Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation

被引:3
|
作者
Shi, Jingyi [1 ,2 ,3 ,4 ]
Zhu, Zehui [1 ,2 ,3 ,4 ]
Hu, Bin [1 ,2 ,3 ,4 ,5 ]
Qian, Shuyi [1 ,2 ,3 ,4 ,6 ]
Wang, Yalan [1 ,2 ,3 ,4 ]
Chang, Pingjun [1 ,2 ,3 ,4 ]
Zhao, Yun-e [1 ,2 ,3 ,4 ]
机构
[1] Wenzhou Med Univ, Eye Hosp, Wenzhou 325000, Zhejiang, Peoples R China
[2] Wenzhou Med Univ, Sch Ophthalmol & Optometry, Wenzhou 325000, Zhejiang, Peoples R China
[3] Natl Clin Res Ctr Ocular Dis, Wenzhou 325000, Zhejiang, Peoples R China
[4] Wenzhou Med Univ, Eye Hosp, Hangzhou Branch, 618 Fengqi Rd, Hangzhou 310000, Zhejiang, Peoples R China
[5] Shaoxing Peoples Hosp, Shaoxing 312000, Zhejiang, Peoples R China
[6] Ningbo Univ, Affiliated Hosp 1, Ningbo 315010, Zhejiang, Peoples R China
关键词
Toric intraocular lens; Cataract; Power calculation formulas; Sphere equivalent; HOFFER-Q; EYES;
D O I
10.1007/s40123-024-00926-x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
IntroductionThe aim of this work is to evaluate the accuracy of the Barrett Universal II (BU II), Emmetropia verifying optical (EVO) 2.0, Haigis, Hoffer Q, Hoffer QST (Savini/Taroni) (HQST), Holladay 1, Kane, Ladas Super, Sanders-Retzlaff-Kraff/theoretical (SRK/T), and T2 intraocular lens (IOL) power formulas for calculating spherical equivalent (SE) of toric IOL.MethodsThis study enrolled consecutive patients who underwent phacoemulsification and toric IOL implantation at the Eye Hospital of Wenzhou Medical University in Hangzhou from 2015 to 2022. We compared the new-generation formulas with Gaussian optics-based standard formulas, and calculated the mean absolute error (MAE), median absolute error (MedAE), and percentage of eyes within +/- 0.25 diopter (D), +/- 0.50 D, +/- 0.75 D and +/- 1.00 D of the target refraction. Subgroup analyses were conducted based on the anterior chamber depth (ACD), keratometry (K), and toricity (T).ResultsA total of 207 eyes of 207 patients were included in this study. Overall, the Kane and EVO2.0 formulas demonstrated the lowest MedAEs. The EVO2.0 formula exhibited the highest percentage of eyes within +/- 0.50 D, +/- 0.75 D, +/- 1.00 D. Moreover, the EVO2.0 formula showed the lowest MedAE for flat K subgroup, the highest percentage of eyes within +/- 0.50 D, +/- 1.00 D for shallow ACD subgroup, the highest percentage of eyes within +/- 0.75 D for regular ACD, flat K, T2-T3, T4-T5 subgroups. The Kane and formula performed the lowest MedAE in the T4-T5 subgroup.ConclusionsApplication of the Kane and EVO2.0 formulas significantly improved the prediction of postoperative SE outcome for toric IOL compared to the other formulas.
引用
收藏
页码:1321 / 1342
页数:22
相关论文
共 50 条
  • [1] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Jingyi Shi
    Zehui Zhu
    Bin Hu
    Shuyi Qian
    Yalan Wang
    Pingjun Chang
    Yun-e Zhao
    Ophthalmology and Therapy, 2024, 13 : 1321 - 1342
  • [2] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Zhao, Jing
    Liu, Liang-Ping
    Cheng, Huan-Huan
    Li, Jian-Bing
    Han, Xiao-Tong
    Liu, Yu
    Wu, Ming-Xing
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (09) : 1378 - 1384
  • [3] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Jing Zhao
    Liang-Ping Liu
    Huan-Huan Cheng
    Jian-Bing Li
    Xiao-Tong Han
    Yu Liu
    Ming-Xing Wu
    International Journal of Ophthalmology, 2020, (09) : 1378 - 1384
  • [4] Accuracy of Intraocular Lens Calculation Formulas
    Melles, Ronald B.
    Holladay, Jack T.
    Chang, William J.
    OPHTHALMOLOGY, 2018, 125 (02) : 169 - 178
  • [5] Intraocular lens power calculation formula accuracy: Comparison of 12 formulas for a trifocal hydrophilic intraocular lens
    Rocha-de-Lossada, Carlos
    Colmenero-Reina, Elvira
    Flikier, David
    Castro-Alonso, Francisco-Javier
    Rodriguez-Raton, Alvaro
    Garcia-Madrona, Jose-Luis
    Peraza-Nieves, Jorge
    Sanchez-Gonzalez, Jose-Maria
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (06) : 2981 - 2988
  • [6] Accuracy of New Intraocular Lens Power Calculation Formulas: A Lens Thickness Study
    Taroni, Leonardo
    Hoffer, Kenneth J.
    Lupardi, Enrico
    Barboni, Piero
    Savini, Giacomo
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (03) : 202 - 206
  • [7] Evaluation of the Accuracy of Intraocular Lens Power Calculation Formulas in Phacovitrectomy
    Tanaka, Yuichiro
    Kamiya, Kazutaka
    Igarahi, Akihito
    Shoji, Nobuyuki
    Tsuchiya, Hiroshi
    Takahashi, Shinya
    Ishikawa, Eri
    Kozawa, Tadahiko
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (08) : 2197 - 2208
  • [8] Comparison of the accuracy of 11 intraocular lens power calculation formulas
    Carmona-Gonzalez, David
    Castillo-Gomez, Alfredo
    Palomino-Bautista, Carlos
    Romero-Dominguez, Marta
    Gutierrez-Moreno, Maria Angeles
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (05) : 2370 - 2376
  • [9] A Comparison of the Accuracy of 6 Modern Toric Intraocular Lens Formulas
    Kane, Jack X.
    Connell, Benjamin
    OPHTHALMOLOGY, 2020, 127 (11) : 1472 - 1486
  • [10] Comparative Accuracy Of Five Modern Toric Intraocular Lens Formulas
    Yang, Soonwon
    Han, Hyoji
    Lee, Hyun soo
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2025, 274 : 1 - 8