Skin dose to patients from interventional radiology and cardiology procedures with potentially long fluoroscopy times

被引:5
|
作者
Mooney, RB [1 ]
机构
[1] Forster Green Hosp, No Irland Reg Med Phys Agcy, Belfast BT8 4HD, Antrim, North Ireland
关键词
D O I
10.1093/oxfordjournals.rpd.a033100
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The increasing frequency and complexity of interventional procedures means that there is an increasing potential for the patient to suffer radiation-induced skin injuries. Dose measurements were initiated in a number of radiology, neuroradiology and cardiology departments in the Northern Ireland region which carry out interventional procedures with potentially long fluoroscopy times. The intention was to measure patient skin dose and thus estimate the likelihood of deterministic effects occurring from such examinations. For each patient, several thermoluminescence (TL) dosemeters were placed on the areas of sl;in the radiologist or cardiologist considered were most likely to receive the greatest irradiation. Results are presented which indicate that several types of procedure have the potential to produce deterministic effects to patients' skin. It was concluded that skin dose should be routinely measured for each patient undergoing an interventional radiology procedure which has potentially a long fluoroscopy time.
引用
收藏
页码:123 / 126
页数:4
相关论文
共 50 条
  • [11] Occupational Dose in Interventional Radiology Procedures
    Chida, Koichi
    Kaga, Yuji
    Haga, Yoshihiro
    Kataoka, Nozomi
    Kumasaka, Eriko
    Meguro, Taiichiro
    Zuguchi, Masayuki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (01) : 138 - 141
  • [12] Overall measurements of dose to patients in common interventional cardiology procedures
    Wang, Weipeng
    Zhang, Menglong
    Zhang, Yi
    RADIATION PROTECTION DOSIMETRY, 2013, 157 (03) : 348 - 354
  • [13] Patients' organ dose and risk assessment in interventional cardiology procedures
    Portugal, Maria
    Baptista, Mariana
    Vaz, Pedro
    Belchior, Ana
    RADIATION PHYSICS AND CHEMISTRY, 2022, 198
  • [14] Entrance skin dose measured with MOSFETs in children undergoing interventional radiology procedures
    Glennie, Diana
    Connolly, Bairbre L.
    Gordon, Christopher
    PEDIATRIC RADIOLOGY, 2008, 38 (11) : 1180 - 1187
  • [15] Entrance skin dose measured with MOSFETs in children undergoing interventional radiology procedures
    Diana Glennie
    Bairbre L. Connolly
    Christopher Gordon
    Pediatric Radiology, 2008, 38 : 1180 - 1187
  • [16] Skin dose assessment in interventional radiology
    Greffier, Joel
    Dabli, Djamel
    Frandon, Julien
    Beregi, Jean Paul
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 81 : 170 - 172
  • [17] Occupational eye dose in interventional cardiology procedures
    Haga, Yoshihiro
    Chida, Koichi
    Kaga, Yuji
    Sota, Masahiro
    Meguro, Taiichiro
    Zuguchi, Masayuki
    SCIENTIFIC REPORTS, 2017, 7
  • [18] Occupational eye dose in interventional cardiology procedures
    Yoshihiro Haga
    Koichi Chida
    Yuji Kaga
    Masahiro Sota
    Taiichiro Meguro
    Masayuki Zuguchi
    Scientific Reports, 7
  • [19] Comparison of four analogues of radiation dose for estimation of skin dose during interventional radiology procedures
    Fletcher, DW
    Miller, DM
    Balter, S
    Taylor, MA
    RADIOLOGY, 2000, 217 : 403 - 404
  • [20] Skin dosimetry of patients during interventional cardiology procedures in the Czech Republic
    Sukupova, Lucie
    Novak, Leos
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2008, 14 (04) : 217 - 225