Skin dose to patients from interventional radiology and cardiology procedures with potentially long fluoroscopy times

被引:5
|
作者
Mooney, RB [1 ]
机构
[1] Forster Green Hosp, No Irland Reg Med Phys Agcy, Belfast BT8 4HD, Antrim, North Ireland
关键词
D O I
10.1093/oxfordjournals.rpd.a033100
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The increasing frequency and complexity of interventional procedures means that there is an increasing potential for the patient to suffer radiation-induced skin injuries. Dose measurements were initiated in a number of radiology, neuroradiology and cardiology departments in the Northern Ireland region which carry out interventional procedures with potentially long fluoroscopy times. The intention was to measure patient skin dose and thus estimate the likelihood of deterministic effects occurring from such examinations. For each patient, several thermoluminescence (TL) dosemeters were placed on the areas of sl;in the radiologist or cardiologist considered were most likely to receive the greatest irradiation. Results are presented which indicate that several types of procedure have the potential to produce deterministic effects to patients' skin. It was concluded that skin dose should be routinely measured for each patient undergoing an interventional radiology procedure which has potentially a long fluoroscopy time.
引用
收藏
页码:123 / 126
页数:4
相关论文
共 50 条
  • [1] The impact of pulsed fluoroscopy on patient skin dose in interventional radiology
    Angle, JF
    Hartwell, GD
    Spinosa, DJ
    Hagspiel, KD
    Leung, DA
    Matsumoto, AH
    RADIOLOGY, 2002, 225 : 252 - 252
  • [2] ESTIMATION OF PEAK SKIN DOSE IN INTERVENTIONAL CARDIOLOGY PROCEDURES
    Saaring, Juhan
    Kepler, Kalle
    MEDICAL PHYSICS IN THE BALTIC STATES, 2015, : 43 - 47
  • [3] A Direct Estimate of Peak Skin Dose for Interventional Fluoroscopy Procedures
    Weir, V.
    Zhang, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3368 - 3368
  • [4] Skin dose measurement for patients using imaging plates in interventional radiology procedures
    Ohuchi, Hiroko
    Satoh, Toshimitsu
    Eguchi, Yoichi
    Kaga, Yuji
    Arai, Takeshi
    Suzuki, Shin-ichi
    Yamadera, Akira
    HEALTH PHYSICS, 2007, 93 (01): : 78 - 86
  • [5] Patient skin dose in cardiac interventional procedures: Conventional fluoroscopy versus pulsed fluoroscopy
    Chida, Koichi
    Fuda, Kenji
    Saito, Haruo
    Takai, Yoshihiro
    Takahashi, Shoki
    Yamada, Shogo
    Kohzuki, Masahiro
    Zuguchi, Masayuki
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (01) : 115 - 121
  • [6] Patient Skin Reactions From Interventional Fluoroscopy Procedures
    Balter, Stephen
    Miller, Donald L.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (04) : W335 - W342
  • [7] Skin dose and dose-area product values for interventional cardiology procedures
    Vano, E
    Gonzalez, L
    Ten, JI
    Fernandez, JM
    Guibelalde, E
    Macaya, C
    BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (877): : 48 - 55
  • [8] Patient Radiation Doses in Interventional Radiology Procedures: Comparison of Fluoroscopy Dose Indices between the American College of Radiology Dose Index Registry-Fluoroscopy Pilot and the Radiation Doses in Interventional Radiology Study
    Jones, A. Kyle
    Wunderle, Kevin A.
    Fruscello, Tom
    Simanowith, Michael
    Cline, Brendan
    Dharmadhikari, Shalmali
    Duan, Xinhui
    Durack, Jeremy C.
    Hirschl, David
    Kim, Don-Soo
    Mahmood, Usman
    Mann, Steve D.
    Martin, Charles
    Metwalli, Zeyad
    Moirano, Jeffrey M.
    Neill, Rebecca A.
    Newsome, Janice
    Padua, Horacio
    Schoenfeld, Alan H.
    Miller, Donald L.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2023, 34 (04)
  • [9] Vendor-independent skin dose mapping application for interventional radiology and cardiology
    Krajinovic, Marko
    Krzanovic, Nikola
    Ciraj-Bjelac, Olivera
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (02): : 145 - 157
  • [10] Preliminary study of using imaging plates to map skin dose of patients in interventional radiology procedures
    Ohuchi, H
    Satoh, T
    Eguchi, Y
    Mori, K
    RADIATION PROTECTION DOSIMETRY, 2005, 117 (04) : 432 - 439