Shaking table test of a 10-story self-centering tube building

被引:7
|
作者
Song, Zhaoyang [1 ]
Zhou, Ying [1 ]
Lu, Yiqiu [1 ]
机构
[1] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, 1239 Siping Rd, Shanghai 200092, Peoples R China
来源
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS | 2023年 / 52卷 / 05期
基金
中国国家自然科学基金;
关键词
post-tensioned wall; precast concrete; resilience; rocking system; seismic performance; self-centering tube; shaking table test; slotted connection; very rare ground motion; PRECAST CONCRETE WALL; SEISMIC PERFORMANCE; BEHAVIOR; ROCKING; SYSTEMS; DESIGN; FRAMES; BARS;
D O I
10.1002/eqe.3827
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The severe damage of conventionally designed buildings and consequent socioeconomic impacts after major seismic events have spurred the development of self-centering systems with high seismic resilience. Post-tensioned (PT) walls with rocking interfaces allowed to open and close and unbonded PT bars that provide most of the re-centering ability have been developed extensively as a promising self-centering technology. Aiming at providing essential insights into the seismic performance of self-centering tube systems, a 1/6-scale ten-story self-centering tube building was designed, constructed, and tested on a shaking table subjected to a series of unidirectional and bidirectional ground motions with increasing intensities. The test building consisted of a self-centering tube that included four PT walls and provided the primary lateral force resistance in both directions, a perimeter rocking frame that was designed mainly to carry gravity loads, and particular connections with slots to accommodate the potential displacement incompatibility among the PT walls and surrounding components. The experimental results indicated the excellent seismic performance of the test building that had reliable structural integrity and experienced only confined damage even when subjected to extremely high intensities. The building also exhibited satisfactory re-centering ability with minimal residual deformations at the conclusion of testing. It was demonstrated that the self-centering tube system is a desirable low-damage alternative to traditional tube systems in earthquake-prone regions. The benchmark data from this test provided unique suggestions and support for further research on the design methods, numerical modeling, and experimental testing of self-centering tube systems.
引用
收藏
页码:1511 / 1535
页数:25
相关论文
共 50 条
  • [31] Development and test of a self-centering fluidic viscous damper
    Zhu, Ruizhao
    Guo, Tong
    Mwangilwa, Frank
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (13) : 2835 - 2849
  • [32] SEISMIC SAFETY - 10-STORY UBC DESIGNED STEEL BUILDING
    LAI, SSP
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 1983, 109 (02): : 557 - 575
  • [33] A novel inerter-enhanced self-centering damper (ISCD) for improving seismic resilience of self-centering RC building frames
    Kong, Sihua
    Zhao, Guifeng
    Ma, Yuhong
    Dong, You
    Feng, Ruiwei
    Yang, Zhenyu
    ENGINEERING STRUCTURES, 2025, 330
  • [34] Seismic performance and damage analysis of RC frame-core tube building with self-centering braces
    Xiao, Shuijing
    Xu, Longhe
    Li, Zhongxian
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2019, 120 : 146 - 157
  • [35] Review on self-centering damper for seismic resilient building structures
    Xu, Gang
    Guo, Tong
    Li, Aiqun
    Wang, Shiyuan
    Zhang, Ruijun
    Zhu, Ruizhao
    Xu, Jun
    STRUCTURES, 2023, 54 : 58 - 77
  • [36] Substructure-plus of 10-story building assembled in 48 hours
    Relph, M.K., 2012, McGraw-Hill Companies (269):
  • [37] Shaking table model test of Beijing LG Building
    State Key Laboratory for Disaster Reduction in Civil Engineering, Tongji University, Shanghai 200092, China
    不详
    Jianzhu Jiegou Xuebao, 2006, 2 (10-14+39):
  • [38] Hierarchical Bayesian Calibration and Response Prediction of a 10-Story Building Model
    Song, Mingming
    Behmanesh, Iman
    Moaveni, Babak
    Papadimitriou, Costas
    MODEL VALIDATION AND UNCERTAINTY QUANTIFICATION, VOL 3, 2019, : 153 - 165
  • [39] Research on Shaking Table Test of Base and Story Isolation Structures
    Zheng, Guochen
    Xu, Hangli
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING IV, 2014, 580-583 : 1776 - +
  • [40] Shaking table test and numerical analyses of a multi-story traditional tower-style building
    Ling, Huaiquan
    Xue, Jianyang
    Qi, Liangjie
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2024, 53 (10): : 3184 - 3204