Patient skin dose measurement and risk of deterministic effect during fluoroscopy cardiac procedures

被引:1
|
作者
Nana, Ruth Njantang [1 ,2 ]
Inkoom, Stephen [3 ,4 ]
Moyo, Maurice Ndontchueng [1 ,2 ]
Mvoufo, Fokou [1 ,2 ]
Hasford, Francis [3 ,5 ]
Owusu-Manteaw, Philip [4 ]
Motapon, Ousmanou [1 ,6 ]
机构
[1] Univ Douala, Postgrad Sch Fundamental & Appl Sci, Fundamental Phys Lab, POB 24157, Douala, Cameroon
[2] Natl Radiat Protect Agcy NRPA, POB 5331, Akwa, Douala, Cameroon
[3] Univ Ghana, Sch Nucl & Allied Sci, POB AE 1, Accra, Ghana
[4] Ghana Atom Energy Commiss, Radat Protect Inst, POB LG80, Legon, Accra, Ghana
[5] Ghana Atom Energy Commiss, Radiol & Med Sci Res Inst, POB LG80, Legon, Accra, Ghana
[6] Univ Maroua, Fac Sci, POB 814, Maroua, Cameroon
关键词
BACKSCATTER FACTORS;
D O I
10.1093/rpd/ncad206
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study aimed at assessing patient's peak skin doses (PSD) during fluoroscopy cardiac procedures and proposed a look up table to enhance patient's dose management. Perspex phantom and thermoluminescent dosemeters (TLD) were irradiated for different dose levels with X-ray equipment (Philips Azurion 7). It was found that PSD measures were higher than the kerma at the interventional reference point [K (IRP)] reported with factors 1.55, 1.75 and 2.88 for anterior posterior (AP0(o)), left anterior oblique (LAO45(o)) and right anterior oblique (RAO45(o)), respectively. The equations describing the correlation between the PSD measured kerma area product and cumulative air kerma were found with R-square values of 0.98 and 0.99, respectively. The statistical analysis shows a strong linear correlation between PSD and K (IRP) (P-value = 0.05). It was also found that 27% of the patients population considered in this work, received a skin dose higher than the threshold of deterministic effect of 2 Gy and a look up table with the equation of fitness were proposed to be implemented in the facility for K (IRP) higher than 500 mGy.
引用
收藏
页码:2053 / 2060
页数:8
相关论文
共 50 条
  • [31] A comparison of patient dose and occupational eye dose to the operator and nursing staff during transcatheter cardiac and endovascular procedures
    Wilson-Stewart, Kelly S.
    Fontanarosa, Davide
    Malacova, Eva
    Trapp, Jamie V.
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [32] A comparison of patient dose and occupational eye dose to the operator and nursing staff during transcatheter cardiac and endovascular procedures
    Kelly S. Wilson-Stewart
    Davide Fontanarosa
    Eva Malacova
    Jamie V. Trapp
    Scientific Reports, 13 (1)
  • [33] Skin dose to patients from interventional radiology and cardiology procedures with potentially long fluoroscopy times
    Mooney, RB
    RADIATION PROTECTION DOSIMETRY, 2000, 90 (1-2) : 123 - 126
  • [34] Management of patient skin dose in fluoroscopically guided interventional procedures
    Wagner, LK
    Archer, BR
    Cohen, AM
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (01) : 25 - 33
  • [35] Radiation Dose in Cardiac Catheterization Procedures: Impact of a Systematic Reduction in Pulsed Fluoroscopy Frame Rate
    Schultz, C.
    Dixon, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3404 - 3404
  • [36] Evaluation of Patient Radiation Dose during Cardiac Interventional Procedures: What Is the Most Effective Method?
    Chida, K.
    Kagaya, Y.
    Saito, H.
    Ishibashi, T.
    Takahashi, S.
    Zuguchi, M.
    ACTA RADIOLOGICA, 2009, 50 (05) : 474 - 481
  • [37] Patient and personnel exposure during CT fluoroscopy-guided interventional procedures
    Nawfel, RD
    Judy, PF
    Silverman, SG
    Hooton, S
    Tuncali, K
    Adams, DF
    RADIOLOGY, 2000, 216 (01) : 180 - 184
  • [38] Reduction of fluoroscopy dose using an ArtisQ. zen detector for procedures in the cardiac EP laboratory
    Plank, F.
    Stowasser, B.
    Till, D.
    Hintringer, F.
    Schgoer, W.
    Stuehlinger, M.
    WIENER KLINISCHE WOCHENSCHRIFT, 2018, 130 : 133 - 133
  • [39] Patient peak skin doses from cardiac interventional procedures
    Zontar, D.
    Kuhelj, D.
    Skrk, D.
    Zdesar, U.
    RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 262 - 265
  • [40] Occupational radiation dose during fluoroscopy guided interventional procedures at Institut Kanser Negara
    Boharil, A.
    Hashim, S.
    Mustafa, S. N. M.
    18TH ASIA-OCEANIA CONGRESS OF MEDICAL PHYSICS (AOCMP) & 16TH SOUTH-EAST ASIA CONGRESS OF MEDICAL PHYSICS (SEACOMP), 2019, 1248