Scalp angiosarcoma treated with linear accelerator-based boron neutron capture therapy: A report of two patients

被引:27
|
作者
Igaki, Hiroshi [1 ,2 ]
Murakami, Naoya [1 ]
Nakamura, Satoshi [2 ,3 ]
Yamazaki, Naoya [4 ]
Kashihara, Tairo [1 ]
Takahashi, Akira [4 ]
Namikawa, Kenjiro [4 ]
Takemori, Mihiro [3 ,5 ]
Okamoto, Hiroyuki [2 ,3 ]
Iijima, Kotaro [3 ]
Chiba, Takahito [3 ,5 ]
Nakayama, Hiroki [3 ,5 ]
Takahashi, Ayaka [1 ]
Kaneda, Tomoya [1 ]
Takahashi, Kana [1 ]
Inaba, Koji [1 ]
Okuma, Kae [1 ]
Nakayama, Yuko [1 ]
Shimada, Kazuaki [6 ]
Nakagama, Hitoshi [6 ]
Itami, Jun [1 ,2 ]
机构
[1] Natl Canc Ctr, Dept Radiat Oncol, Chuo Ku, Tsukiji 5-1-1, Tokyo 1040045, Japan
[2] Natl Canc Ctr, Div Res & Dev Boron Neutron Capture Therapy, Exploratory Oncol Res & Clin Trial Ctr, Chuo Ku, Tsukiji 5-1-1, Tokyo 1040045, Japan
[3] Natl Canc Ctr, Dept Med Phys, Chuo Ku, Tsukiji 5-1-1, Tokyo 1040045, Japan
[4] Natl Canc Ctr, Dept Dermatol Oncol, Chuo Ku, Tsukiji 5-1-1, Tokyo 1040045, Japan
[5] Grad Sch Human Hlth Sci, Dept Radiol Sci, Arakawa Ku, Higashi Ogu 7-2-10, Tokyo 1168551, Japan
[6] Natl Canc Ctr, Chuo Ku, Tsukiji 5-1-1, Tokyo 1040045, Japan
关键词
Boron neutron capture therapy (BNCT); Linear accelerator-based BNCT system; Solid-state Li target; First-in-human study; Scalp-angiosarcoma; AMINO-ACID TRANSPORTER-1; RADIATION-THERAPY; SYSTEM; RADIOTHERAPY; EXPRESSION; MELANOMA;
D O I
10.1016/j.ctro.2022.02.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This study reports the first-in-human use of a linear accelerator-based boron neutron capture therapy (BNCT) system and the first treatment of patients with scalp-angiosarcoma with accelerator-based BNCT. Patients and methods: A single-center open-label phase I clinical trial has been conducted using the system since November 2019. Patients with a localized node-negative scalp-angiosarcoma along with the largest diameter of the tumor <= 15 cm who refused primary surgery and chemotherapy were enrolled. After administration of boronophenylalanine (BPA), a single treatment of BNCT with the maximum dose delivered to the skin being 12 Gy-Eq was performed. The safety and effectiveness of accelerator-based BNCT therapy for localized scalp angiosarcoma were evaluated. Results: Scalp-angiosarcoma of the two patients did not develop the dose-limiting toxicity in the clinical trial. They reached CR within half a year and did not exhibit in-field failure 20 months after BNCT without any severe treatment-related adverse events. Although a grade 3 adverse event of an asymptomatic but increased serum amylase level was noted in both patients, it relieved without any treatment. Additionally, no severe acute dermatitis was observed for both patients, which is typically seen with conventional primary radiotherapy. Conclusions: It was suggested that BNCT would be a promising treatment modality for scalp-angiosarcoma, which is difficult to treat.
引用
收藏
页码:128 / 133
页数:6
相关论文
共 50 条
  • [1] Accelerator-based neutron source for boron neutron capture therapy
    Ivanov, A. A.
    Smirnov, A. N.
    Taskaev, S. Yu
    Bayanov, B. F.
    Belchenko, Yu, I
    Davydenko, V., I
    Dunaevsky, A.
    Emelev, I. S.
    Kasatov, D. A.
    Makarov, A. N.
    Meekins, M.
    Kuksanov, N. K.
    Popov, S. S.
    Salimov, R. A.
    Sanin, A. L.
    Sorokin, I. N.
    Sycheva, T., V
    Shudlo, I. M.
    Vorob'ev, D. S.
    Cherepkov, V. G.
    Fadeev, S. N.
    PHYSICS-USPEKHI, 2022, 65 (08) : 834 - 851
  • [2] Treatment Planning for Accelerator-Based Boron Neutron Capture Therapy
    Herrera, Maria S.
    Gonzalez, Sara J.
    Minsky, Daniel M.
    Kreiner, Andres J.
    VIII LATIN AMERICAN SYMPOSIUM ON NUCLEAR PHYSICS AND APPLICATIONS, 2010, 1265 : 451 - 452
  • [3] Acral cutaneous malignant melanoma treated with linear accelerator-based boron neutron capture therapy system: a case report of first patient
    Igaki, Hiroshi
    Nakamura, Satoshi
    Yamazaki, Naoya
    Kaneda, Tomoya
    Takemori, Mihiro
    Kashihara, Tairo
    Murakami, Naoya
    Namikawa, Kenjiro
    Nakaichi, Tetsu
    Okamoto, Hiroyuki
    Iijima, Kotaro
    Chiba, Takahito
    Nakayama, Hiroki
    Nagao, Ayaka
    Sakuramachi, Madoka
    Takahashi, Kana
    Inaba, Koji
    Okuma, Kae
    Nakayama, Yuko
    Shimada, Kazuaki
    Nakagama, Hitoshi
    Itami, Jun
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [4] Designing accelerator-based epithermal neutron beams for boron neutron capture therapy
    Bleuel, DL
    Donahue, RJ
    Ludewigt, BA
    Vujic, J
    MEDICAL PHYSICS, 1998, 25 (09) : 1725 - 1734
  • [5] Development of an Accelerator-Based Epithermal Neutron Source for Boron Neutron Capture Therapy
    S. Yu. Taskaev
    Physics of Particles and Nuclei, 2019, 50 : 569 - 575
  • [6] A shielding design for an accelerator-based neutron source for boron neutron capture therapy
    Hawk, AE
    Blue, TE
    Woollard, JE
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 1027 - 1031
  • [7] Development of an Accelerator-Based Epithermal Neutron Source for Boron Neutron Capture Therapy
    Taskaev, S. Yu.
    PHYSICS OF PARTICLES AND NUCLEI, 2019, 50 (05) : 569 - 575
  • [8] An accelerator-based epithermal photoneutron source for boron neutron capture therapy
    Mitchell, HE
    MEDICAL PHYSICS, 1997, 24 (12) : 2057 - 2057
  • [9] CURRENT RESEARCH ON ACCELERATOR-BASED BORON NEUTRON CAPTURE THERAPY IN KOREA
    Kim, Jong Kyung
    Kim, Kyung-O
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2009, 41 (04) : 531 - 544
  • [10] Design for an accelerator-based orthogonal epithermal neutron beam for boron neutron capture therapy
    Allen, DA
    Beynon, TD
    Green, S
    MEDICAL PHYSICS, 1999, 26 (01) : 71 - 76