Shaking table test of a 10-story self-centering tube building

被引:7
|
作者
Song, Zhaoyang [1 ]
Zhou, Ying [1 ]
Lu, Yiqiu [1 ]
机构
[1] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, 1239 Siping Rd, Shanghai 200092, Peoples R China
来源
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS | 2023年 / 52卷 / 05期
基金
中国国家自然科学基金;
关键词
post-tensioned wall; precast concrete; resilience; rocking system; seismic performance; self-centering tube; shaking table test; slotted connection; very rare ground motion; PRECAST CONCRETE WALL; SEISMIC PERFORMANCE; BEHAVIOR; ROCKING; SYSTEMS; DESIGN; FRAMES; BARS;
D O I
10.1002/eqe.3827
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The severe damage of conventionally designed buildings and consequent socioeconomic impacts after major seismic events have spurred the development of self-centering systems with high seismic resilience. Post-tensioned (PT) walls with rocking interfaces allowed to open and close and unbonded PT bars that provide most of the re-centering ability have been developed extensively as a promising self-centering technology. Aiming at providing essential insights into the seismic performance of self-centering tube systems, a 1/6-scale ten-story self-centering tube building was designed, constructed, and tested on a shaking table subjected to a series of unidirectional and bidirectional ground motions with increasing intensities. The test building consisted of a self-centering tube that included four PT walls and provided the primary lateral force resistance in both directions, a perimeter rocking frame that was designed mainly to carry gravity loads, and particular connections with slots to accommodate the potential displacement incompatibility among the PT walls and surrounding components. The experimental results indicated the excellent seismic performance of the test building that had reliable structural integrity and experienced only confined damage even when subjected to extremely high intensities. The building also exhibited satisfactory re-centering ability with minimal residual deformations at the conclusion of testing. It was demonstrated that the self-centering tube system is a desirable low-damage alternative to traditional tube systems in earthquake-prone regions. The benchmark data from this test provided unique suggestions and support for further research on the design methods, numerical modeling, and experimental testing of self-centering tube systems.
引用
收藏
页码:1511 / 1535
页数:25
相关论文
共 50 条
  • [1] Seismic design and engineering practice of a 10-story self-centering precast concrete wall structure
    Zhou, Ying
    Zhu, Xiaoying
    Wu, Hao
    Gu, Anqi
    Tian, Wenbo
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2023, 32 (13):
  • [2] Shaking table test for externally-hung self-centering rocking wall structure
    Li, Xiangmin
    Zhang, Fuwen
    Tian, Kun
    Wang, Zhuolin
    Jiang, Lu
    Dong, Jinzhi
    BULLETIN OF EARTHQUAKE ENGINEERING, 2021, 19 (02) : 863 - 887
  • [3] Shaking table test for externally-hung self-centering rocking wall structure
    Xiangmin Li
    Fuwen Zhang
    Kun Tian
    Zhuolin Wang
    Lu Jiang
    Jinzhi Dong
    Bulletin of Earthquake Engineering, 2021, 19 : 863 - 887
  • [4] Shaking table tests of a self-centering designed bridge substructure
    Cheng, Chin-Tung
    ENGINEERING STRUCTURES, 2008, 30 (12) : 3426 - 3433
  • [5] Shaking table test of RC frame structure with energy dissipating self-centering hinge joint
    Lu L.
    Yan H.
    Xia W.
    Tan Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 : 53 - 60
  • [6] Shaking table test and numerical simulation of a 1/2-scale self-centering reinforced concrete frame
    Lu, Xilin
    Cui, Ye
    Liu, Jingjing
    Gao, Wenjun
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2015, 44 (12): : 1899 - 1917
  • [7] Seismic performance of bridge with unbonded posttensioned self-centering segmented concrete-filled steel-tube columns: An underwater shaking table test
    Zhang, Dan
    Li, Ning
    Li, Zhong-Xian
    Xie, Lili
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2020, 138 (138)
  • [8] Full-scale shaking table experiments on the seismic response of a 10-story reinforced-concrete building: overview and analysis
    Jae-Do Kang
    Koichi Kajiwara
    Takuya Nagae
    Eiji Sato
    Yusuke Tosauchi
    Bulletin of Earthquake Engineering, 2023, 21 : 6511 - 6534
  • [9] Shaking table test of the seismic performance for railway simply-supported girder bridge isolated by self-centering bearing
    Wei, Biao
    Tan, Hao
    Jiang, Lizhong
    Xiao, Binqi
    Lu, Andong
    ENGINEERING STRUCTURES, 2024, 300
  • [10] Full-scale shaking table experiments on the seismic response of a 10-story reinforced-concrete building: overview and analysis
    Kang, Jae-Do
    Kajiwara, Koichi
    Nagae, Takuya
    Sato, Eiji
    Tosauchi, Yusuke
    BULLETIN OF EARTHQUAKE ENGINEERING, 2023, 21 (15) : 6511 - 6534