Accuracy of Intraocular Lens Power Calculation Based on Total Keratometry in Patients With Flat and Steep Corneas

被引:8
|
作者
Qin, Y. I. N. G. Y. A. N. [1 ,2 ]
Liu, L. I. A. N. G. P. I. N. G. [1 ,2 ]
Mao, Y. A. N. [1 ,2 ]
Ding, Y. U. J. I. E. [1 ,2 ]
Ye, S. H. A. O. B., I [1 ,2 ]
Sun, A. O. [1 ,2 ]
Wu, M. I. N. G. X. I. N. G. [1 ,2 ,3 ]
机构
[1] Sun Yat sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangdong Prov Key Lab Ophthalmol & Visual Sci, Guangzhou, Peoples R China
[2] Guangdong Prov Clin Res Ctr Ocular Dis, Guangzhou, Peoples R China
[3] Sun Yat sen Univ, Zhongshan Ophthalm Ctr, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
ASTIGMATISM;
D O I
10.1016/j.ajo.2022.11.011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: To analyze the accuracy of the current in-traocular lens power calculation formulas using standard keratometry (K) and total keratometry (TK) data in pa-tients with fiat and steep corneas. center dot DESIGN: Retrospective consecutive cross-sectional study. center dot METHODS: An optical biometer with swept-source op-tical coherence tomography was used in this retrospective study. The standard deviation (SD), mean absolute error (MAE), median absolute error (MedAE), and the pro-portion of eyes with prediction error (PE) within +/- 0.25 diopter (D), +/- 0.5 D, +/- 0.75 D, and +/- 1.00 D were calcu-lated to evaluate the refractive outcomes of each formula. center dot RESULTS: A total of 231 eyes from 231 patients were included. In the entire study cohort, the Emmetropia Verifying Optical (EVO) formula using TK data showed the lowest SD (0.383) and MAE (0.30) and the highest percentage of cases with a PE within +/- 0.5 D (81.4%). In the fiat keratometry group, the EVO ( P = .042), Haigis ( P = .043), Hoffer Q ( P = .038) and Holladay 1 ( P = .013) formulas using TK data had significantly lower SD than using K data. The EVO formula using TK data showed the lowest SD (0.357) and MAE (0.28). In the steep keratometry group, the Hoffer Q ( P = .036) and SRK/T ( P = .029) formulas using TK data had sig-nificantly lower SD than using K data. The BUII TK formula showed the lowest SD (0.431), MedAE (0.26), and MAE (0.32). center dot CONCLUSION: The TK data set showed a better trend of refractive outcomes, especially in the fiat and steep ker-atometry groups. EVO (TK) and BUII TK formulas were suggested for eyes with K values lower than 42 D and K values higher than 46 D, respectively. (Am J Ophthal-mol 2023;247: 103-110. (c) 2022 Elsevier Inc. All rights reserved.)
引用
收藏
页码:103 / 110
页数:8
相关论文
共 50 条
  • [41] Accuracy of intraocular lens power calculation in patients with endothelial dystrophy without edema
    Shemer, Asaf
    Fradkin, Maayan
    Dubinsky-Pertzov, Biana
    Reitblat, Olga
    Simaan, Francis
    Sella, Ruti
    Pras, Eran
    Einan-Lifshitz, Adi
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2025, 51 (02): : 141 - 146
  • [42] Accuracy of a new intraocular lens power calculation method based on artificial intelligence
    Carmona Gonzalez, David
    Palomino Bautista, Carlos
    EYE, 2021, 35 (02) : 517 - 522
  • [43] Accuracy of a new intraocular lens power calculation method based on artificial intelligence
    David Carmona González
    Carlos Palomino Bautista
    Eye, 2021, 35 : 517 - 522
  • [44] Total keratometry in intraocular lens power calculations in eyes with previous laser refractive surgery
    Lawless, Michael
    Jiang, James Y.
    Hodge, Chris
    Sutton, Gerard
    Roberts, Timothy, V
    Barrett, Graham
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 48 (06): : 749 - 756
  • [45] Accuracy of Scheimpflug corneal power measurements for intraocular lens power calculation
    Savini, Giacomo
    Barboni, Piero
    Carbonelli, Michele
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (07): : 1193 - 1197
  • [46] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Jingyi Shi
    Zehui Zhu
    Bin Hu
    Shuyi Qian
    Yalan Wang
    Pingjun Chang
    Yun-e Zhao
    Ophthalmology and Therapy, 2024, 13 : 1321 - 1342
  • [47] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Shi, Jingyi
    Zhu, Zehui
    Hu, Bin
    Qian, Shuyi
    Wang, Yalan
    Chang, Pingjun
    Zhao, Yun-e
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (05) : 1321 - 1342
  • [48] CLINICAL VARIABILITY IN KERATOMETRY, ULTRASOUND BIOMETRY MEASUREMENTS, AND EMMETROPIC INTRAOCULAR-LENS POWER CALCULATION
    PIERRO, L
    MODORATI, G
    BRANCATO, R
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (01): : 91 - 94
  • [49] Intraocular lens power calculation in phacovitrectomy patients
    Partwardhan, Ashish A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (04): : 529 - 529
  • [50] Evaluation of the Accuracy of Intraocular Lens Power Calculation Formulas in Phacovitrectomy
    Tanaka, Yuichiro
    Kamiya, Kazutaka
    Igarahi, Akihito
    Shoji, Nobuyuki
    Tsuchiya, Hiroshi
    Takahashi, Shinya
    Ishikawa, Eri
    Kozawa, Tadahiko
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (08) : 2197 - 2208