
    Ghobadi, Mohammad Soheil
    ENGINEERING STRUCTURES, 2021, 226