Accuracy of Intraocular Lens Power Calculation Based on Total Keratometry in Patients With Flat and Steep Corneas

被引:8
|
作者
Qin, Y. I. N. G. Y. A. N. [1 ,2 ]
Liu, L. I. A. N. G. P. I. N. G. [1 ,2 ]
Mao, Y. A. N. [1 ,2 ]
Ding, Y. U. J. I. E. [1 ,2 ]
Ye, S. H. A. O. B., I [1 ,2 ]
Sun, A. O. [1 ,2 ]
Wu, M. I. N. G. X. I. N. G. [1 ,2 ,3 ]
机构
[1] Sun Yat sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangdong Prov Key Lab Ophthalmol & Visual Sci, Guangzhou, Peoples R China
[2] Guangdong Prov Clin Res Ctr Ocular Dis, Guangzhou, Peoples R China
[3] Sun Yat sen Univ, Zhongshan Ophthalm Ctr, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
ASTIGMATISM;
D O I
10.1016/j.ajo.2022.11.011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: To analyze the accuracy of the current in-traocular lens power calculation formulas using standard keratometry (K) and total keratometry (TK) data in pa-tients with fiat and steep corneas. center dot DESIGN: Retrospective consecutive cross-sectional study. center dot METHODS: An optical biometer with swept-source op-tical coherence tomography was used in this retrospective study. The standard deviation (SD), mean absolute error (MAE), median absolute error (MedAE), and the pro-portion of eyes with prediction error (PE) within +/- 0.25 diopter (D), +/- 0.5 D, +/- 0.75 D, and +/- 1.00 D were calcu-lated to evaluate the refractive outcomes of each formula. center dot RESULTS: A total of 231 eyes from 231 patients were included. In the entire study cohort, the Emmetropia Verifying Optical (EVO) formula using TK data showed the lowest SD (0.383) and MAE (0.30) and the highest percentage of cases with a PE within +/- 0.5 D (81.4%). In the fiat keratometry group, the EVO ( P = .042), Haigis ( P = .043), Hoffer Q ( P = .038) and Holladay 1 ( P = .013) formulas using TK data had significantly lower SD than using K data. The EVO formula using TK data showed the lowest SD (0.357) and MAE (0.28). In the steep keratometry group, the Hoffer Q ( P = .036) and SRK/T ( P = .029) formulas using TK data had sig-nificantly lower SD than using K data. The BUII TK formula showed the lowest SD (0.431), MedAE (0.26), and MAE (0.32). center dot CONCLUSION: The TK data set showed a better trend of refractive outcomes, especially in the fiat and steep ker-atometry groups. EVO (TK) and BUII TK formulas were suggested for eyes with K values lower than 42 D and K values higher than 46 D, respectively. (Am J Ophthal-mol 2023;247: 103-110. (c) 2022 Elsevier Inc. All rights reserved.)
引用
收藏
页码:103 / 110
页数:8
相关论文
共 50 条
  • [21] Accuracy of IOL power calculation using total keratometry versus regular keratometry
    Reus, N. J.
    ACTA OPHTHALMOLOGICA, 2020, 98 : 31 - 31
  • [22] Scheimpflug photography keratometry readings for routine intraocular lens power calculation
    Shammas, H. John
    Hoffer, Kenneth J.
    Shammas, Maya C.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (02): : 330 - 334
  • [23] An evaluation of the accuracy of toric intraocular lens power calculation based on measured total corneal refractive power
    Yang, Zhi
    Zhou, Yanwen
    Jin, Tianru
    Li, Jingjing
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (02) : 541 - 546
  • [24] Prediction accuracy of IOL power calculation in patients with a large difference between conventional keratometry and total keratometry
    Hyon, Joon-Young
    Son, Yengwoo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [25] Intraocular Lens Power Calculation According to the Difference between Anterior and Total Keratometry Using Scheimpflug Imaging
    Kim, Joong Hee
    Cho, Kyong Jin
    Chung, Ho Seok
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2021, 62 (09): : 1181 - 1188
  • [26] Accuracy of toric intraocular lens power calculation depending on different keratometry values using a novel network based software platform
    Ramsauer, Michaela
    Luft, Nikolaus
    Vounotrypidis, Efstathios
    Priglinger, Siegfried G.
    Mayer, Wolfgang J.
    FRONTIERS IN MEDICINE, 2024, 11
  • [27] Accuracy of Traditional and Modern Formulas for Intraocular Lens Power Calculation After Radial Keratotomy Using Standard Keratometry
    Helaly, Hany Ahmed
    Elhady, Amr Mohamed
    Elnaggar, Osama Ramadan
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 2589 - 2597
  • [28] Intraocular Lens Power Calculations in Keratoconus Eyes Comparing Keratometry, Total Keratometry, and Newer Formulae
    Heath, Michael T.
    Mulpuri, Lakshman
    Kimiagarov, Eden
    Patel, Raj P.
    Murphy, David A.
    Levine, Harry
    Tonk, Rahul S.
    Cooke, David L.
    Riaz, Kamran M.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 253 : 206 - 214
  • [29] Biometry, keratometry, and calculation of intraocular lens power for the bald eagle (Haliaeetus leucocephalus)
    Kuhn, Sonia E.
    Hendrix, Diane V. H.
    Jones, Michael P.
    Ward, Daniel A.
    Baine, Katherine H.
    Franklin, Stephen R.
    VETERINARY OPHTHALMOLOGY, 2015, 18 : 106 - 112
  • [30] Comparison of keratometry and total corneal power, as measured by an SS-OCT-based optical biometer, for intraocular lens power calculation in Asian eyes
    Savini, Giacomo
    Taroni, Leonardo
    Jeon, Sohee
    Koh, Kyungmin
    Yang, Hyun Seung
    Abulafia, Adi
    Lupardi, Enrico
    Hoffer, Kenneth J.
    Moramarco, Antonio
    Schiano-Lomoriello, Domenico
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (11): : 1117 - 1122