Relative biological effectiveness for epithermal neutron beam contaminated with fast neutrons in the linear accelerator-based boron neutron capture therapy system coupled to a solid-state lithium target

被引:6
|
作者
Nakamura, Satoshi [1 ,2 ,3 ]
Imamichi, Shoji [2 ,4 ,5 ]
Shimada, Kenzi [6 ]
Takemori, Mihiro [1 ,2 ,7 ]
Kanai, Yui [2 ,4 ,8 ]
Iijima, Kotaro [1 ]
Chiba, Takahito [1 ,7 ]
Nakayama, Hiroki [1 ,7 ]
Nakaichi, Tetsu [1 ,2 ]
Mikasa, Shohei [1 ]
Urago, Yuka [1 ,7 ]
Kashihara, Tairo [9 ]
Takahashi, Kana [9 ]
Nishio, Teiji [3 ]
Okamoto, Hiroyuki [1 ]
Itami, Jun [9 ]
Ishiai, Masamichi [4 ]
Suzuki, Minoru [10 ]
Igaki, Hiroshi [2 ,9 ,11 ]
Masutani, Mitsuko [2 ,4 ,5 ]
机构
[1] Natl Canc Ctr, Div Radiat Safety & Qual Assurance, 5 1 1 Tsukiji, Chuo ku, Tokyo 1040045, Japan
[2] Natl Canc Ctr, Exploratory Oncol Res & Clin Trial Ctr, Div Boron Neutron Capture Therapy, 5 1 1 Tsukiji, Chuo ku, Tokyo 1040045, Japan
[3] Osaka Univ, Grad Sch Med, Div Hlth Sci, Med Phys Lab, 1 7 Yamadaoka, Suita, Osaka 5650871, Japan
[4] Natl Canc Ctr, Cent Radioisotope Div, 5 1 1 Tsukiji, Chuo ku, Tokyo 1040045, Japan
[5] Nagasaki Univ, Dept Mol & Genom Biomed, Grad Sch Biomed Sci, 1 7 1 Sakamoto, Nagasaki 8528588, Japan
[6] Canc Intelligence Care Syst Inc, 3 5 7 Ariake,Koto ku, Tokyo 1350063, Japan
[7] Grad Sch Human Hlth Sci, Dept Radiol Sci, 7 2 10 Higashiogu,Arakawa ku, Tokyo 1168551, Japan
[8] Tokyo Inst Technol, Inst Innovat Res, Lab Zero Carbon Energy, 2 12 1 Ookayama,Meguro ku, Tokyo 1525880, Japan
[9] Natl Canc Ctr, Dept Radiat Oncol, 5 1 1 Tsukiji, Chuo ku, Tokyo 1040045, Japan
[10] Kyoto Univ, Inst Integrated Radiat & Nucl Sci, 2 Asashiro Nishi, Kumatori cho, Osaka 5900494, Japan
[11] Tsukiji 5 1 1, Chuo ku, Tokyo 1040045, Japan
基金
日本学术振兴会;
关键词
neutron beam; solid-state Li target; relative biological effectiveness (RBE); accelerator-based BNCT system; boron neutron capture therapy (BNCT); RECURRENT HEAD; NECK-CANCER; B-10; BNCT; GLIOBLASTOMA; IRRADIATION; FACILITY; BRAIN;
D O I
10.1093/jrr/rrad037
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aimed to quantify the relative biological effectiveness (RBE) for epithermal neutron beam contaminated with fast neutrons in the accelerator-based boron neutron capture therapy (BNCT) system coupled to a solid-state lithium target. The experiments were performed in National Cancer Center Hospital (NCCH), Tokyo, Japan. Neutron irradiation with the system provided by Cancer Intelligence Care Systems (CICS), Inc. was performed. X-ray irradiation, which was assigned as the reference group, was also performed using a medical linear accelerator (LINAC) equipped in NCCH. The four cell lines (SAS, SCCVII, U87-MG and NB1RGB) were utilized to quantify RBE value for the neutron beam. Before both of those irradiations, all cells were collected and dispensed into vials. The doses of 10% cell surviving fraction (SF) (D10) were calculated by LQ model fitting. All cell experiments were conducted in triplicate at least. Because the system provides not only neutrons, but gamma-rays, the contribution from the gamma-rays to the survival fraction were subtracted in this study. D10 value of SAS, SCCVII, U87-MG and NB1RGB for the neutron beam was 4.26, 4.08, 5.81 and 2.72 Gy, respectively, while that acquired by the X-ray irradiation was 6.34, 7.21, 7.12 and 5.49 Gy, respectively. Comparison of both of the D10 values, RBE value of SAS, SCCVII, U87-MG and NB1RGB for the neutron beam was calculated as 1.7, 2.2, 1.3 and 2.5, respectively, and the average RBE value was 1.9. This study investigated RBE of the epithermal neutron beam contaminated with fast neutrons in the accelerator-based BNCT system coupled to a solid-state lithium target.
引用
收藏
页码:661 / 667
页数:7
相关论文
共 50 条
  • [31] Development of beryllium-based neutron target system with three-layer structure for accelerator-based neutron source for boron neutron capture therapy
    Kumada, Hiroaki
    Kurihara, Toshikazu
    Yoshioka, Masakazu
    Kobayashi, Hitoshi
    Matsumoto, Hiroshi
    Sugano, Tomei
    Sakurai, Hideyuki
    Sakae, Takeji
    Matsumura, Akira
    APPLIED RADIATION AND ISOTOPES, 2015, 106 : 78 - 83
  • [32] Optimization of target, moderator, and collimator in the accelerator-based boron neutron capture therapy system: A Monte Carlo study
    Cheon, Bo-Wi
    Yoo, Dohyeon
    Park, Hyojun
    Lee, Hyun Cheol
    Shin, Wook-Geun
    Choi, Hyun Joon
    Hong, Bong Hwan
    Chung, Heejun
    Min, Chul Hee
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (06) : 1970 - 1978
  • [33] Mixed-field dosimetry measurement of a target assembly for an accelerator-based neutron source for boron neutron capture therapy
    Reed, MK
    Dobelbower, MC
    Woollard, JE
    Blue, TE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 419 (01): : 160 - 166
  • [34] Mixed-field dosimetry measurement of a target assembly for an accelerator-based neutron source for boron neutron capture therapy
    Ohio State Univ, Columbus, OH, United States
    Nucl Instrum Methods Phys Res Sect A, 1 (160-166):
  • [35] Characterization of Be Deposits on Mo, W and Cu Substrates, to Implement in a Neutron Production Target for Accelerator-based Boron Neutron Capture Therapy
    Suarez Anzorena, M.
    Gagetti, L.
    del Grosso, M. F.
    Kreiner, A. J.
    INTERNATIONAL CONGRESS OF SCIENCE AND TECHNOLOGY OF METALLURGY AND MATERIALS, SAM - CONAMET 2013, 2015, 8 : 471 - 477
  • [36] Scalp angiosarcoma treated with linear accelerator-based boron neutron capture therapy: A report of two patients
    Igaki, Hiroshi
    Murakami, Naoya
    Nakamura, Satoshi
    Yamazaki, Naoya
    Kashihara, Tairo
    Takahashi, Akira
    Namikawa, Kenjiro
    Takemori, Mihiro
    Okamoto, Hiroyuki
    Iijima, Kotaro
    Chiba, Takahito
    Nakayama, Hiroki
    Takahashi, Ayaka
    Kaneda, Tomoya
    Takahashi, Kana
    Inaba, Koji
    Okuma, Kae
    Nakayama, Yuko
    Shimada, Kazuaki
    Nakagama, Hitoshi
    Itami, Jun
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2022, 33 : 128 - 133
  • [37] Monte Carlo simulation-based design of an electron-linear accelerator-based neutron source for boron neutron capture therapy
    Hiraga, F.
    APPLIED RADIATION AND ISOTOPES, 2020, 162
  • [38] Evaluating optimal quality assurance and quality control conditions of activation measurements at the accelerator-based boron neutron capture therapy system employing a lithium target
    Suzuki, Shunsuke
    Yagihashi, Takayuki
    Nitta, Kazunori
    Yamanaka, Masashi
    Sato, Naoki
    Gotoh, Shinichi
    Sugimoto, Satoru
    Shiba, Shintaro
    Nagata, Hironori
    Tanaka, Hiroki
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (04):
  • [39] Dependence of neutrons generated by 7Li(p,n) reaction on Li thickness under free-air condition in accelerator-based boron neutron capture therapy system employing solid-state Li target
    Nakamura, Satoshi
    Igaki, Hiroshi
    Okamoto, Hiroyuki
    Wakita, Akihisa
    Ito, Masashi
    Imamichi, Shoji
    Nishioka, Shie
    Iijima, Kotaro
    Nakayama, Hiroki
    Takemori, Mihiro
    Kobayashi, Kazuma
    Abe, Yoshihisa
    Okuma, Kae
    Takahashi, Kana
    Inaba, Koji
    Murakami, Naoya
    Nakayama, Yuko
    Nishio, Teiji
    Masutani, Mitsuko
    Itami, Jun
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 58 : 121 - 130
  • [40] Design of Beam Shaping Assembly for Accelerator-based Boron Neutron Capture Therapy and Study on Its Clinical Parameter
    Wang Y.
    Wang Z.
    Li N.
    Guan X.
    Gu L.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2022, 56 (07): : 1440 - 1447