Shaking table test of a 10-story self-centering tube building

被引:7
|
作者
Song, Zhaoyang [1 ]
Zhou, Ying [1 ]
Lu, Yiqiu [1 ]
机构
[1] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, 1239 Siping Rd, Shanghai 200092, Peoples R China
来源
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS | 2023年 / 52卷 / 05期
基金
中国国家自然科学基金;
关键词
post-tensioned wall; precast concrete; resilience; rocking system; seismic performance; self-centering tube; shaking table test; slotted connection; very rare ground motion; PRECAST CONCRETE WALL; SEISMIC PERFORMANCE; BEHAVIOR; ROCKING; SYSTEMS; DESIGN; FRAMES; BARS;
D O I
10.1002/eqe.3827
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The severe damage of conventionally designed buildings and consequent socioeconomic impacts after major seismic events have spurred the development of self-centering systems with high seismic resilience. Post-tensioned (PT) walls with rocking interfaces allowed to open and close and unbonded PT bars that provide most of the re-centering ability have been developed extensively as a promising self-centering technology. Aiming at providing essential insights into the seismic performance of self-centering tube systems, a 1/6-scale ten-story self-centering tube building was designed, constructed, and tested on a shaking table subjected to a series of unidirectional and bidirectional ground motions with increasing intensities. The test building consisted of a self-centering tube that included four PT walls and provided the primary lateral force resistance in both directions, a perimeter rocking frame that was designed mainly to carry gravity loads, and particular connections with slots to accommodate the potential displacement incompatibility among the PT walls and surrounding components. The experimental results indicated the excellent seismic performance of the test building that had reliable structural integrity and experienced only confined damage even when subjected to extremely high intensities. The building also exhibited satisfactory re-centering ability with minimal residual deformations at the conclusion of testing. It was demonstrated that the self-centering tube system is a desirable low-damage alternative to traditional tube systems in earthquake-prone regions. The benchmark data from this test provided unique suggestions and support for further research on the design methods, numerical modeling, and experimental testing of self-centering tube systems.
引用
收藏
页码:1511 / 1535
页数:25
相关论文
共 50 条
  • [21] Simulation of the shaking table test of a seven-story shear wall building
    Martinelli, Paolo
    Filippou, Filip C.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2009, 38 (05): : 587 - 607
  • [22] Shake table test and numerical study of self-centering steel frame with SMA braces
    Qiu, Canxing
    Zhu, Songye
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2017, 46 (01): : 117 - 137
  • [23] Shaking table investigation of pulse-type seismic behavior of a self-centering reinforced concrete frame structure
    Zhang, Hongmei
    Fang, Yi
    Cao, Lening
    Hu, Fan
    Duan, Yuanfeng
    ENGINEERING STRUCTURES, 2025, 325
  • [24] Experimental investigation of tri-axial self-centering reinforced concrete frame structures through shaking table tests
    Cui, Ye
    Lu, Xilin
    Jiang, Chun
    ENGINEERING STRUCTURES, 2017, 132 : 684 - 694
  • [25] Seismic Performance of Steel Frame Structures with Novel Self-Centering Beams: Shaking-Table Tests and Numerical Analysis
    Xu, Gang
    Guo, Tong
    Li, Ai-qun
    Zhou, Tong
    Shuang, Chao
    JOURNAL OF STRUCTURAL ENGINEERING, 2025, 151 (03)
  • [26] Shake-Table Testing of a Full-Scale 10-Story Resilient Mass Timber Building
    Pei, Shiling
    Ryan, Keri L.
    Berman, Jeffrey W.
    van de Lindt, John W.
    Pryor, Steve
    Huang, Da
    Wichman, Sarah
    Busch, Aleesha
    Roser, William
    Wynn, Sir Lathan
    Ji, Yi-en
    Hutchinson, Tara
    Sorosh, Shokrullah
    Zimmerman, Reid B.
    Dolan, James
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (12)
  • [27] Windstorm Resilience of a 10-Story Steel Frame Office Building
    Judd, Johnn P.
    ASCE-ASME JOURNAL OF RISK AND UNCERTAINTY IN ENGINEERING SYSTEMS PART A-CIVIL ENGINEERING, 2018, 4 (03):
  • [28] Seismic response analysis of RC frame core-tube building with self-centering braces
    Xu, Long-He
    Xiao, Shui-Jing
    Lu, Xiao
    STRUCTURAL MONITORING AND MAINTENANCE, 2018, 5 (02): : 189 - 204
  • [29] Collapse behavior of 6 story wall frame building during shaking table test
    Sugimoto K.
    Katsumata H.
    Masuda Y.
    Yonezawa K.
    Nishimura K.
    Miura K.
    Nishiyama M.
    Matsumori T.
    Kagamihata T.
    Tasai A.
    Journal of Structural and Construction Engineering, 2017, 82 (741): : 1759 - 1768
  • [30] Shake-table testing of 2-story steel framed building with self-centering modular panels and slit steel plate walls
    Chu, Gongling
    Wang, Wei
    Zhang, Yunfeng
    ENGINEERING STRUCTURES, 2021, 247